Uniclass L7534 EPIC L32

Cl/SfB (57)

2008/9 Ventilation solutions for domestic, commercial and light industrial applications Xpelair Always the Freshest Solutions

For over fifty years, Xpelair has been designing and manufacturing ventilation solutions for domestic, commercial and industrial applications.

2 Over 50 years Xpelair has earned an enviable reputation in world-class domestic, commercial and industrial ventilation leading the way with innovative technologies and style to ensure the air we breath is clean, fresh and healthy. Xpelair products are specified and distributed in over 80 countries, their ease of installation and reliability gaining many international Government contracts and firmly retaining their position as the specifier's choice.

Today, the Xpelair range addresses the issues of safety in the home, air tight buildings, energy efficiency, and the need to remove carbon emissions with intelligent products to meet specific needs. The range anticipates forthcoming building regulations, environmental legislation and changing construction methods.

Xpelair's dedicated specification team is ready to provide field applications advice and work with installation providers to ensure fast and hassle-free installation. If you prefer, a design service is also available to provide a specification from your plans. All our product information is available on-line. Advice is only a phone call away.

Sustainable building solutions from Xpelair. s

Tel: 08709 000420 n o i t u l o

Xpelair presents CarbonLite: S

Working to lighten the impact on our planet’s resources. t s e As part of Applied Energy, Xpelair takes a responsible And consider our range of energy saving auto-controls h approach to the design, manufacture, packaging and designed to respond to the changing without s specification of its products, actively seeking ways to improve the need for occupant intervention. e

with the environment in mind. r With over 90% of our product assembly still in the UK Xpelair F In this year’s catalogue you will find many products bearing is proud of its record in minimising transport pollution.

the CarbonLite symbol indicating our use of UltraDC and And we have removed all EPS from our packaging which is e UltraEC technology, significantly lowering energy use and bio-degradable. h

extending motor life to beneficially reduce ‘whole life costs’. t XRA and XMV roof cowls are now 100% recyclable. Lightening the weight of CO2 emissions in manufacture and You will find products from our Xcell and Xplus ranges are the home is everybody’s responsibility. The CarbonLite s now Appendix Q ‘Best Practice’ listed for inclusion in initiative is our small contribution. y SAP calculations. a w Ventilation is essential to health and the protection of the l

fabric of a building but over-ventilating can lose valuable heat. A

Choose from our domestic products providing the installed r ventilation requirements of Building Regulations Part F1. i a l e p

www.xpelair.co.uk 3 X

Product Contents

Bathroom and Shower Rooms

NEW NEWNEW NEW

DX180 DX200/ LVDX200 LVCF20 LVCF20T DC CF20/40T Profile DX100 XX100 CF20 (UltraDC) (UltraCV) 29/25M

Page Number 12 12 14 14 16 18 20 22 22 Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Flat Ducting Axial Axial

NEW NEW

LV100 SL100 CentrX XIL XXS BriteX BriteX Turbo XIM

Page Number 24 26 28 30 30 32 32 34 Fan Type Axial Axial Centrifugal Axial Axial Axial Mixed Flow Mixed Flow

Kitchens

NEW NEW NEW NEW NEW NEW

GX6/ DX400/ CF20/40T SL150GX6 GXC6 GX6 EC2 GXC9 CF40 (UltraCV) Canopies Profile 60 CX10 CMF

Page Number 38 40 42 40 44 46 48-51 52 54 54 Fan Type Axial Axial Axial Axial Centrifugal Centrifugal Centrifugal Flat ducting Axial Centrifugal

For Domestic Sensors, Switches & Accessories see pages 56 - 59

4 Home Systems

NEW NNEWEW NEW

Xplus Xplus 250 & 400 Xcell Profile 150 System X EverDri XHR150 AutoFlow

Page Number 62 64 66-75 76 78 82 84 86 Type Mechanical Mechanical Mechanical System ducting Ducting system Positive Input Mechanical Passive Extract Extract Ventilation Ventilation (PIV) Ventilation Air-input Ventilation (MEV) Ventilation (MEV) and Heat and Heat Recovery (MVHR) Recovery (MVHR)

Commercial Ventilation

GX PX RX WX WXXL ChefX

Page Number 90 92 94 96 98 100 Fan Type Axial Axial Axial Axial Axial Kitchen Canopies For Commercial Sensors, Switches & Accessories see pages 100 - 103 Heating and Air Treatment

Screen Electrostatic DigitempWH & WHP DCHPlinthHeat Heat Whispair Air Cleaners DigiPure

Page Number 108 110 112 112 114 116 118 120 Type Air Fan heater Plinth Over door Circulation Air cleaner Air cleaner conditioner heater heater fan

Industrial Ventilation

Scimitar XPMS Scimitar XSCS Rapier XPMA Rapier XSCA Rapier XRA XMV XID

Page Number 124 126 128 130 132 134 136 Fan type Plate mounted Short case Plate mounted Short case Roof fan Mixed flow Metal inline axial axial axial axial & cowl roof s t n NEW NEW NEW NEW e t n o

XIDPXpress MinimX C LoSound C CubeX C HiFlo CMAX ManCoolers C t

Page Number 138 142 144 146 148 150 152 c Fan type Plastic inline Mixed flow Compact Attenuated Versatile Attenuated Air circulation inline inline inline attenuated inline Inline u d

For Industrial Controllers & Accessories see pages 154 - 159 o r

www.xpelair.co.uk 5 P

Domestic Ventilation

Home Comfort

Home comfort has come a long Intermittent Ventilation Requirements Correct siting way in the last two decades. New build The extract point should always be sited The minimum domestic mechanical to capture water vapour and odours at The design and construction methods of ventilation requirements are*: source. It should be located as high as domestic buildings have changed radically. • Kitchens 60 l/s (30 l/s with a possible and provide a flow across the Room sizes and room heights have cooker hood) room with air replacement usually generally decreased and the envelope of • Utility rooms 30 l/s coming from the doorway. If there is a the building is better sealed and insulated. • Bath/shower rooms 15 l/s negligible gap beneath the door when Add a new generation of furnishing and • Separate toilets 6 l/s closed, fit a slimline door at low flooring materials, security and our • In addition, rooms without windows level for air replacement and effective changing lifestyles and we find that our must have an overrun timer of at least fan operation. homes are sealed up for prolonged 15 minutes periods unable to breathe naturally like * assumes that fans are running only when If there is a fuel burning appliance in the previous generations of ‘leaky’ homes. rooms are in use. room, ensure that there is adequate air replacement for both the fuel burning We are cosier and more energy efficient, Refurbishment appliance and the fan. Finding the right which is good for our pockets as well as Older properties present a different position can often be a compromise. the environment. But an average family challenge. With generally larger rooms, In an upstairs bathroom, options will produces about two gallons of water higher ceilings but poorer insulation, the include a ceiling mounted fan with vapour a day from breathing, washing, effects of condensation are often more ductwork running to a soffit grille or fan cooking in addition to a build up of odours. obvious. Here, a better method of and light such as Xpelair BriteX. selecting a fan is based on the volume of Indoor pollution is not just bad for the the room multiplied by the following air Axial or Centrifugal? building fabric, it can affect our health too. change rates. So, we know the volume of air to be Bronchial conditions can be triggered by • Domestic kitchens 15-20 ach extracted per hour and if it is wall, the house dust mite that thrives in warm • Bathrooms 6-10 ach window or ceiling fitting. Axial fans such moist conditions. • Shower rooms 15-20 ach as Xpelair DX100 are most appropriate for extraction directly to the outside Building Regulations • Toilets 6-10 ach through a wall or window. However, if the The Building Regulations Part F1 is a legal • Utility rooms 15-20 ach window or wall faces a prevailing wind requirement requiring adequate ventilation in buildings intended to be ‘capable of Example: An older style kitchen 2.5m by such as in coastal areas, exposed hills restricting the accumulation of such 4m with a ceiling height of 3m will have a or high rise applications, a centrifugal moisture, which could lead to mould growth volume of: 2.5x4x3 = 30 cubic metres. fan which has a higher pressure and pollutants originating from within the performance is more suited to overcome Air change rate is 15-20 building as would become a hazard to the these outside conditions. 30x15 = 450 m3/h health of people in the building.’ 30x20 = 600 m3/h Centrifugal fans are ideal for flexible The Building Regulations 2006 Edition ducted applications or smooth bore recognises the importance of ventilation in Here a GXC9 with an extract ducting for longer distances. Choose an 3 buildings, requiring ventilation for kitchens, performance of 549m /h would Xpelair Premier DX200T model with timer utility rooms, bath/shower rooms, be appropriate. for internal toilets, bathrooms and combined bathroom/toilets and washrooms with no direct access to the commercial applications. outside to meet Part F1 requirements.

6 Where do I need a fan with Continuous Wholehouse Ventilation The Appendix Q website lists MVHR and control? In many new build situations, architects MEV units listed meet the Best Practice as Automatic humidity control is there for are choosing ducted whole-dwelling defined by GPG 268 published by the your convenience and to protect you and systems such as Xpelair’s Xplus central Energy Saving Trust. extract range. Approved by Building your home from unhealthy levels of Regulations Part F1, this continuously condensation, particularly when the users So whatever the season the result is a extracts from several rooms where comfortable but well aired home that of the room can not always be relied moisture may be generated throughout upon to switch On the fan. Auto controls the day and night, at a low air change always feels ‘fresh’. save energy by only switching the fan On rate, with a boost speed triggered when necessary. All Xpelair domestic automatically by a sensor or condensation control fans are supplied operated manually. with built-in humidistats. These require only one opening to the If the fan cannot be located near the outside which is important where sound source of humidity, then a separate issues and external visual impact remote is available. are relevant. Alternatively Premier Ultra DC units can be used to provide a SELV (Safety Extra Low Voltage) fans decentralised wholehouse extract system Bathrooms and showers are areas of with heat recovery. increased electrical hazard as defined by the IEE Wiring Regulations (16th Edition) Wholehouse Ventilation BS 7671: 2001 In tight, well insulated, new dwellings, Mechanical Ventilation with Heat Recovery What does it all mean? like the Xpelair Xcell range is increasingly When fitting ventilation products in Zones 1 being used as a state of the art solution. and 2, a water ingress protection rating of MVHR combines wholehouse ventilation IPX4 or higher is required for the installed based air changes rates given in Part F1 product. It is essential that the electrician tables 1.1a and 1.1b with a high efficiency also maintains IPX4 integrity at the cable

heat recovery cell. The unit simultaneously n entry. Most Xpelair DX100 and Premier

extracts air from the wet areas: kitchen, o products are tested to IPX5 which i

utility rooms, bathrooms and toilets, which t exceeds this.

passes through the cell in one direction a l

warming incoming filtered air from outside, i

For complete peace of mind a range of t which is then distributed to other parts of

Xpelair DX100 SELV and Premier SELV n the home. The heat recovery rate is fans fulfil the requirements of IPX5. They e exceptional (typically 90%) and UltraDC

operate on a 12V system with a SELV V transformer located outside Zone 2. motors ensure very low running costs. c i

The illustrations in the Bathroom Zoning t

section show the zones in which fans of s

differing IP rating can be installed. e m o

www.xpelair.co.uk 7 D

Bathroom Zoning

Bath/shower rooms are areas Zone 1 - is limited by: Zone 3 - is limited by: of increased electrical hazard. 1. The upper plane of Zone 0 and the 1. The vertical plane(s) external to Zone 2 horizontal place 2.25m above the and parallel vertical plane(s) 2.4m When fitting ventilation products in Zones floor, and external to Zone 2, and 1 and 2 of a bath/shower room, an ingress protection rating of at least IPX4 is 2a.By the vertical plane(s) circumscribing 2. The floor and the horizontal plane required, in accordance with the the bath tub or shower basin and 2.25m above the floor. requirements of the IEE Wiring Regulations includes the space below the bath tub (16th Edition) BS 7671:2001. The following or shower basin where that space is In addition, where the ceiling height guide will assist specifiers and installers accessible without the use of a tool, or exceeds 2.25m above the floor, the space with the selection and positioning of above Zone 2 up to the ceiling or a height suitable electrical products in this area. If 2b.For a shower without a basin and with or 3.0m above the floor whichever is lower, in doubt consult the standard. a demountable shower head able to is Zone 3. Extract from BS7671:2001 move around in use, the vertical plane(s) at a radius of 1.2m from the 601-02 Classification of Zones water outlet at the wall, or

601-02-01 These requirements are based 2c.For a shower without a basin and with on the dimensions of four zones: Zone 0, a shower head which is not Zone 1, Zone 2 and Zone 3. The zones demountable, the vertical plane(s) at a are determined taking account of walls, radius 0.60m from the shower head. doors, fixed partitions, ceilings and floors, where these effectively limit the extent of a Note: Electrical appliances should be either zone. Figures 601A and 601B are IPX4 rated or Safety Extra Low Voltage. examples of the zones.

