TAC I/A Series 1 JACE 645 Series Network Controller

TAC I/A Series JACE 645 The TAC I/A Series™ JACE 645 Network Controller is a compact, embedded-processor platform with flash memory for backup. The JACE 645 provides integrated control, supervision, and network management solutions for a network of LonWorks™- based, BACnet-based, or -based controllers for building control. When connected over an Ethernet network, the JACE 645 can communicate and share data between LonWorks, BACnet, and Modbus systems. A complete set of Java™- based control, application, logging, and user interface “objects” are included in a library. With the Web User Interface Service, the system’s graphical views can be accessed using any standard Web browser, such as Microsoft Internet SPECIFICATIONS Explorer™ or Mozilla Firefox™.

Hardware Applications Dimensions Specifically designed for mechanical room, factory 9.75 in. W x 11.6 in. H x 2.5 in. D floor, and other commercial environments. The JACE 645 is wall-mounted, using its integral metal (248 mm x 295 mm x 64 mm) enclosure. Weight In a small building application, a single JACE can be 8.5 lbs (3.9 kg) with parts kit. used to support a network of BACnet, LonWorks, or 10 lbs (4.5 kg) as shipped. Modbus devices that can be accessed directly over the Ethernet LAN, or remotely over the Internet. Chassis The JACE 645 is a direct replacement for the UNC Mounting 520 and ENC 520 Series network controllers and Intended for indoor wall mounting only. When can be licensed to run in either an R2 or G3 Niagara mounting, add clearance of 2 in. (51 mm) at top and Framework application environment. Note that both bottom, and 1 in. (25 mm) on left and right sides. R2 and G3 environments cannot be active at the Construction same time and there is no R2 to G3 conversion tool. Steel chassis. Therefore, to migrate from R2 to G3 environments the entire application must be re-engineered including Cooling graphics. Internal air convection (vertical mounting required). Versions of the JACE 645 are available for retrofit PLATFORM applications that permit re-use of existing UNC/ENC power supplies and enclosures. Parts Microprocessor TRD-RB-645-R2 and TRD-RB-645 are retrofit boards Embedded PowerPC 440 Platform at 524 MHz. for the UNC 520 and ENC 520 Series controllers Memory respectively. 128 MB RAM, Optional 256 MB RAM (G3) 128 MB Flash for database backup. Operating System Operating System with IBM J9 Java Virtual Machine. (R2) or Sun Hotspot JVM (G3) Requires Niagara R2 2.301.535 or higher; or Niagara G3 3.6.47 or higher.

Specifications continued on next page. TAC I/A Series JACE 645 Series Enterprise Network Controller 2

Specifications continued from first page. Battery maintains processor operation through power failures for a predetermined interval, then writes all Backup data to flash memory, shuts processor down, and Battery backup. maintains clock for a minimum of 5 years. Clock Real-time clock. AGENCY listings electrical US Input Power Supply FCC Part 15, Class B TRD-T-645-R2, TRD-T-645 UL 916 • 120 Vac, 50/60 Hz, 25 VA max. Canadian • Lead wires for hot/neutral (wire nut), stud for UL Listed to Canadian Safety Standards ground connection. (CAN/CSA 22.2). No. 205-M 1983, “Signaling TRD-T-645-N Equipment.” RoHS Compliant. • 230 Vac, 50/60 Hz, 25 VA max. Australian • Terminal block for hot/neutral, stud for ground Meets requirements to bear the C-Tick Mark connection. European Community TRD-RB-645-R2, TRD-RB-645 EMC Directive 89/336/EEC, EN50081-1 (EMC Immu- • Existing UNC or ENC power supply. nity), EN50082-1 (AC Mains Power Line Voltage). Environment Communications Operating Temperature 32 to 122 °F (0 to 50 °C) • Two 10/100 Mbit Ethernet ports. RJ-45 connector. R2 applications limited to use of one Ethernet port. Shipping and Storage Temperature 32 to 158 °F (0 to 70 °C) • Four RS-485 ports (up to 76.8 Kbaud). Three- position screw terminal connectors, electrically Humidity isolated. 5 to 95% RH, non-condensing • Two RS-232 ports. RJ-45 connectors. Battery Backup • One LonWorks port – FTT-10A (up to 78 kbps). Battery Backup provided for all onboard functions. Two-pin Weidmuller connector, electrically isolated. Battery is monitored and trickle charged. Expected battery life is three years. In environments outside of recommended temperature range, battery life BACnet compliance expectancy is one year. BACnet Building Controller (B-BC).