Zone 0 - is the interior of the bath tub Zone 2 - is limited by: or shower basin. 1. The vertical plane(s) external to zone 1 In a location containing a shower without a and parallel vertical plane(s) 0.60m basin, Zone 0 is limited by the floor and by external to Zone 1, and the plane 0.05m above the floor. In this case: 2. The floor and the horizontal plane 1. Where the shower head is demountable 2.25m above the floor. and able to be moved around in use Zone 0 is limited by the vertical In addition, where the ceiling height plane(s) at a radius of 1.2m horizontally exceeds 2.25m above the floor, the from the water outlet at the wall, or: space above zone 1 up to the ceiling or a height of 3.0m above the floor whichever 2. Where the shower head is not is lower, is Zone 2 demountable, Zone 0 is limited by the vertical plane(s) at a radius of 0.60m Note: Most electrical installations fall within from the shower head. this Zone. Electrical appliances should be either IPX4 rated or Safety Extra Low Note: Electrical appliances will require an Ingress Protection IPX7 rating, which Voltage. means the product must be capable of temporary immersion in water.

8 s n o i t a l l a t s n i g n i l i e

Typical Examples of Zoning c

Bath only Shower without Tray (with permanently fixed d

partition - fixed water outlet not demountable) n a w o d n i w , l l a w r o f s n a f Shower with Tray Shower without Tray (with permanently fixed partition - water outlet demountable) m o o r r e w o h s d n a m o o r h t a

www.xpelair.co.uk 9 B Bathroom and Shower Rooms Fans for wall, window and ceiling installations

More moisture is produced in The solution is to extract moisture and Axial fans are suitable for through the odours at source. In bathrooms and wall or window fitting in most homes. bathrooms than anywhere toilets the most effective position is For high-rise and exposed (e.g. coastal) else in your home. diagonally opposite the door allowing a locations, centrifugal fans will cope better gentle flow of air across the room. In with gusty conditions. Centrifugal and Bathrooms and shower rooms are showers, it is often best positioned mixed flow units have a better pressure relatively cool areas. Moisture from hot directly over the shower cubicle. characteristic, which makes them more water when showering, bathing and suitable where a ducted solution is washing is quickly absorbed into the air, Which solution is best for me? required. For showers, Xpelair offers kits IEE electrical regulations define which warms rapidly increasing further its for simple above ceiling extract ventilation bathrooms as areas of increased capacity to hold water vapour. The hard through a soffit. electrical hazard. The illustrations in the surfaces of the bathroom – tiling, mirrors, Bathroom Zoning section show the zones Air replacement is particularly important painted surfaces and windows change in which fans of differing IP rating can be in these rooms as the doors are shut temperature far more slowly and, being installed. As a rule, look out for IPX4 or when occupied. A fan can only function if cooler than the air, form water droplets higher. For complete peace of mind there is an equal flow of air to that being seen as ‘misted up‘ mirrors and windows. Xpelair LoVolt models are available which extracted. This can be achieved by have a separate Safety Extra Low Voltage maintaining a small gap beneath the door This warm ‘wet’ air quickly migrates to transformer fitted outside of the splash and the floor covering or by fitting a slim adjacent rooms condensing on cooler area and operate the fan at 12Vac. air replacement grille to the door. unventilated surfaces such as the back of wardrobes and increasing the humidity For installations that fall within the scope level throughout the house. of Building Regulations the extract requirements are 15 l/s for bathroom and Matters can be aggravated if the room is shower rooms, and 6 l/s for toilets. also used for drying clothes. If the room does not have an opening Today, condensation problems like these window then a fan with a built in timer are more commonplace as we shower should be selected. This will continue to more and place greater emphasis on air run for at least 15 minutes after the room tightness in our homes. has been vacated.

Toilets present a different problem. For other rooms where moisture Unchecked, odours are unpleasant generation is high a humidity sensor and embarrassing. controlled fan would be recommended.

10 s n o i t a l l a t s n i g n i l i e c Bathroom and Shower Rooms d

NEW NEWNEW NEW n a w o

DX200/ LVDX200/ LVCF20T DC CF20/40T Profile d DX180 DX100 XX100 CF20 LVCF20 (UltraDC) (UltraCV) 29/25M n i Page Number 12 12 14 16 18 20 22 22 Fan Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Flat Ducting Axial Axial w

Voltage 230V 230V 230V Ultra DC Ultra DC n/a 230V 230V , l

Positioning Wall / Window Wall / Window Wall / Window Wall / Window Wall / Window n/a Wall / Window Wall / Window l Max extract rate (m3/h) 94 108 108 54 216 n/a 76 76 a IP rating IPX4 IPX5 IPX5 IPX5 IPX5 n/a IPX5 IPX5

Fan only or kit Fan Fan Fan Fan Fan n/a Kit Fan w Fan only or kit Fan Fan Fan Fan Fan n/a Kit Fan r Carbonlite nn o f

NEW NEW s n a f m

LV100 SL100 CentrX XIL XXS BriteX BriteX Turbo XIM o o

Page Number 24 26 28 30 30 32 32 34 r

Fan Type Axial Axial Centrifugal Axial Axial Axial Mixed Flow Mixed Flow r

Voltage LoVolt 230V 230V 230V 230V LoVolt LoVolt 230V e Positioning Wall / Window Wall / Window Wall Inline Inline Inline Inline Inline Max extract rate (m3/h) 85 218 169 133 85 56 65 845 w

IP rating IPX5 IPX4 IPX4 IPX2 IPX2 IPX4 IPX4 IPX2/4 o

Fan only or kit Kit Fan Fan Kit Fan Kit Kit Fan h s d n a m o o r h t a

www.xpelair.co.uk 11 B

Xpelair Premier DX180, DX200 & CF20 Centrifugal extract and condensation control fans

DX180DX200 CF20

Key features The Range

Application: Suitable for surface, The efficient and stylish Premier range air operated back draught shutter and flush wall and ceiling of pressure developing fans is the CF20 range are supplied with a mounting. designed specifically for domestic brown 100mm external outlet grille for Window kit available applications, including bathrooms, wall or soffit fixing. shower rooms, toilets and utility rooms where longer runs are required. The clip off front cover and removable Control options: Pullcord, timer and fan blade on all models allow easy humidistat They are also suitable for commercial applications such as hotel rooms, cleaning and maintenance. All also office toilets, commercial bathrooms have a neon indicator (except DX180/T). Legislation: Conforms to Building and for coastal installations. DX200 and CF20 models are IPX5 Regulations Part F1 All models have a gloss white casing rated where-as the DX180 models are with clean and sleek appearance. IPX4. All are BEAB approved. They are Hole diameter: 117mm (wall/ceiling) A two part casing means Premier fans all suitable for 220-240V AC 50Hz 120mm (window) can easily be recessed or surface mains operation. Motors are totally mounted. They can be fitted into enclosed and maintenance free for life, ceilings or stud work walls in recesses with self aligning bearings and a as little as 50mm deep using the side thermal cut-out. All electronics and entry knockout provided, an FDA wiring terminals are fully protected. adaptor and Profile 29 flat duct. Optional filter is available. Alternatively 100mm circular ducting See page 57. can be used. All feature an automatic Select the right product for your application

DX180 DX180T DX180H DX200 DX200T CF20 CF20T Reference number 91181AW 91182AW 91183AW 91013AW 91014AW 91015AW 91016AW Remote switch (supplied separately) nn n n n Integral pullcord nn Integral adjustable run-on timer (30s to 20 mins) nn Integral fixed run-on timer (20 mins) n Humidity sensor (50-90% RH) n n n Quick visit facility (2 minutes) nn Speeds 1 1 1 2 4 5 5 Trickle ventilation facility nnn Extract performance (FID, m3/h) boost - - - - - 108 108 speed 3 - - - - 108 102 102 speed 2 - - - 108 79 79 79 speed 1 94 94 94 50 50 50 50 trickle - - - - 36 36 36 Extract performance (FID, l/s) boost - - - - - 30 30 speed 3 - - - - 30 28 28 speed 2 - - - 30 22 22 22 speed 1 26 26 26 14 14 14 14 trickle - - - - 10 10 10 Sound pressure level (dB(A)@3m) boost - - - - - 50 50 speed 3 - - - - 50 48 48 speed 2 - - - 50 42 42 42 speed 1 49 49 49 32 32 32 32 trickle - - - - 26 26 26 Max. electrical power rating (W) 26 26 26 34 34 34 34 IP rating IPX4 IPX4 IPX4 IPX5 IPX5 IPX5 IPX5 Weight (kg) 2.0 2.0 2.0 1.75 1.75 1.75 1.75 Guarantee (years, UK) 3 3 3 3 3 3 3

12 Models Controllers

Premier DX180 • ‘QuickVisit’ delay feature prevents fan from Manual Override Switch MOS Ref. 91181AW running should light be switched On/Off Ref. 90199AW • Single speed centrifugal unit again within 2mins • Switch 1 controls the high/low speed levels and

• Operated by remote switch or sensor • Mechanical trickle ventilation facility • Switch 2 controls On/Off and the tricklevent s

• Built-in run-on period after light switched option n

Premier DX180T Off. User adjustable from 30s-20mins a Ref. 91182AW Remote Humidistat XRH f Ref. 21856AW l • Single speed centrifugal unit with timer Premier CF20 • Stand alone humidistat switches fan On/Off o

• Built-in fixed 20mins run On period after the Ref. 91015AW r

when RH reaches pre-set levels. Complete t light has been switched Off • High performance condensation control with pullcord override switch n centrifugal unit o Premier DX180H • Step-speed, user adjustable humidistat Remote Time Delay Unit DT20B c Ref. 91183AW • Room size selector matches extract Ref. 21850AW

• Single speed centrifugal unit with humidistat performance for improved efficiency • User adjustable run-on timer (2-20mins) n

• On/Off humidistat adjustable 50-90% RH o

• Tricklevent and Pullcord manual override i

Passive Infrared Sensor XPIRA t • Includes external wall grille

Premier DX200 Ref. 21871AA a

Ref. 91013AW Premier CF20T • Activates fan via body movement. Ideal for s • High performance centrifugal unit Ref. 91016AW infrequently used public spaces. Built in n

timer to prevent nuisance tripping e • Choice of 2 set speeds • All the features of CF20 plus: d Premier DX200T • Auto run-on after light switched Off n Ref. 91014AW • ‘QuickVisit’ delay feature prevents fan from Typical Specifications on page 160. o running should light be switched On/Off Wiring Diagrams on page 180. • High performance centrifugal unit with timer c • Room size selector matches extract again within 2 mins Remote Sensors on page 56. performance for improved efficiency d n

Performance a t DX180 Range DX200 Range DX200T/CF20 c a r t x e l a g u f i r t n e C |

Dimensions (mm) 0 2

Premier DX180 Premier DX200 Premier CF20 F C

100 100 100 100 & 0 0 2 X Installation and Accessories D , 0 8 1 X D r e

Wall Mounting Flush Wall Mounting Ceiling Mounting Flush Ceiling Surface Ceiling Window Mounting i with flat ducting Mounted Mounted m

Hole diameter: 117mm Hole diameter: 117mm or (w233 x h203mm flush mounted) Hole diameter: 120mm e r

Installation Accessories Installation Accessories Installation Accessories P r

Wall vent kit VK10 Ref. 89120AW Flat ducting XFP see Profile 29 Glass mounting kit GMK i

Termination ducting kit WT Ref. 89538AA Flexible ducting FD100 Ref. 89910AA Ref. 90546AA a

Wall tube WD100 Ref. 89543AA Condensation trap XCT100 Ref. 89749AA l

Easy fit kit EFT Ref. 90427AA Vent cowl VC10 Ref. 89531AA e Flat duct adaptor FDA Ref. 90547AA p Ceiling mounting adaptor XCMK Ref. 90066AA 13 X Xpelair Premier LoVolt LVDX200 & LVCF20 Safety Extra Low Voltage ventilation

LVDX200 LVCF20

Key features The Range

Application: Domestic bathrooms, Splash about with complete peace of Class B making them suitable for shower rooms, toilets mind. The Safety Extra Low Voltage ambient temperatures up to 40ºC. and utility rooms (SELV) versions of the Premier DX200 and CF20 pressure developing Premier SELV fans have the same centrifugal fans are ideal for use in clean and sleek styling as the rest of Control options: Pullcord, timer & shower rooms, bathrooms with the Premier range, with a white gloss humidistat showers and other zone 1 and zone 2 body and fascia. They are designed for wet areas. The SELV system consists of easy installation in walls, ceilings, a 12V fan unit which can be safely windows or ducted installation at any Legislation: Conforms to Building installed in the spray area of a bath or angle, and LVCF20 models come Regulations Part F1 shower, with the transformer located complete with a brown 100mm grille outside the spray area. for wall or soffit fixing. All models come Hole diameter: 117mm (wall/ceiling) complete with a universal mounting kit Premier models LVDX200 & LVCF20 and an automatic backdraught shutter. 120mm (window) conform to Building Regulations covering mechanical ventilation for The two part casing permits recessed toilets, bathrooms and utility rooms. or surface mounting, and can be fitted Importantly they exceed the IP into ceilings and studwork wall requirements for zone 1 and zone 2 as recesses as little as 50mm deep using defined by IEE Wiring Regulations the top entry knockout provided and (16th Edition) BS 7671:2001, and are an FDA adaptor and Profile 29 flat rated IPX5. The motor is totally duct. Alternatively 100mm diameter enclosed and fitted with self aligning circular duct can be used. A clip-off bearings and thermal overload front and removable fan blade make protection. The motor insulation is for easy cleaning. Select the right product for your application

LVDX200 LVDX200T LVCF20 LVCF20T Reference number 91453AW 91040AW 91041AW 91042AW Remote switch (not supplied) n n n Integral pullcord nn Integral adjustable run-on timer (30s to 20mins) nn Humidity sensor (50-90% RH) n n Quick visit (2 minutes) nn Speeds 2 2 5 5 Trickle ventilation facility n n Extract performance (FID, m3/h) boost 108 108 speed 3 102 102 speed 2 108 108 79 79 speed 1 45 45 50 50 trickle 36 36 Extract performance (FID, l/s) boost 30 30 speed 3 28 28 speed 2 30 30 22 22 speed 1 12.5 12.5 14 14 trickle 10 10 Sound pressure level (dB(A)@3m) boost 50 50 speed 3 48 48 speed 2 50 50 42 42 speed 1 30 30 32 32 trickle 26 26 Max. electrical power rating (W) 42 42 42 42 IP rating IPX5 IPX5 IPX5 IPX5 Weight (kg) 2.15 2.15 2.15 2.15 Guarantee (years, UK) 3 3 3 3

14 Models

Premier LVDX200 Premier LVCF20 Premier LVCF20T Ref. 91453AW Ref. 91041AW Ref. 91042AW • High performance centrifugal unit • High performance condensation control • High performance condensation control • Stylish 2 piece fascia with neon indicator centrifugal unit centrifugal unit with timer (30s-20mins) • Choice of 2 set speeds • Integral condensation controller • Integral condensation controller • Operated by remote switch eg. lighting circuit • Stylish 2 piece fascia • Stylish 2 piece fascia • User adjustable humidistat (50-90% RH) • User adjustable humidistat (50-90% RH) Premier LVDX200T • Room size selector matches extract • Room size selector matches extract Ref. 91040AW performance for improved efficiency performance for improved efficiency • High performance centrifugal unit with timer • Trickle ventilation facility • Operated by remote switch eg. lighting circuit n

• Stylish 2 piece fascia o • Automatic or pullcord manual override • Trickle ventilation facility i • Operated by remote switch eg. lighting circuit • Includes external wall grille • Automatic or pullcord manual override t a

• ‘QuickVisit’ delay feature prevents fan from l

• Neon indicator • Neon indicator i running should light be switched On/Off • Includes external wall grille t again within 2mins n • Built-in run-on period after light switched Off. Typical Specifications on page 160. e v User adjustable from 30s-20mins Wiring Diagrams on page 180.

• Neon indicator Remote Sensors on page 56. e g a t Performance l o

LVDX200 Range LVCF20 Range V w o L a r t x E y t e f a S | 0

Dimensions (mm) 2 F LVDX200 Range LVCF20 Range LV transformer C V L

100 100 100 & 0 0 2 X

Installation and Accessories D V L t l o V o L r e i

Wall Mounting Flush Wall Mounting Ceiling Mounting Flush Ceiling Surface Ceiling Window Mounting m with flat ducting Mounted Mounted e

Hole diameter: 117mm Hole diameter: 117mm or (w 203 x h 233mm flush mounted) Hole diameter: 120mm r P

Installation Accessories Installation Accessories r

Installation Accessories i a

Wall tube WD100 Ref. 89543AA Flat ducting XFP see Profile 29 Glass mounting kit GMK l Wall vent kit VK10 Ref. 89120AW Flexible ducting FD100 Ref. 89910AA Ref. 90546AA Condensation trap XCT100 Ref. 89749AA e Vent cowl VC10 Ref. 89531AW p

Flat duct adaptor FDA Ref. 90547AA X Ceiling mounting adaptor XCMK Ref. 90066AA 15 Xpelair Premier LVCF20T DC Centrifugal safety extra low voltage fan with UltraDC technologyNEW NEW

Key features The Range

Type: Selv UltraDC The new Xpelair Premier Selv with The unit can be surface or recess centrifugal wall fan UltraDC technology, safe, energy mounted at any angle. efficient and long lasting. with condensation For complete peace of mind Premier control and overrun The Premier is designed with installer LVCF20T DC is IPX5 Safety Extra Low timer. selectable settings to satisfy Part F1 Voltage rated for installation in splash installed performances for intermittent zone 1 and zones 2 / 3 of a bath or ventilation in bathrooms and sanitary shower. Application: Intermittent ventilation accommodation; continuous extract in in toilets & bathrooms. kitchens, utility rooms, bathrooms and Premier features UltraDC offering an Continuous extract in sanitary accommodation. All from one 80% reduction in energy use, a choice fan with whisper quiet operation. of installed performances and longer kitchens, utility rooms, life, typically up to five times longer bathrooms or toilets. Premier offers centrifugal performance than a conventional AC motor. For this with an UltraDC motor. This ensures a reason Xpelair offers a 5 year UK Control options: Pullcord override. constant pressure development and only guarantee. Quick visit 2min delay. lower energy use than many axial AC fans and requires no filter. Adjustable timer overrun. Versatile standard built-in options allow Adjustable humidistat. the installer to select any combination of advanced features: active response humidity control, adjustable overrun Legislation: Suitable for IEE Zone 1. timer, ‘Quick visit’ delayed start and Use conforms to pullcord BOOST override. Building Regulations Part F1 & Scottish Building Regulations.

Hole diameter: 117mm surface 232(w) x 280(h)mm. Recess mounting.

Select the right setting for your application

Premier LVCF20T DC

Reference number 92288AW Integral pullcord boost override Yes 15l/s Adjustable overrun timer Yes (30sec-20 minutes) Quick Visit delayed On Yes 2 minutes Active response humidistat Yes 70-90% RH. Factory set at 70% RH Selectable installed performances 6l/s 8l/s 13l/s 15l/s assumes installed with WL kit Sound pressure level (dB(A)@3m) 22.8 24.7 28.2 29.3 Electrical power rating 3.5W 3.9W 5.0W 5.1W max IP rating IPX5 Weight 4.25kg Transformer Located outside of spray area Zone 3 Guarantee 5 years 16 Models Dimensions (mm)

Premier LVCF20T DC • ‘Quick visit’ delay feature prevents the fan Ref. 92288AW from running should the light be switched On y and Off again within two minutes • UltraDC motor g o

• Auto run status light l • Selectable installed speeds to satisfy 100 Part F1 requirements ( table 1.1a) • Pullcord boost override with status light o n - Intermittent bathroom 15l/s h - Intermittent sanitary accommodation 8l/s • Surface or recess mounting c

- Continuous extract kitchen 13l/s • A separate SELV transformer is supplied e t - Continuous extract bathroom 8 l/s with the unit for installation outside of - Continuous extract sanitary Zones 1 & 2 C accommodation 6l/s

Transformer D

• Active response condensation control a r

humidistat factory set for UK ambient t l conditions. Installer adjustable from 70 - 90%RH U h

Typical Specifications on page 160. t • Built-in run-on period after the light has i been switched Off, user adjustable from Wiring Diagrams on page 180. w 30s -20min. Overrun timer is typically Remote Sensors on page 56.

connected to a lighting circuit n a f e g

Performance a t l o v w o l a r t x e y t e f a s l a g u f i r t n e C | Installation and Accessories C D T 0 2 F C V L Wall Mounting Ceiling Mounting Ducted Applications Ventilation Shaft Mounting r

Hole diameter: 115mm Hole diameter: 115mm e Ducting size: 100mm Ducting size: 100mm Hole diameter: 115mm i Ducting size: 100mm m Installation Accessories Installation Accessories e r Easy fit kit EFT Ref. 90427AA Flat ducting XFP see Profile 60 Wall Tube WD100 Ref. 89543AA Flexible ducting FD100 Ref. 89910AA P

Condensation trap XCT100 Ref. 89749AA r Vent cowl VC10 Ref. 89531AA i

Ceiling mounting kit XCMK Ref. 90066AA a l e p

17 X Xpelair Premier CF20/40T CV Centrifugal extract and condensation control fansNEW NEW

Key features The Range

Type: Constant Volume The Premier CF20/40T CV model constant irrespective of the installed UltraEC Centrifugal features UltraEC technology offering condition up to a system pressure of extract fan reduced energy use, a choice of 100Pa. The fan can be surface or installed performances and a longer flush mounted in walls and ceilings Application: Intermittent ventilation, life than a conventional AC motor. using the universal mounting accessories provided. Humidity controlled The fan is designed to comply with the intermittent ventilation, requirements of Part F1 to provide The fan is provided with a back Decentralised Intermittent Ventilation in Kitchens, draught shutter for intermittent ventilation Utility rooms, Bathrooms and Sanitary applications. It is not to be fitted for the Rooms, Humidity Controlled lower velocity continuous decentralised Control options: Installer selectable intermittent Ventilation + manual over- applications. Control options include humidistat, timer and ride in Kitchens and Bathrooms, integral Humidistat, pullcord over-ride, pullcord override Intermittent Ventilation in Internal rooms run on timer and 'quick visit' delay and Decentralised Continuous start facility. Xpelair offers a 5 year UK Legislation: Conforms to Building Ventilation in Kitchens, Utility Rooms, only guarantee. Bathrooms and Sanitary Rooms. Regulations Part F1 Performance is set at installation via a Hole diameter: 115mm series of internal dip switches. The Constant Volume nature of the fan means that performance remains

Select the right setting for your application At Zero Static Pressure*

Speed Settings Extract Performance Noise dB(A) @ 3m Power (W)

Intermittent Ventilation l/s m3/h Kitchen 60l/s 216m3/h via integral pullcord 55.8 31W Utility 30l/s 108m3/h via integral pullcord 39.9 8.4W Bathroom 15l/s 54m3/h via integral pullcord 22.7 4.9W Sanitary Room 6l/s 22m3/h via remote switch (not supplied) 20.8 4.2W Humidity Controlled intermittent Ventilation + manual over-ride Kitchen 60l/s 216m3/h Off. Humidity. pullcord 55.8 31W Bathroom 15l/s 108m3/h 216m3/h Off. Humidity. pullcord 22.7 4.9W Intermittent Ventilation - Internal Rooms Kitchen 60l/s 216m3/h + 15min over-run timer triggered via light switch 55.8 31W Utility 60l/s 216m3/h + 15min over-run timer triggered via light switch 55.8 31W Bathroom 15l/s 54m3/h + 15min over-run timer triggered via light switch 22.7 4.9W Sanitary Room 15l/s 54m3/h + 15min over-run timer triggered via light switch 22.7 4.9W Decentralised Continuous Ventilation Kitchen 13l/s 20.8 4.6W Utility 8l/s 21.4 4.4W Bathroom 8l/s 21.4 4.4W Sanitary Room 6l/s 20.8 4.2W *Measured with 300mm of ducting and wall grille fitted on the outlet side. Note: As this is a constant volume product, as the back pressure on the system increases so the motor increases speed to maintain airflow. This has the effect of increasing motor input power. Product is rated at 230V, 50/60Hz, single phase. 18 Models Dimensions (mm)

Premier CF20/40T CV • Built in Humidistat controlled intermittent Ref.92293AW ventilation option

• Constant Volume with speed • Built in timer controlled intermittent ventilation selectable at installation by means of dip option for internal rooms switches. • Run on period of 20 sec-20min • UltraEC longlife low energy motor (installer adjustable) after light has been switched Off. Factory set at 15 min in • External rotor motor with integral balanced compliance with Part F1 impellers, sealed for life maintenance free bearings and safety thermal cut • 'Quick visit' feature prevents the fan out protection coming on if the room is occupied for

less than two minutes s

• Fan maintains selected extract volume n

irrespective of system resistance up • Includes external wall grille and fan backdraft a to 100Pa shutter for intermittent applications f l

Typical Specifications on page 161. o r

Wiring Diagrams on page 181. t

Remote Sensors on page 56. n o c

Performance n o i t a s n e d n o c d n a t c a r t x e l a g u f i r t n e C | V C T 0

Installation and Accessories 4 / 0 2 F C r e i m Wall Mounting Ceiling Mounting Ducted Applications Ventilation Shaft Mounting e r Hole diameter: 117mm Hole diameter: 117mm Hole diameter: 117mm Ducting size: 100mm Ducting size: 100mm Ducting size: 100mm P r

Installation Accessories Installation Accessories i a

Easy fit kit EFT Ref. 90427AA Flat ducting XFP see Profile 60 l Wall Tube WD100 Ref. 89543AA Flexible ducting FD100 Ref. 89910AA e Condensation trap XCT100 Ref. 89749AA Vent cowl VC10 Ref. 89531AA p