FEATURES • Integral BACnet, BACnet/Ethernet, and BACnet MS/TP communications support.

• Integral LonWorks communications support. • Embedded RISC Microprocessor platform provides high computing speeds. • Distributes real-time data across an Ethernet LAN. • Provides alarming, logging, scheduling, control, and custom HVAC applications. • Password-protected access. BACnet is a registered trademark of ASHRAE. • Web User Interface supports many simultaneous ASHRAE does not endorse, approve, or test users over Intranet or Internet, via standard Web products for compliance with ASHRAE standards. browser. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BTL is a registered trademark of BI.

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl TAC I/A Series JACE 645 Series Enterprise Network Controller 3

MODELS Part Number Replaces Description TRD-T-645-R2 UNC-520-2 Network Controller with enclosure and 120 VAC, 25 VA power supply; includes R2 license

TRD-T-645 ENC-520-2 Network Controller with enclosure and 120 VAC, 25 VA power supply; includes G3 license

TRD-T-645-N ENC-520-2-N Network Controller with enclosure and 230 VAC, 25 VA power supply; includes G3 license

TRD-RB-645-R2 UNC-520-2 UNC-520-2-N Network Controller Retrofit Board for UNC 520; includes R2 license (Retrofit) TRD-RB-645 ENC-520-2 ENC-520-2-N Network Controller Retrofit Board for ENC 520; includes G3 license (Retrofit)

All non-retrofit models include the following: • Features: Web user interface, Enterprise Connectivity Pack (P2P) • Drivers: BACnet IP, BACnet over Ethernet, BACnet MS/TPa, LONworks, oBIX Client/Server and SSL For retrofits, all drivers and options active on the original UNC or ENC controller (where applicable) will be transferred to the replacement board. Memory expansion is NOT included in the base unit. Retrofit upgrade of an ENC-520 with 256 RAM will also require the purchase of the TRD-NPM-256 memory expansion option. a. TRD-T-645-R2 includes one trunk of BACnet MS/TP. Additional trunks can be purchase as IA-DRV-MST-P.

r2 only options Part Number Description TRD-R2-6XX Add R2 application license to TRD-T-603 (-N) or TRD-T-645 (-N) network controller

TRD-R2-RB-6XX Add R2 application license to TRD-RB-603 or TRD-RB-645 network controller (retrofit board) IA-DRV-ASD ASD device driver for direct ASD Bus support; includes tunnel support for XPSI IA-DRV-DMS-E DMS serial device driver; includes tunnel support for OPRIF IA-DRV-MS31 MicroSmart device driver; for direct MicroSmart Bus support of 31 controllers on a single trunk; includes tunnel support for OPRIF Level 9/10/11 firmware supported. IA-DRV-MS62 MicroSmart device driver; same as above but supports 62 controllers IA-DRV-MS93 MicroSmart device driver; same as above but supports 93 controllers IA-DRV-MS124 MicroSmart device driver; same as above but supports 124 controllers IA-DRV-LCM Local Control Module (LCM) device driver; supports up to 31 LCMs on a single network IA-DRV-MST-P BACnet MSTP device driver; direct BACnet MSTP support IA-DRV-MOD Modbus device driver; direct Modbus support IA-DRV-MOD-S Modbus slave device driver; Modbus slave using RTU protocol IA-DRV-MOD-T Modbus Client device driver; Modbus TCP support; Modbus client, using Ethernet TCP IA-DRV-MOD-R Modbus Server device driver; Modbus TCP support; Modbus server using Ethernet TCP IA-DRV-NW8-E NETWORK 8000 serial device driver; includes tunnel support for XPSI IA-DRV-SNM-P Simple Network Management Protocol (SNMP) driver

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl TAC I/A Series JACE 645 Series Enterprise Network Controller 4 g3 only options Part Number Description TRD-G3-6XX Add G3 application license to TRD-T-603-R2 or TRD-T-645-R2 network controller