Ceiling mounting kit XCMK Ref. 90066AA 19 X

Xpelair Profile 29 & Profile 25M Flat duct systems

Key features The Range

Type: Low profile flat plastic The ideal ducting solution for a variety Assembly is easy using push fit flat & metal ducting of domestic installations where ceiling channel connectors and the system is or wall space is limited. held to the wall or ceiling using quick- fit support clips. The ducting can be Application: Particularly suitable for In many refurbishment projects walls or terminated in a conventional wall grille use with Premier ceilings are battened to provide a narrow or a choice of horizontal or soldier space for services such as plumbing DX180, DX200/400 & course airbricks, and is then simply electrical wiring and ventilation. Where CF20/40 models. concealed behind plasterboard. space is limited Profile duct is ideal Size options: Plastic 234mm x 29mm above kitchen wall units, in cavity walls Some applications call for traditional and even under floors. galvanised sheet steel ducting. For (GSM) Metal these applications Profile 25M metal Xpelair Profile 29 is an easy to 230mm x25mm flat ducting can be used. Profile 25M assemble, push fit, modular ventilation measures 230 x 25mm and is also duct system designed for flush Installation: Simple push fit & easily available in an extensive range of mounted fan installation within a concealed interconnecting components. With a minimum gap of 50mm ceiling void. It is depth of only 25mm it is ideal for lightweight and easy to cut to length installation between the floor/ceiling using a cross-cut saw. Profile 29 slab and the plasterboard finish. It can systems are non reverberant and will be fixed to the ceiling/wall by suitable not deteriorate in applications where fixings through the continuous flange high humidity is present. on either side. All joints should be The system includes a full range of sealed with a sealing compound. vertical and horizontal bends including Profile 60 flat plastic duct system is special adaptors for connection to the also available for installations where a top and rear of Premier DX200 & CF20 particularly low profile duct is not centrifugal fans. The extensive range of required, or where longer duct runs accessories offers the flexibility to are required. achieve almost any ducting configuration in particularly tight spaces. Details shown on page 52-53.

Exploded diagram of flush mounted Premier DX200 installation

20 Profile 29 Flat Plastic Ducting - w234 x h29mm Profile 25M Flat Metal Ducting - w230x h25mm

Product Product Ref Description Dimensions Ref. No. Product Product Ref Description Dimensions Ref. No.

FMD Flat ducting 230 x 25 89758AA XFD Flat channel duct 1m 234 x 29 91104AA 2.4 metre length Flat channel duct 1.5m 234 x 29 91105AA Flat channel duct 2m 234 x 29 91106AA FMH90 Horizontal 90º bend 230 x 25 89759AA

XFC Flat channel connector 234 x 29 91107AA FMTB Transition/air brick 230 x 25 89760AA

XFH90 Horizontal 90º bend 234 x 29 91108AA FMP Plenum box 230 x 25 89761AA

XFH45 Horizontal 45º bend 234 x 29 91109AA FMV90 Vertical 90º bend 230 x 25 89762AA

XFV90 Vertical 90º bend 234 x 29 91110AA FMH45 Horizontal 45º bend 230 x 25 89763AA

XFV45 Vertical 45º bend 234 x 29 91111AA FMC Coupling (boxed in 6’s) 230 x 25 89764AA

XFEP Elbow bend/plenum 234 x 29 91112AA 100mm ID spigot (female)

XFRRA Round to rectangular adaptor 234 x 29 91113AA 100mm ID spigot (female) Typical installation of Premier XFS Universal support clip 91114AA DX200 with Profile 29 ducting s m e FDA Flat ducting adaptor kit 90547AA t s y s

XFLAA Long airbrick adaptor 234 x 65 91102AA t c u d

XFAF Airbrick fascia terracotta 205 x 62 91103AA t a

Airbrick fascia white 205 x 62 91126AA l

Airbrick fascia brown 205 x 62 91127AA F Airbrick fascia cotswold stone 205 x 62 91128AA |

XFAS Airbrick soldier course 91246AA M 5 2

XFWT 100mm telescopic wall tube 91247AA e l i f o

Typical Specifications on page 161. r P

Dimensions (mm) & 9

Profile 29 Profile 25M 2

Flat channel outer Flat channel outer dimensions e l

dimensions are w240 x h34 are w230 x h25mm and fit i f

mm and fit directly into directly into system parts o

system parts sockets to sockets to create ducting r

create ducting runs. Cross runs. Cross section: 5750mm2 P 2 section: 6786mm r Minimum space required for i

Minimum space required for installation: w235 x h30mm a l

installation: w240 x h38mm e p X 21 Xpelair DX100 & XX100 100mm Axial extract fans

DX100 XX100

Key features The Range

Application: Domestic bathrooms, A comprehensive range of stylish, XX100 models are supplied without a shower rooms and compact and easy to install single kit and are ideal for replacement toilets. All models come speed fans. Suitable for a wide range of applications or where a suitable outlet complete with wall and domestic applications including already exists. window fitting kit bathrooms, shower rooms and toilets, All models are IPX5 rated (except including zones 1 & 2. Also suitable for DX100PIR) and BEAB approved, Control options: Pullcord, timer, commercial applications such as hotel demonstrating accredited levels of humidistat and PIR bathrooms, office toilets and other safety. They are all suitable for 220- small rooms. 240V 50Hz mains operation, have Legislation: Conforms to Building DX100 models have a softly curved lubricated for life motors, Class B Regulations Part F1 flowline grille design which will blend insulation for operation in ambient into wall or ceiling décor, whilst the temperatures up to 40ºC and are fitted Hole diameter: 117mm (wall/ceiling) shallow depth of the outlet spigot with a thermal cut out. 125mm (window) ensures compact window installation. 110mm (shaft/ducting) All models come complete with a universal mounting kit (wall tube, gasket x2, outer grille, skirt moulding for window) suitable for wall, ceiling or window mounting (in single glazing up to 6mm) applications. The DX range includes an air operated backdraught shutter, outer grille and ducting. Control options include integral pullcord and timer; humidistat and PIR options offer automatic control. DX100 fan complete with Universal Mounting Kit Select the right product for your application

DX100 DX100PC DX100T DX100H DX100HP DX100PIR XX100 XX100P XX100T Reference number 90839AW 90840AW 90841AW 90842AW 90843AW 90844AW 90872AW 90873AW 90874AW Remote switch (supplied separately) nn nn Integral pullcord nnn Integral timer (adjustable from 2-20 mins) nnnn n Humidity sensor (50-90% RH) nn Passive infrared sensor n Maximum air flow (FID, m3/h) 76 76 76 76 76 76 76 76 76 Maximum air flow (FID, l/s) 21 21 21 21 21 21 21 21 21 Sound pressure level (dB(A)@3m) 35 35 35 35 35 35 41 41 41 Electrical power rating (W) 12 12 12 12 12 12 12 12 12 IP rating IPX5 IPX5 IPX5 IPX5 IPX5 IPX4 IPX5 IPX5 IPX5 Universal mounting kit nnn n n n Weight (kg) 1.2 1.2 1.2 1.2 1.2 1.2 0.8 0.8 0.8 Guarantee (years, UK) 3 3 3 3 3 3 3 33

22 Models Controllers

DX100 • Automatic On/Off operation by integral Remote Humidistat XRH Ref. 90839AW humidity sensor, adjustable from Ref. 21856AW • Single speed axial unit 50-90% RH • Stand alone humidistat switches fan On/Off • Operated by a remote switch or sensor • Pullcord On feature overrides the auto- when RH reaches pre-set levels. Complete (In a bathroom normally a separate pullcord humidity sensor function with pullcord override switch or the lighting circuit) • Includes universal mounting kit • Includes universal mounting kit • Colour: White Time Delay Unit DT20B • Colour: White DX100PIR Ref. 21850AW DX100PC Ref. 90844AW • User adjustable run on timer (2-20mins) Ref. 90840AW • Single speed axial unit with PIR detector • Single speed axial unit with pullcord • Automatic On/Off operation Passive Infrared Sensor XPIRA • Operated by integral pullcord • Integral passive infrared sensor Ref. 21871AA • Includes universal mounting kit • Includes universal mounting kit • Activates fan via body movement. Ideal for • Colour: White • Colour: White infrequently used public spaces. Built in timer to prevent nuisance tripping DX100T XX100 Ref. 90841AW Ref. 90872AW • Single speed axial unit with timer • Single speed axial unit Performance • Timer triggered by a remote switch - usually • Operated by remote switch DX100 / XX100 Range the lighting circuit • Colour: White • Adjustable timer (2-20mins) • Includes universal mounting kit XX100P • Colour: White Ref. 90873AW • Single speed axial unit with pullcord DX100H • Operated by integral On/Off pullcord Ref. 90842AW • Colour: White • Single speed axial unit with humidistat • Automatic On/Off operation by integral XX100T humidity sensor, adjustable from 50-90% Ref. 90874AW RH • Single speed axial unit with timer • Timer function adjustable (2-20mins) • Normally triggered by a remote • Includes universal mounting kit switch, for example the lighting circuit • Colour: White • Colour: White DX100HP Ref. 90843AW • Single speed axial unit with humidistat Typical Specifications on page 161. and pullcord Wiring Diagrams on page 181. • Timer function adjustable (2-20mins) Remote Sensors on page 56. s n a f

Dimensions (mm) t c a

DX100 Range Back draught shutter XX100 r t x e l a i x a m m 0

Installation and Accessories 0 1 | 0 0 1 X X & 0 Wall Mounting using Ceiling Mounting Wall Mounting using Ventilation Shaft Mounting Ducting Application 0 kit provided kit provided Hole diameter: 117mm Hole diameter: 110mm Hole diameter: 110mm 1

Hole diameter: 117mm Ducting size: 100mm Hole diameter: 125mm Ducting size: 100mm X

Ducting size: 100mm Max. glass thickness: 6mm D Installation Accessories Installation Accessories

Alternative Accessories Installation Accessories r Condensation trap XCT100 Condensation trap XCT100 i

Easy fit kit EFT Ref. 89749AA Double glazing kit DXDG Ref. 89749AA a l Ref. 90427AA Vent cowl VC10 Ref. 07439AA Vent cowl VC10 Ref. 89531AA e

Ref. 89531AA p

Air brick adaptor XAA X Ref. 89777AA 23 Xpelair LoVolt LV100 Safety Extra Low Voltage 100mm axial extract fans

Key features The Range

Application: Domestic bathrooms, Water, water everywhere and none in or ceiling décor, whilst the shallow shower rooms and toilets. the right place! depth of the outlet spigot ensures compact window installation. All models All models come complete Whether you are showering, or leaving come complete with a universal with wall and window the kids splashing in the bath, water mounting kit suitable for wall, ceiling or fitting kit gets everywhere. Xpelair LV100 fans window mounting (in single glazing up are 12V Safety Extra Low Voltage to 6mm) applications. Control options: Pullcord, timer, (SELV) units offering complete peace humidistat & PIR of mind. These fans are specifically The kit includes an air operated designed to be installed directly in or backdraught shutter and all models are Legislation: Conforms to Building over the splash area zone 1 in supplied with a 12V SELV transformer. Regulations Part F1 complete safety, with the SELV Control options include integral transformer sited out of reach of any pullcord and timer. Humidistat and PIR Hole diameter: 117mm (wall/ceiling) person using the bath or shower. options offer automatic control. 125mm (window) The front fascia with its softly curved The LV100 range conform to Building 110mm (shaft/ducting) flowline grille design will blend into wall Regulations mechanical ventilation for toilets and bathrooms. The Xpelair SELV system exceeds the IP requirements for zone1 and zone 2 as defined by IEE wiring Regulations (16th Edition) BS 7671:2001. All models are IPX5 rated and BEAB approved, demonstrating accredited levels of safety. They are all suitable for 220- 240V 50Hz mains operation, have lubricated for life motors, Class B insulation for operation in ambient temperatures up to 40ºC and are fitted DX100 fan complete with universal mounting kit Ideal for splash areas with a thermal cut out. Select the right product for your application

LV100 LV100PC LV100T LV100H LV100HP LV100PIR Reference number 90845AW 90846AW 90847AW 90848AW 90849AW 90867AW Remote switch (supplied separately) nn Integral pullcord nn Integral timer (adjustable from 2-20 mins) nn n n Integral humidity sensor (50-90% RH) nn Passive infrared sensor n Extract performance (FID, m3/h) 85 85 85 85 85 85 Extract performance (FID, l/s) 24 24 24 24 24 24 Sound pressure level (dB(A)@3m) 37 37 37 37 37 37 Electrical power rating (W) 13 13 13 13 13 13 IP rating IPX5 IPX5 IPX5 IPX5 IPX5 IPX5 Weight (kg) 2.2 2.2 2.2 2.2 2.2 2.2 Guarantee (years, UK) 3 3 3 3 3 3

24 Models Controllers

LV100 humidity sensor. Adjustable from 50-90% RH LoVolt Remote Humidistat LVH Ref. 90845AW • Adjustable timer function (2-20mins) Ref. 21863AW • Single speed 12V SELV axial unit and • Includes universal mounting kit • Stand alone humidistat switches fan On/Off remote SELV transformer • Colour: White when the relative humidity reaches pre-set • Operated by remote switch or sensor levels. This level is user adjustable to (in a bathroom normally a separate pullcord LV100HP suit each application or lighting circuit) Ref. 90849AW • Includes universal mounting kit • Single speed 12V SELV axial unit with • Colour: White humidistat, pullcord and remote SELV transformer LV100PC • Automatic On/Off operation by integral Performance Ref. 90846AW humidity sensor. Adjustable from 50-90% RH LV100 Range • Single speed 12V SELV axial unit with • Adjustable timer function (2-20mins) pullcord and remote SELV transformer • Pullcord On feature overrides the auto- • Operated by integral pullcord humidity sensor function • Includes universal mounting kit • Includes universal mounting kit • Colour: White • Colour: White s

LV100T LV100PIR n

Ref. 90847AW Ref. 90867AW a f • Single speed 12V SELV axial unit with timer • Single speed 12V SELV axial unit with PIR t

and remote SELV transformer detector and remote SELV transformer c

• Timer triggered by a remote switch, for • Automatic On/Off operation a r

example the lighting circuit. Timer variable • Integral passive infrared sensor t

from 2-20mins • Adjustable timer function (2-20mins) x

• Includes universal mounting kit • Includes universal mounting kit e • Colour: White • Colour: White l a i

LV100H x

Ref. 90848AW Typical Specifications on page 162. a • Single speed 12V SELV axial unit with Wiring Diagrams on page 181.

humidistat and remote SELV transformer Domestic Accessories on page 56. m

• Automatic On/Off operation by integral m 0

Dimensions (mm) 0 1

LV100 Range Back Draught Shutter LV100 Transformer e g a t l o V w o L a r t

Installation and Accessories x E y t e f a S | 0 0 1 Wall Mounting using Ceiling Mounting Window Mounting using Ventilation Shaft Mounting Ducting Application kit provided kit provided V Hole diameter: 117mm Hole diameter: 110mm Hole diameter: 110mm L

Hole diameter: 117mm Ducting size: 100mm Hole diameter: 125mm Ducting size: 100mm t Ducting size: 100mm Max. glass thickness: 6mm l

Installation Accessories Installation Accessories o Alternative Accessories Installation Accessories V Condensation trap XCT100 Condensation trap XCT100 Easy fit kit EFT Ref. 89749AA Double glazing kit DXDG Ref. 89749AA o Ref. 90427AA Vent cowl VC10 Ref. 07439AA L

Air brick adaptor XAA Ref. 89531AA r Ref. 89777AA i a l e p X 25 Xpelair Slimline SL100, SL150 & SG150HP Wafer thin axial fans NEW NEW

SL100SL150 SG150HP

Key features The Range

Application: Domestic bathrooms, Meet the new generation of Xpelair But the Slimline range doesn’t just shower rooms, toilets, Slimline SL100 and SL150 fans, with have a pretty face, installation is simple wall, ceiling and wall hugging wafer-thin too. All Slimline models have two window fitting. For wall designed for modern living. They are adjustable QuickClamp fixings which or duct mounting white in colour and are ideal for make traditional wall plug and screw domestic bathrooms, shower rooms, fixings a thing of the past (excluding Control options: Pullcord, timer & toilets and other small rooms. With an the SG150HP). humidistat internal projection of only 10mm, the The IPX4 rated units fully meet the 100mm Xpelair Slimline unit is one of requirements of the Building the lowest profile bathroom fans Legislation: Conforms to Building Regulations for bathrooms, toilets and available. For bigger bathrooms Regulations Part F1 kitchens and the IP requirements for Slimline is also available in a 150mm zone 1 and zone 2 as defined by the size offering performance and Spigot diameter: 100mm (SL100) IEE Wiring Regulations (16th Edition) style (SG150HP internal projection 150mm (SL150) BS7671:2001. All models are suitable of 58mm). for a supply voltage of 220-230V 50Hz For rooms with no opening windows and ambient temperatures up to 40ºC. Slimline SL100 is available with a Excludes the SG150HP built-in overrun timer. Humidistat models are available for shower rooms and heavily used bathroom applications. Ordering is straight- forward: simply select the size and control option required, then add the appropriate window or wall kit (SG150HP comes with a window kit).

Wafer thin grille Select the right product for your application

SL100 SL100P SL100T SL100HT SL150 SL150P SL150T SL150HT SL150HP SG150HP

Reference number 91225AW 91226AW 91227AW 91228AW 91229AW 91230AW 92361AW 91231AW 91496AW 92349AW Remote switch (supplied separately) n n n n n n n Integral pullcord n n n n Integral timer (adjustable up to 15 mins) n n n n n* n* Integral humidity sensor (45-99% RH) n n n** n** Extract performance (FID, m3/h) 67 67 67 67 218 218 218 218 218 218 Extract performance (FID, l/s) 18.5 18.5 18.5 18.5 60 60 60 60 60 60 Sound pressure level (dB(A)@3m) 39 39 39 39 43 43 43 43 43 43 Electrical power rating (W) 15 15 15 15 35 35 35 35 35 38 IP rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX2 Weight (kg) 0.6 0.6 0.6 0.6 0.9 0.9 0.9 0.9 0.9 1.5 Guarantee (years, UK) 2 2 2 2 2 22 2 2 2 * Adjustable upto 0-35 mins ** 50-80% RH

26 Models

SL100 • Integrated overrun timer eliminates • Built in backdraught shutter Ref. 91225AW nuisance tripping • Colour: White • Single speed axial fan • Timer variable from 45s-15mins • Operated by remote switch or sensor • Colour: White SL150HP (in a bathroom normally a separate pullcord Ref. 91496AW or lighting circuit) SL150 • Speed increases automatically as humidity Ref. 91229AW increases • Colour: White • Single speed axial fan • Integral On/Off pullcord gives full speed SL100P • Operated by a remote switch or sensor, manual override Ref. 91226AW usually a lighting circuit • Built in backdraught shutter • Single speed axial fan with pullcord • Built in backdraught shutter • Colour: White • Operated by integral On/Off pullcord switch • Colour: White • Colour: White SG150HP SL150P Ref. 92349AW SL100T Ref. 91230AW • Speed increases automatically as humidity Ref. 91227AW • Single speed axial fan with pullcord increases • Single speed axial fan with timer • Operated by integral On/Off pullcord switch • Integral On/Off pullcord gives full speed • Timer triggered by remote switch-usually the • Built in backdraught shutter manual override lighting circuit • Colour: White • Built in backdraught shutter • Timer variable from 3-15mins SL150HT (SL150T see page 39) • Colour: White • Colour: White Ref. 91231AW • Can be window mounted, and has a built in silent action electro-thermo shutter cassette, • Single speed axial fan with humidistat and s SL100HT and an external grille overrun timer n Ref. 91228AW • Built in adjustable humidistat a • Single speed axial fan with humidistat and f • Integrated overrun timer eliminates Typical Specifications on page 162. overrun timer l nuisance tripping Wiring Diagrams on page 181. • Built in adjustable humidistat a • Timer variable from 45s-15mins Domestic Accessories on page 59. i x

Performance Controllers a n Passive Infrared Sensor XPIRA i h

Ref. 21871AA t

• Activates fan via body movement r

• Ideal for infrequently used public spaces e f

• Built in timer to prevent nuisance tripping a W | P

Remote Time Controller DT20B H

Ref. 21850AW 0

• User adjustable run-on timer (2-20mins) 5 1 Dimensions (mm) G S 8 4 1 0 0 & 9 SL100 SL150 9 SG150HP 1 Range Range 1 0 5

15 115 190 1 Installation and Accessories L S , 0 0 1 L S e

Wall Mounting Ceiling Mounting Window Mounting Ducted Applications n i l Hole diameter: 117mm (SL100) Hole diameter: 100mm (SL100) Hole diameter: 100mm (SL100) Hole diameter: 117mm (SL100) m

157mm (SL150) 157mm (SL150) 150mm (SL150) 157mm (SL150) i

Duct diameter: 100mm (SL100) l

150mm (SL150) S

Installation Accessories Installation Accessories Installation Accessories Installation Accessories r i a SL100 wall kit SLWK Flexible ducting FD100 SL100 window kit Flexible ducting FD100 l

Ref. 91232AW Ref. 89910AA Ref. 91234AW Ref. 89910AA e

SL150 wall kit SLWK Flexible ducting FD150 SL150 window kit* Flexible ducting FD150 p Ref. 91233AW Ref. 89671AA Ref. 91235AW Ref. 89671AA Condensation trap XCT100 X Ref. 89749AA * Backdraught shutter must be 27 removed

Xpelair CentrX Centrifugal panel fans

CT100 CT100+

Key features The Range

Application: Domestic bathrooms, CentrX is a range of two sizes of The slim stylish grille is easily shower rooms, toilets pressure developing centrifugal panel recognisable as Xpelair, with a and utility rooms for fans for ducted or through the wall bellmouth entry and finger guard wall or duct mounting applications. They are the ideal through which air is drawn directly into solution for ducted applications where the eye of the high performance Control options: Pullcord, timer & extra pressure development is centrifugal fan. The spigot outlet on humidistat required, including toilets, bathrooms, both sizes of unit is only 100mm shower rooms and utility rooms. reducing space requirements for flexible Legislation: Conforms to Building They are recommended in place of an ducting or Profile 60 rigid flat ductwork, Regulations Part F1 axial fan in exposed coastal situations all models come with built in or exposed high rise applications. backdraught shutter. They are also suitable for commercial Hole diameter: 150mm (CT100) For simplified installation models are applications for the ventilation of small 100mm (CT100+) available with a built-in overrun timer internal rooms. and humidistat. They can be installed at any angle. All have an 'On' indicator light and a maintenance free motor with sealed for life bearings and safety thermal overload protection.

Profile 60 duct work shown on page 52-53.

Slim stylish grille Select the right product for your application

CT100 CT100T CT100HT CT100+ CT100+P CT100+HT Reference number 91236AW 91237AW 91238AW 91239AW 91240AW 91241AW Remote switch (supplied separately) nn Integral pullcord n Integral timer (adjustable) nn n Integral humidity sensor nn Extract performance (FID, m3/h) 62 62 62 169 169 169 Extract performance (FID, l/s) 17 17 17 47 47 47 Sound pressure level (dB(A)@3m) 49 49 49 52 52 52 Electrical power rating (W) 25 25 25 45 45 45 IP rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 Weight (kg) 0.98 0.98 0.98 1.64 1.64 1.64 Guarantee (years, UK) 2 2 2 2 2 2

28 Models

CT100 CT100HT CT100+P Ref. 91236AW Ref. 91238AW Ref. 91240AW • Centrifugal panel fan • Centrifugal panel fan with humidistat and timer • Integral pullcord operation • Can be installed at any angle • Auto humidity control switches the fan on • With bellmouth and fingerguard • Operated by remote switch or sensor. with a rise in humidity above the preset level. • 100mm duct spigot In a bathroom usually a pullcord or wired to • Overrun timer (adjustable from 45s-15min) • Maintenance free motor with sealed the lighting circuit ensures the absence of nuisance tripping for life bearings and safety thermal • On indicator light • Can be installed at any angle overload protection • Slim fascia with bellmouth and fingerguard • On indicator light • Colour: White • 100mm duct spigot • Slim fascia with bellmouth and fingerguard • Maintenance free motor with sealed for life • 100mm duct spigot CT100+HT bearings and safety thermal • Maintenance free motor with sealed Ref. 91241AW overload protection for life bearings and safety thermal • With integral humidistat • Colour: White overload protection • Auto humidity control switches the fan • Colour: White on with a rise in humidity above the CT100T preset level. Ref. 91237AW CT100+ • Overrun timer (adjustable from 45s-15min) • Centrifugal panel fan with timer Ref. 91239AW prevents nuisance tripping • Connected to the room wiring circuit. • High output centrifugal panel fan • Can be installed at any angle • Provides a preset timed overrun (3-15mins) • For larger bathrooms and utility rooms • With bellmouth and fingerguard after the light has been switched off • Can be installed at any angle • 100mm duct spigot • Can be installed at any angle. • Operated by proprietary remote switch • Maintenance free motor with sealed • On indicator light. or sensor for life bearings and safety thermal • Slim fascia with bellmouth and fingerguard • With bellmouth and fingerguard overload protection • 100mm duct spigot • 100mm duct spigot • Colour: White • Maintenance free motor with sealed for life • Maintenance free motor with sealed bearings and safety thermal for life bearings and safety thermal Typical Specifications on page 162. overload protection overload protection Wiring Diagrams on page 181. • Colour: White • Colour: White Remote Sensor on page 56.