TRD-G3-RB-6XX Add G3 application license to TRD-RB-603-R2 or TRD-RB-645-R2 network controller (retrofit board) TRD-NPM-256 Upgrade RAM license 128 to 256 MB – Increases JAVA heap 48MB to 96MB (G3 stations only) ENC-DRV-ASD ASD device driver for direct ASD Bus support; includes tunnel support for XPSI ENC-DRV-DMS DMS serial device driver; includes tunnel support for OPRIF ENC-DRV-ILON Driver for LON over IP using CEA-852; communicates through an IP/LON router ENC-DRV-EIB EIB/Konnex IP driver designed to connect to an EIB/KNX network via an IP to EIB interface ENC-DRV-FLEX Configurable Flex driver, over RS-232 or RS-485 ENC-DRV-MBUS Manages an M-Bus network via an RS-232 to M-Bus interface Enables SMS alarms to be sent to any mobile phone via a GSM/GPRS modem connected to the RS-232 ENC-DRV-SMS serial port MicroSmart device driver. For direct MicroSmart Bus support (see Note below). Includes tunnel support ENC-DRV-MS for OPRIF; Level 9/10/11 firmware supported. ENC-DRV-MOD Modbus device driver; direct Modbus support ENC-DRV-MOD-S Modbus slave device driver; Modbus slave using RTU protocol ENC-DRV-MOD-T Modbus Client device driver; Modbus TCP support; Modbus client, using Ethernet TCP ENC-DRV-MOD-R Modbus Server device driver; Modbus TCP support; Modbus server using Ethernet TCP. ENC-DRV-NW8 NETWORK 8000 serial device driver; includes tunnel support for XPSI ENC-DRV-SNMP Simple Network Management Protocol (SNMP) driver ENC-WB Embedded workbench tool IA-LIC-G3-UPG1 Software upgrade for ENC / JACE

accessories Part Number Description UNCC-405 RJ-45 socket to DB-9 socket adapter, null modem UNCC-430 RJ-45 socket to DB-25 plug adapter, straight through CBL-RJ45-4 Flat silver satin cable, 4ft CBL-RJ45-10 Flat silver satin cable, 10ft E24-1555-2 LON (LonWorks) Trunk Connector Plug, 2-position E24-1576-3 RS-485 connector plug, 3-position UNC-400-BAT Battery, 12 Vdc, 1.2 AH

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl TAC I/A Series JACE 645 Series Enterprise Network Controller 5

Architecture

Internet Remote Browser User Interface

Ethernet, TCP/IP, BACnet, XML, HTTP

JACE 645 JACE 645 Web Browser Network Network Controller Controller

FTT-10A RS-485

TAC I/A Series Enterprise Network Server

Access s Controller s

I/A TAC I/A Series MicroNet Series MN 800 ® Bu BACnet MNB-1000 Plant Controller Field Field TAC I/A Series MicroNet

ORKS MN 800 Controller W ON L TAC I/A Series MicroNet 1 BACnet MNB-300 TAC I/A Series MicroNet Unitary Controller LONMARK™ Certified

BACnet MS/TP Communications Bu S-Link Sensor VAV Series Controller

1 TAC I/A Series MicroNet TAC I/A Series MicroNet LONMARK Certified BACnet MNB-V1, MNB-V2 MN 100, MN 150, VAV Controller or MN 200 Controller

1 The TAC I/A Series MicroNet LONMARK certified controllers are interoperable controllers designed in accordance with LONMARK guidelines.

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl TAC I/A Series JACE 645 Series Enterprise Network Controller 6

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl TAC I/A Series JACE 645 Series Enterprise Network Controller 7

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl TAC I/A Series JACE 645 Series Enterprise Network Controller 8

Distributed and sold by Schneider Electric. I/A Series trademarks are owned by Invensys Systems, Inc. and are used on this product under master license from Invensys. Invensys does not manufacture this product or provide any product warranty or support. For service, support, and warranty information, contact Schneider Electric. All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. All rights reserved.

Schneider Electric | Buildings www.schneider-electric.com/buildings 1-888-444-1311 Schneider© 2013 Electric. All rights reserved. F-27842-1 November 2013 tl