Performance Controllers

Remote Humidistat XRH Ref. 21856AW • Stand alone humidistat switches fan On/Off when RH reaches pre-set levels. Complete with pullcord override switch Remote Time Controller DT20B Ref. 21850AW • User adjustable run on timer (2-20mins) Passive Infrared Sensor XPIRA Ref. 21871AA • Activates fan via body movement. Ideal for infrequently used public spaces. Built in timer to prevent nuisance tripping s n a f l

Dimensions (mm) e CentrX 100 Range CentrX 100+ Range n a p l a g u f i r t n e

Installation and Accessories C

Installation Accessories |

Wall Mounting Wall tube WD100 X Ref. 89543AA r t Telescopic wall vent kit VK10 Ref. 89120AW n e Ceiling Mounting C Wall Mounting Ceiling mounting Flexible ducting FD100 Ref. 89663AA r

with ducting i Ceiling mounting adaptor Ref. 90066AA a Hole diameter: CT100 150mm Hole diameter: CT100 150mm l CT100+ 100mm Condensation trap XCT100

CT100+ 100mm e Ducting size: 100mm Ducting size: 100mm Ref. 89749AA Weather cowl VC10 p

Ref. 89531AA 29 X Xpelair XIL & XXS Inline shower fan systems Axial extract fans for shower cubicle applications

Key features The Range

Type: Inline single speed Step out of the shower cubicle. Is the • inline fan axial extract fan mirror ‘steamed over’?... • 3m of flexible duct systems There is another way. • Four worm drive clips • inline backdraught shutter Remove the cause of condensation at Application: Domestic bathrooms (XIL100 only) source with an Xpelair inline shower and shower rooms • Internal ceiling grille with sleek fan system. styling in white Control options: Standard or timer With a neat grille installed directly over • Outside soffit/wall grille the shower, humid or moist air will be XXS100 fans are available on their own. Legislation: Conforms to Building ducted away by a fan above the ceiling Regulations Part F1 and onwards to a grille installed All electronics circuits and wiring outside, typically in the soffit. terminals are fully protected. Motors are Class B lubricated for life, fitted Hole diameter: 117mm (XIL100/XXS100) Will I be standing in a draught? No, air with safety thermal overload protection 140mm (XIL125) will not be pulled into a normal cubicle, and suitable for ambient temperatures 165mm (XIL150) only flow over it. up to 40ºC. XIL fans are available in sizes of 100, Xpelair XIL systems conform to Building 125 & 150mm and are only available Regulations mechanical ventilation for as fan systems. The systems contain toilets shower rooms and bathrooms. all the components necessary for a normal installation, comprising:

Select the right product for your application

Shower Fan Systems Fan Only

XIL100 XIL100T XIL125 XIL125T XIL150 XIL150T XXS100 XXS100T Reference number 90329AW 90330AW 91242AW 91243AW 91244AW 91245AW 90331AW 90332AW Remote switch (not included) nnnn n n n n Fan only nn Fan system (installation pack) nnnn n n Integral timer (adjustable) nn n n Extract performance (m3/h*) 54 54 63 63 133 133 95 FID 95 FID Extract performance (l/s*) 15 15 18 18 37 37 26 FID 26 FID Sound pressure level (dB(A)@3m) 30 30 43 43 45 45 33 33 Electrical power rating (W) 29 29 20 20 25 25 29 29 Duct diameter (mm) 100 100 125 125 150 150 100 100 Hole diameter (mm) 115 115 140 140 165 165 115 115 IP rating IPX2 IPX2 IPX2 IPX2 IPX2 IPX2 IPX2 IPX2 Weight (kg) 0.9 0.9 1.83 1.83 2.1 2.1 0.8 0.8 Guarantee (years, UK) 3 3 2 2 2 2 2 2 *XXS fan only performance measured FID, XIL fan systems measured in typical installation (comprising 90o bend on the inlet & outlet plus 3m of duct).

30 Models s n o i XIL100 switch or wired to the lighting circuit) XIL150T t Ref. 90329AW Can also be wired to a water flow switch Ref. 91245AW a c i

• Single speed inline showerfan system. fitted in the pipework to the shower • Single speed inline showerfan system l • Operated by remote switch (in a control to switch On/Off when the • Built-in overrun timer (adjustable at p bathroom whether by remote pullcord shower is in use installation from 3-15mins) switch or wired to the lighting circuit) • Operated by remote switch (in a p • Can also be wired to a water flow switch XIL125T bathroom wired to the lighting circuit) a

fitted in the pipework to the shower Ref. 91243AW • Can also be wired to a water flow e l control to switch On/Off when the • Single speed inline showerfan system switch, fitted in the pipework to the c shower is in use • Built-in overrun timer (adjustable at shower control, to switch On/Off i

installation from 3-15mins) when shower is in use b

XIL100T • Operated by remote switch (in a u

Ref. 90330AW bathroom wired to the lighting circuit) XXS100 c

• Single speed inline showerfan system • Can also be wired to a water flow Ref. 90331AW r

• Built-in overrun timer (adjustable at switch, fitted in the pipework to the • Single speed inline fan e installation from 2-20mins) shower control, to switch On/Off • Operated by remote switch or sensor • Operated by remote switch or sensor when shower is in use w (in a bathroom wired to the lighting circuit) XXS100T o • Can also be wired to a water flow XIL150 Ref. 90332AW h switch, fitted in the pipework to the Ref. 91244AW • Single speed inline fan s shower control, to switch On/Off • Single speed inline showerfan system • Integral timer operated by remote switch r

• Operated by remote switch (in a (adjustable from 2-20mins) o when the shower is in use f bathroom either by a remote pullcord

XIL125 switch or wired to the lighting circuit) s Typical Specifications on page 163. Ref. 91242AW Can also be wired to a water flow switch n

• Single speed inline showerfan system fitted in the pipework to the shower Wiring Diagrams on page 182. a • Operated by remote switch or sensor control to switch On/Off when the Remote Sensors on page 56. f

(in a bathroom either by a remote pullcord shower is in use a r t x

Performance e l

XXS100 fan only XIL125/150 a i x A | s m e t s y s n a f r

Dimensions (mm) e

XIL range w Dimensions (mm) Model ØA B C o XIL100/T 100 108 109 h XIL125/T 118 118 96 s

XIL150/T 148 177 108 e

XXS100/T 100 108 109 n i l

Installation and Accessories n I S X X In-Line Internal Duct External Grille Grille

Fan &

In-Line Back Flexible L Draught Shutter Ducting I X

Wall Mounting Loft Mounting r i a l Hole diameter: 117/140/165mm* Hole diameter: 117/140/165mm* e Ducting size: 100/125/150mm* Ducting size: 100/125/150mm* p

*refer to table opposite *refer to table opposite X 31 Xpelair BriteX LoVolt & BriteX Turbo Shower fan and light systems

Key features The Range

Type: Inline single speed Brighten up your showering BriteX LoVolt is suitable for shorter axial / mixed flow experience. duct runs (3m duct supplied) in shower extract fan systems cubicles, bathrooms and toilets. For Shut the door on your shower and you larger shower rooms and longer ducts are probably standing in the darkest Application: Domestic toilets, choose BriteX Turbo which comes part of your bathroom. Xpelair BriteX bathrooms & complete with 6 meters of flexible range is designed to extract shower rooms ducting. For bathrooms without condensation laden air directly from windows versions with an adjustable above the shower whilst bathing the timer overrun are available, adjustable Control options: Standard or timer cubicle in warm light. from 1-20 minutes. The fan is typically Legislation: Conforms to Building Xpelair BriteX kits include everything connected to the bathroom lighting, Regulations Part F1 needed for a standard installation and it continues to run after the light including a stylish ceiling inlet has been switched off. complete with bezel and 12V 35W Hole diameter: 102mm The motor housing is made from ABS sealed dichroic lamp, an inline extract and has a detachable mounting foot. fan, 12V Safety Extra Low Voltage All BriteX systems can be installed in (SELV) transformer, flexible ducting, zone 1 in accordance with IEE duct ties and a soffit/wall grille. The kits Regulations 16th Edition. All versions are available in a choice of white or are IPX4 rated and suitable for use with chrome bezel. a supply voltage of 220-240V 50Hz. The fan motor is sealed for life maintenance free and is fitted with safety thermal overload protection. Select the right product for your application

Axial Mixed flow BX100W BX100WT BX100C BX100CT BX100+W BX100+WT BX100+C BX100+CT

Reference number 92276AW 92277AW 92278AW 92279AW 91248AW 91250AW 91249AW 91251AW Performance standard standard standard standard turbo turbo turbo turbo Remote switch (supplied separately) n n nn n nnn Lamp (12V 35W) LoVolt LoVolt LoVolt LoVolt LoVolt LoVolt LoVolt LoVolt Integral timer (adjustable from 1-20 mins) n n nn Extract performance (m3/h) 58 58 58 58 74 74 74 74 Extract Performance (l/s) 16 16 16 16 21 21 21 21 Duct length (supplied) 3m 3m 3m 3m 6m 6m 6m 6m Sound pressure level (dB(A)@3m) 36 36 36 36 55 55 55 55 Fan electrical power rating (W) 30 30 30 30 25 25 25 25 Hole diameter (mm) 102 102 102 102 102 102 102 102 IP rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 Colour white white chrome chrome white white chrome chrome Weight (kg) 0.5 0.5 0.5 0.5 2.1 2.1 2.1 2.1 Guarantee (years, UK) 333 3 2 2 2 2

32 Models

BriteX LoVolt • Suitable for shower cubicles, bathrooms BriteX Turbo T BX100W white bezel and toilets BX100+WT white bezel Ref. 92276AW • Stylish SELV rated air inlet with 50W Ref. 91250AW BX100C chrome bezel sealed dichroic lamp BX100+CT chrome bezel Ref. 92278AW • SELV transformer Ref. 91251AW • Suitable for shower cubicles, bathrooms • IPX4 rated double insulated fan. ABS • Fan fitted with overrun timer adjustable and toilets housing with detachable mounting foot from 3-15mins • 3m of flexible ducting • Sealed for life maintenance free motor • 6m of flexible ducting • Stylish SELV rated air inlet with 35W • Safety thermal overload protection • Fan typically connected to the bathroom sealed dichroic lamp • Duct ties lighting. Fan continues to run after the • SELV transformer • Soffit / wall grille colour brown light has been switched Off • IPX4 rated double insulated fan • Stylish SELV rated air inlet with 35W • ABS housing with detachable mounting foot BriteX Turbo sealed dichroic lamp • Sealed for life maintenance free motor BX100+W white bezel • SELV transformer • Safety thermal overload protection Ref. 91248AW • IPX4 rated double insulated mixed flow • Duct ties BX100+C chrome bezel inline fan. • Soffit/wall grille colour brown Ref. 91249AW • ABS housing with detachable mounting foot • Suitable for longer duct runs and larger • Sealed for life maintenance free motor BriteX LoVolt T bathrooms

• Safety thermal overload protection s BX100WT white bezel • 6m of flexible ducting • Duct ties Ref. 92277AW • Stylish SELV rated air inlet with 35W • Soffit / wall grille colour brown m

BX100CT chrome bezel sealed dichroic lamp e Ref. 92279AW • SELV transformer t s

• 3m of flexible ducting • IPX4 rated double insulated mixed flow inline y

• Fan fitted with overrun timer adjustable fan. ABS housing with detachable s

from 1-20mins mounting foot Typical Specifications on page 163. t • Fan is typically connected to the bathroom • Sealed for life maintenance free motor Wiring Diagrams on page 182. h

lighting. Fan continues to run after the light • Safety thermal overload protection g i has been switched off • Duct ties l

• Soffit/wall grille colour brown d

Performance n a

Britex LoVolt BX100 BritexTurbo SELV Ceiling Bezel n a f r e w o h S | o b r u T X e t

Dimensions (mm) i r BriteX LoVolt Range (axial) BriteX Turbo Range (mixed flow) B & t l o V o L Installation X

BriteX units can be installed with the inlet e located in Zone 1 of a bath or shower in t accordance with IEE regulations. The inlet i r bezel/light assembly fits flush to the ceiling. The fan is installed at the highest point in the B

duct run using the bracket provided to avoid a r possible build up of condensation in the duct. i

It is good practice to cut off any surplus duct. a l Extended duct and radiused bends improve Britex LoVolt Installation Britex Turbo Installation performance. The grille provided can be e installed in the soffit of the roof or in a gable p

end wall. Hole diameter: 102mm Hole diameter: 102mm X Ducting size: 100mm Ducting size: 100mm 33 Xpelair XIM Domestic inline mixed flow extract fans

Key features The Range

Type: Inline one or two Traditionally centrifugal ducted systems All models come complete with a speed mixed flow have been bulky and noisy. Well not any convenient mounting cradle which extract fans more. The new low profile Xpelair XIM makes installation or subsequent units provide plenty of useable power inspection simple. The terminal box is Application: Domestic bathrooms, for domestic ducted applications and easily accessible simplifying the electrical utility rooms, save on space too. The seven models connection. XIM units are either IPX2 or shower rooms in the range are ideal for ducted IPX4. Those rated IPX4 can be used in and kitchens applications where space is limited, wet room ducted applications. Their such as in bathrooms, shower rooms, plastic construction will not deteriorate in Control options: Standard or timer kitchens and other internal rooms high humidity conditions. They are without opening windows. double insulated and suitable for operation on a supply voltage 220 - 240V Legislation: Conforms to Building Available in four sizes, the new Xpelair 50Hz. All motors are maintenance free Regulations Part F1 XIM range of plastic mixed flow units with greased for life bearings, and have offers duties for a wide range of safety overload protection. ducted applications. They are dimensionally smaller than centrifugal units and with lower sound levels these units can often eliminate the need for a silencer. The two T models have a timer overrun adjustable from 3 to 15 minutes. Larger units have two speeds.

Select the right product for your application

XIM100 XIM100T XIM100+ XIM100+T XIM125 XIM150 XIM150T XIM200

Reference number 91252AW 91253AW 91254AW 91473AW 91255AW 91256AW 91257AW 91258AW Speeds 1 1 2 2 2 2 2 Remote switch (supplied separately) nn nn Integral timer (adjustable from 3-15 mins) nn Max. extract performance (FID m3/h) 77 77 251 265 476 476 845 Min. extract performance (FID m3/h) 190 198 358 358 599 Max. extract performance (FID l/s) 21 21 70 74 132 132 235 Min. extract performance (FID l/s) 53 55 99 99 166 Max. sound pressure level (dB(A)@3m) 14 14 22 25 39 39 39 Max. electrical power rating (W) 25 25 25 25 80 80 75 Duct size (mm) 100 100 100 125 150 150 200 IP rating IPX2 IPX2 IPX4 IPX4 IPX4 IPX4 IPX4 Weight (kg) 1.2 1.2 2.1 2.1 3.2 3.2 4.5 Guarantee (years, UK) 2 2 2 22 22

34 Models

XIM100 XIM100+ XIM150T Ref. 91252AW Ref. 91254AW Ref. 91257AW • Single speed inline fan • High performance 2 speed inline fan • Adjustable overrun timer from 3-15mins • Mixed flow impeller/guide vanes • Mixed flow impeller/guide vanes • 2 speed inline fan • Integral mounting cradle • Integral mounting cradle • Timer located in the terminal box • Rated as IPX2 • Rated as IPX4 • Timer triggered by lighting circuit • Mixed flow impeller/guide vanes XIM100T XIM125 • Integral mounting cradle Ref. 91253AW Ref. 91255AW • Rated as IPX4 • Single speed inline fan with adjustable • 2 speed inline fan overrun timer from 3-15mins • Mixed flow impeller/guide vanes XIM200 • Timer located in the terminal box • Integral mounting cradle Ref. 91258AW • Triggered by lighting circuit • Rated as IPX4 • 2 speed inline fan • Mixed flow impeller/ guide vanes • Mixed flow impeller/guide vanes • Integral mounting cradle XIM150 • Integral mounting cradle • Rated as IPX2 Ref. 91256AW • Rated as IPX4 • 2 speed inline fan • Mixed flow impeller/guide vanes • Plastic construction • Integral mounting cradle • Rated as IPX4

Performance Controllers

Change Over Switch COS Ref. 90108AW • Provides High-Low speed operation • Surface or recess mounting • 85 x 85mm s n a f t c Typical Specifications on page 163. a r

Wiring Diagrams on page 182. t

Remote Sensor on page 56. x e w

Dimensions (mm) o l f

XIM100/100+/125 XIM150/200 d

Dimensions (mm) e x

Model ØA B C D E F G i XIM100 98 177 238 99.5 89.2 100 20 m XIM100+ 98 217 262.4 100 100 168.3 21.3 e XIM125 122 217 262.4 100 100 168.3 21.3 n i XIM150 147 244 293.4 130 115 192.3 21.3 l n XIM200 197 278.5 363.6 142 140 230.2 51.5 i c i t

Installation and Accessories s e

Installation Accessories m o Wall Mounting D Flexible Ducting Xflex FD100 (3m) Ref. 89663AA Flexible Ducting Xflex FD125 (3m) Ref. 89664AA | Flexible Ducting Xflex FD150 (3m) Ref. 89665AA Flexible Ducting Xflex FD200 (3m) Ref. 89666AA Wall grille CFWG100 Ref. 89742AW M

Wall grille CFWG150 Ref. 89857AW I X

Xflex FD also available in longer length (see page 57) r XIM Wall installation Wall grille CFWG also available in grey i a l e p X 35

Kitchens and Utility Rooms

Ummm something smells Kitchens 60l/s (30l/s with a cooker hood) kitchen canopies, it should be located as and Utility rooms 30l/s. If the room does high as possible and provide a flow nice… not have an opening window then a fan across the room with air replacement The kitchen is often the focal point of the with a built in timer should be selected. usually coming from the doorway. This will continue to run for at least 15 home. It’s the place where we cook, Axial fans are suitable for through the wall minutes after the room has been vacated. wash up, eat and often entertain. It’s also or window fitting in most homes. For high- a source of heat, steam, and odours. Older properties present a different rise and exposed (e.g. coastal) locations, Cooking smells can wet your appetite but challenge. With generally larger rooms, centrifugal fans will cope better with gusty unchecked they drift and linger higher ceilings but poorer insulation, the conditions. Centrifugal and mixed flow throughout the house. Condensation can effects of condensation are often more units have a better pressure characteristic, damage furnishings and too much heat obvious. Here, a better method of which makes them more suitable where a can be a real problem in modern well- selecting a fan is based on room volume ducted solution is required. insulated dwellings. multiplied by air change. If there is a fuel burning appliance in the Properly ventilated, the kitchen can • Domestic kitchens 15-20 ach room, ensure that there is adequate air remain a fresh environment in which to replacement for both the fuel burning • Utility rooms 15-20 ach work and live. appliance and the fan. For kitchen canopies a speed selectable Utility rooms are often a mix of heat from In a kitchen, the right position will usually model with a high speed of over 450m3/h laundry equipment and VOC’s from be an external wall or a window, but keep is often necessary to capture the heat cleaning materials. They are subject to a away from direct heat sources over 40ºC, and steam from a hob with four pans. For variety of uses from clothes drying to such as an eye level grill. washing the dog! Ventilation effectively island installations this extract figure extracts this water vapour and odours. needs to be doubled. And don’t forget the fan needs to be accessible for regular cleaning. Ventilation, The extract point should always be For installations that fall within the scope working effectively, will pick airborne positioned to capture water vapour and of Building Regulations the unit particles, which would otherwise deposit to odours at source. With the exception of ventilation extract requirements are your décor.

36 Kitchens

NEW NEW NEW NEW NEW NEW

SL150/ GX6/ DX400/ CF20/40T SG150HPGX6 GXC6 GX6 EC2 GXC9 CF40 (UltraCV) Canopies Profile 60 CX10 CMF

Page Number 38 40 42 40 44 46 48-51 52 54 54 Fan Type Axial Axial Axial Axial Centrifugal Centrifugal Centrifugal Flat ducting Axial Centrifugal Positioning Wall Window Window Window Wall Wall Wall n/a Celing Ceiling / Wall / Wall / Wall Max extract rate 218 266 284 549 245-250 216 850 n/a 329 286 (m3/h) Duct dia (mm) 150 n/a n/a n/a 100 100 125 w204 x h60 200 102/150 Carbonlite nn

For Domestic Sensors, Switches & Accessories see pages 56 - 59 s n e h c t i

www.xpelair.co.uk 37 K

Xpelair Slimline SL150 & SG150HP Wafer thin axial fans NEW NEW

SL150 SG150HP

Key features The Range

Type: Axial extract fan with Meet the new generation of Xpelair The IPX4 rated units fully meet the wafer thin grille Slimline SL150 fans, with wall hugging requirements of the Building wafer-thin grilles designed for modern Regulations for bathrooms, toilets and Application: Kitchens and utility living. They are white in colour and are kitchens and the IP requirements for rooms ideal for utility rooms and other small zone 1 and zone 2 as defined by the rooms. With an internal projection of IEE Wiring Regulations (16th Edition) Control options: Pullcord, timer & only 15mm (SG150HP 58mm), the BS7671:2001. All models are suitable humidistat 150mm Xpelair Slimline unit is one of for a supply voltage of 220-230V 50Hz the lowest profile fans available. and ambient temperatures up to 40ºC.

Legislation: Conforms to Building Humidistat models are available for Regulations Part F1 shower rooms and heavily used bathroom applications. Ordering is Hole diameter: 150mm straight-forward: simply select the size and control option required, then add the appropriate window or wall kit (SG150HP comes with a window kit).

Excludes the SG150HP But the Slimline range doesn’t just have a pretty face, installation is simple too. All Slimline models have two adjustable QuickClamp fixings which make traditional wall plug and screw fixings a thing of the past (excluding the SG150HP).

Wafer thin grille SG150HP with silent action electrothermo shutter cassette and external grille Select the right product for your application

SL150 SL150P SL150T SL150HT SL150HP SG150HP

Reference number 91229AW 91230AW 92361AW 91231AW 91496AW 92349AW Remote switch (supplied separately) nnnn Integral pullcord nnn Integral timer (adjustable up to 15 mins) nn n* n* Integral humidity sensor (45-99% RH) nn** n** Extract performance (FID, m3/h) 218 218 218 218 218 218 Extract performance (FID, l/s) 60 60 60 60 60 60 Sound pressure level (dB(A)@3m) 43 43 43 43 43 43 Electrical power rating (W) 35 35 35 35 35 38 IP rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX2 Weight (kg) 0.9 0.9 0.9 0.9 0.9 1.5 Guarantee (years, UK) 2 2 2 2 2 2 * Adjustable upto 0-35 mins ** 50-80% RH

38 Models Controllers

SL150 • Integrated overrun timer eliminates Passive Infrared Sensor XPIRA Ref. 91229AW nuisance tripping Ref. 21871AA • Single speed axial fan • Timer variable from 3-15mins • Activates fan via body movement • Operated by a remote switch or sensor, • Built in backdraught shutter • Ideal for infrequently used public spaces usually a lighting circuit • Colour: White • Built in backdraught shutter • Built in timer to prevent nuisance tripping • Colour: White SL150HP Ref. 91496AW SL150P • Speed increases automatically as humidity Ref. 91230AW increases • Single speed axial fan with pullcord • Integral On/Off pullcord gives full speed • Operated by integral On/Off pullcord switch override • Built in backdraught shutter • Built in backdraught shutter • Colour: White • Colour: White

SL150T SG150HP Remote Time Controller DT20B Ref. 92361AW Ref. 92349AW Ref. 21850AW • Single speed axial fan with timer • Speed increases automatically as humidity • Timer triggered by remote switch-usually the increases • User adjustable run-on timer (2-20mins) lighting circuit • Integral On/Off pullcord gives full speed • Timer variable from 3-15mins manual override • Colour: White • Built in backdraught shutter Typical Specifications on page 164. • Colour: White Wiring Diagrams on page 182. SL150HT • Can be window mounted, and has a built in Remote Sensor on page 56. Ref. 91231AW silent action electro-thermo shutter cassette, • Single speed axial fan with humidistat and and an external grille overrun timer • Built in adjustable humidistat

Performance Dimensions (mm) s n

SL150 Range a f l a i x a n i h t r e f a SG150HP W | P H 0 5

Installation and Accessories 1 G S & 0 5 1 L

Wall Mounting Ceiling Mounting Window Mounting Ducted Applications S e Hole diameter: 157mm (SL150) Hole diameter: 157mm (SL150) Hole diameter: 150mm (SL150) Hole diameter: 157mm (SL150) n i

Duct diameter: 150mm (SL150) l m

Installation Accessories Installation Accessories Installation Accessories Installation Accessories i l S SL150 wall kit SLWK Flexible ducting FD150 SL150 window kit* Flexible ducting FD150 Ref. 91233AW Ref. 91235AW Ref. 89671AA r Ref. 89671AA i

* Backdraught shutter must be a removed l e p X 39 Xpelair GX6, GXC6 & GXC9 Kitchen axial fans

Key features The Range

Application: Domestic kitchens & For over forty years the Xpelair GX GXC models have an integral pullcord utility rooms for series has remained the specifiers’ actuator. Timer and humidistat versions wall or window mount classic solution to domestic ventilation are also available along with multi-speed applications. Today’s 5th generation of models. GXC6SC is also suitable for Control options: Pullcord GX units remains in tune with the times. professional speed adjustment where Timer They retain their hallmark rugged there is a fuel burning appliance in the Humidistat reliability and styling, and the range has room. A trickle ventilation facility is been expanded to include innovations available for background ventilation Legislation: Conforms to Building for a range of specialist tasks. when not in use. Now supplied with longer ladder strips. Regulations Part F1 Xpelair GX and GXC6 fans conform to Xpelair GX models are purpose Building Regulations mechanical Hole diameter: 203mm (GX6/C6 wall) designed for use in domestic kitchens, ventilation for kitchens. They are 184mm (GX6/C6 window) utility rooms, large bathrooms and designed for easy cleaning and 266mm (GXC9 wall) commercial applications such as small maintenance, are BEAB approved and 257mm (GXC9 window) offices. They are highly efficient axial are rated as Class 1 earthed appliance. fans suitable for direct ventilation to the For larger kitchens, especially in older outside. Window, wall or panel properties, a larger volume of air flow mounting options are available using may be appropriate in order to achieve the universal mounting kit provided. the recommended air change rates. All have a stylish white housing with For these applications the GXC9 may integrated safety finger guard and be more appropriate. Refer to the silent shutter operation using an commercial ventilation section for electro-thermal actuator (except GXC6 more details on larger wall and New longer ladder strips where it is pullcord operated). window models. Select the right product for your application

GX6 GX6T GX6HT GX6HT2 GXC6 GXC6T GXC6SC GXC9

Reference number 90800AW 90812AW 90814AW 90863AW 90850AW 90861AW 91142AW 89995AW Integral electrothermal shutter nn n n n n Integral pullcord shutter nn nn Integral adjustable run-on timer (2 to 20 mins) nn n n Humidity sensor (50-90% RH) nn Speeds 1 1 1 2 1 1 variable 1 Extract performance (FID, m3/h) high 266 266 266 266 266 266 260 549 low 222 83 Extract performance (FID, l/s) high 74 74 74 74 74 74 72 153 low 62 23 Sound pressure level (dB(A)@3m) high 37 37 37 37 37 37 34 44 low 34 25 Electrical power rating (W) 30 30 30 30 30 30 30 32 Hole diameter (mm) 184 184 184 184 184 184 184 257 Hole diameter with wall liner (mm) 203 203 203 203 203 203 203 266* Weight (kg) 1.9 1.9 1.9 1.9 1.9 1.9 1.9 3.9 Guarantee (years, UK) 3 33 33 3 33 *for wall kit WK9/8, increase to 330mm for WK9/11 40 Models Controllers

GX6 GXC6 Timer and Boost Switch TBS Ref. 90800AW Ref. 90850AW Ref. 90202AW • Single speed extract fan • Single speed extract fan • Switch 1: switches between humidity • Operated by remote switch or sensor • Integral pullcord switches fan On and control and manual operation (not supplied) opens shutter • Switch 2: High-low speed • Suitable for use with GXC6HT2 GX6T GXC6T Ref. 90812AW Ref. 90861AW Remote Humidistat XRH • Single speed extract fan • Single speed extract fan Ref. 21856AW • Integral run on timer (adjustable from • Integral pullcord switches fan on and • Stand alone humidistat switches fan On/Off 2-20mins) operated by lighting circuit opens electrothermal shutter when RH reaches pre-set levels • Pullcord off action actuates timer • Complete with pullcord override switch GX6HT overrun (adjustable from 2-20mins) then • Suitable for use with GX6 Ref. 90814AW closes shutter • Single speed extract fan Remote Time Controller DT20B • Integral automatic humidistat operation GXC6SC Ref. 21850AW adjustable between 50-90% RH Ref. 91142AW • Provides continued ventilation run-on • Integral run-on timer operated by the • Extract fan with adjustable speed control period after light has been switched Off lighting circuit • Integral pullcord switches fan On and • User adjustable run on timer (2-20 mins) • Timer adjustable from 2-20mins opens shutter • Built-in control allows performance to be set Passive Infrared Sensor XPIRA GX6HT2 to suit room size or use Ref. 21871AA Ref. 90863AW • Also suitable for professional speed • Activates fan via body movement. Ideal for • Two speeds and humidistat or manual adjustment where there is a fuel burning infrequently used public spaces. control selectable using an Xpelair TBS appliance in the room • Built in timer to prevent nuisance tripping control (not supplied) • Suitable for use with GX6 • Silent electrothermal shutter GXC9 features over the GX6 • Automatic humidistat operation adjustable Ref. 89995AW between 50-90% RH • Nine inch high performance extract • Integral run-on timer operated by room axial flow ventilation unit Typical Specifications on page 164. lighting circuit • As GX6 with integral pullcord Wiring Diagrams on page 183. • Timer adjustable from 2-20mins • Integral pullcord turns fan On and Remote Sensors on page 56. operates shutter Performance Dimensions (mm)

GX6/GXC6 GXC9

Range Range s n a f l a i x

Dimensions (mm) a

Model ABCD EF ØGHJK n

GX6, GXC6 226 210 119 107 109 101 184/203 32 4-35 112 e

GXC9 312 294 165 147 147 147 257/266 32 4-35 117 h c t Installation and Accessories i K | 9 C X G & 6 GX6/GXC6 GX6/GXC6 GXC9 GXC9 C

Wall Mounting Window Mounting Wall Mounting Window Mounting X G , Hole diameter: 203mm Hole diameter: 184mm Hole diameter: 266mm Hole diameter: 257mm 6 X Installation Accessories Installation Accessories Installation Accessories Installation Accessories G r

Wall Kit 200mm Ref. 89369AA Longer ladder strips* Wall Kit 200mm Ref. 89371AA Longer wall ladder strips* i

Wall Kit 280mm Ref. 89370AA Ref. 89382AA Wall Kit 280mm Ref. 89372AA Length 508mm a Longer ladder strips* Ref. 89382AA Longer ladder strips* Ref. 89382AA Ref. 89382AA l

Protective Wall Grille PG6 Protective Wall Grille PG9 *for walls/windows over 45mm thick, e

Ref. 89375AA Ref. 89376AA longer ladder strips are required p (see page 91) For exposed applications such as coastal use RX6, RX9 See page 94 X 41 Xpelair GX6 EC2 & GXC6 EC2 Kitchen and Utility room axial fans with UltraEC technology

Key features The Range

Type: Energy efficient UltraEC The new Xpelair GX6 range with Both models have a stylish white axial Window / Wall UltraEC technology - Energy efficient housing with integral safety finger fan with built in and long lasting. guard; GX6 has a silent backdraft backdraft shutter. shutter operation using an GX6 EC2 and GXC6 EC2 are electrothermal actuator; GXC6 shutter Application: Intermittent ventilation designed with installer selectable is pullcord operated. in kitchens, utility rooms. settings to satisfy Part F1 installed performances for intermittent GX6 EC2 and GXC6 EC2 models Control options: 1 speed selectable on installation or 2 speeds ventilation in kitchens or utility rooms. feature UltraEC offering reduced energy use, a choice of installed with COS switch Window or panel installation uses a performances and longer life than a ladder strip and external grille fitted with Legislation: Conforms to Building conventional AC motor. For this reason a gasket to provide a seal to the Regulations Part F1 & Xpelair offers a 5 year UK only mounting surface. For wall applications Scottish Building guarantee. Regulations for an additional wall sleeve assembly is intermittent use in recommended. kitchens and utility rooms.

Hole diameter: Window: 184mm Wall: 203 mm

Select the right product for your application

GX6 EC2 GXC6 EC2 Reference Number 92294AW 92295AW Longlife UltraEC motor Yes Yes Selectable speeds at installation 284m3/h = 10.6W 284m3/h = 7.9W 144m3/h = 7.1W 144m3/h = 3.4W Electric Power rating (W) 10.6 7.9 Sound pressure level (dB(A) @3m) 30.3 30.3 Integral electro-thermal shutter Yes Integral pullcord shutter Yes Hole diameter in window (mm) 184 184 Hole diameter using wall kit (mm) 203 203 Weight (kg) 1.9 1.9 Guarantee (Years UK) 5 5

42 Models

GX6 EC2 GXC6 EC2 Ref. 92294AW Ref. 92295AW • Extract fan with two installed performance options: installer selected • Extract fan with two installed performance options: installer selected

for Kitchens and Utility rooms for Kitchens and Utility rooms y g

• Operated by remote switch (not supplied) • Built-in pullcord On-Off operation o l

• 2 speed with COS • 2 speed with COS o n • Energy saving Longlife UltraEC external rotor motor with maintenance • Energy saving Longlife UltraEC external rotor motor with maintenance h

free sealed for life bearings and thermal overload protection free sealed for life bearings and thermal overload protection c e

• Integral safety finger guard • Integral safety finger guard t

• Integral mechanically operated louvred backdraft shutter with electro- • Integral mechanically operated louvred backdraft shutter with pullcord C thermal actuator On-Off actuator E a

• Inner grille and shutter cassette can be removed for easy cleaning • Inner grille and shutter cassette can be removed for easy cleaning r t l • Double insulated • Double insulated U h t

Performance i w s n a

60 f l

55 a i

50 x a 45 a P 40 m n i o e

r 35 o u r s

s 30 e y r t P

25 i l c i i t t a

t 20 S 15 U

10 d n

5 a Low Speed 0 High Speed n 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 e Flow rate in m3/h h c t i

Dimensions (mm) K |

Dimensions (mm) 2 A B C DE FØGHJK C 226 210 119 107 109 101 184/203 32 4-25 112 E

Typical Specifications on page 164. 6

Wiring Diagrams on page 183. C

Domestic Accessories on page 56. X G

Installation and Accessories &

GX6/GXC6 EC2 GX6/GXC6 EC2 2

Wall Mounting Window Mounting C E Hole diameter: 203mm Hole diameter: 184mm 6 Installation Accessories Installation Accessories X

Longer ladder strips* G Wall Kit 200mm Ref. 89369AA

Ref. 89382AA r

Wall Kit 280mm Ref. 89370AA i Longer ladder strips* Ref. 89382AA a

Protective Wall Grille PG6 l *for walls/windows over 45mm thick, longer

Ref. 89375AA e ladder strips are required p X 43 Xpelair Premier DX400 & CF40 Centrifugal extract and condensation control fans

Key features The Range

Kitchen ventilation has never looked so Control options include integral Application: Domestic kitchens, utility rooms and larger good. Since its launch, Premier has pullcord and timer. Models with an bathrooms; commercial taken the ventilation market by storm. integral humidistat offer automatic bathroom, small offices DX400 extract and CF40 condensation control. CF40TD features a delay start and public toilets. control fans are no exception. These ‘quick visit’ facility preventing the fan Suitable for surface and floor, wall and ceiling pressure developing centrifugal fans from coming on should the light be mounting are sleekly styled and are ideally suited switched on and then off within 2 for use in kitchens, utility rooms and minutes. Control options: Pullcord, timer and larger bathrooms and toilets and All models are IPX5 rated and BEAB humidistat individual offices. approved. They are all suitable for 220- Legislation: Conforms to Building They can be surface or flush mounted 240V 50Hz mains operation and Regulations Part F1 in walls and ceilings using the feature external rotor motors with universal mounting accessories integral balanced impellers, sealed for Hole diameter: 117mm provided, and include a back draught life maintenance free bearings and shutter and outlet grille. Both models safety thermal cut out protection. have their inlet discreetly concealed Optional filter is available see page 57. behind a stylish white front cover. This cover is held in position by clips for Select the right product for your application easy removal for cleaning.

DX400 DX400T DX400PC DX400RS CF40 CF40TD CF40RSTD Reference number 91083AW 91084AW 91100AW 91085AW 91086AW 91087AW 91088AW Remote switch (supplied separately) nn n Remote switch (supplied) n Integral pullcord nnn Integral adjustable run-on timer (30s to 20 mins) nnn Humidity sensor (50-90% RH) nnn Quick visit facility (2 minutes) nn Speeds 2 3 3 3 5 5 5 Trickle ventilation facility nn nn nn Extract performance (FID, m3/h) boost 250 250 250 speed 3 174 174 174 speed 2 245 245 245 245 143 143 143 speed 1 143 143 143 143 90 90 90 trickle 61 61 61 61 61 61 Extract performance (FID, l/s) boost 69 69 69 speed 3 48 48 48 speed 2 68 68 68 68 40 40 40 speed 1 40 40 40 40 25 25 25 trickle 17 17 17 17 17 17 Sound pressure level (dB(A)@3m) boost 55 55 55 speed 3 46 46 46 speed 2 55 55 55 55 40 40 40 speed 1 42 42 42 42 33 33 33 trickle 27 27 27 27 27 27 Electrical power rating (W) 78 78 78 78 77 77 77 Hole diameter 115 115 115 115 115 115 115 IP rating IPX5 IPX5 IPX5 IPX5 IPX5 IPX5 IPX5 Weight (kg) 3 3 3 3 3 3 3 Guarantee (years, UK) 3 3 3 3 3 3 3

44 Models Controllers

Premier DX400 • Fan running status lights Manual Override Switch MOS Ref. 91083AW • Includes external wall grille Ref. 90199AW • Two speed centrifugal fan • Switch 1 controls the high/low speed levels and • Pre-select speed to suit application Premier CF40 Switch 2 controls On/Off and the tricklevent option • Alternatively use optional COS switch to Ref. 91086AW change between speeds and On/Off • Condensation Control Range with • Includes external wall grille humidistat • Automatic operation through integral

Premier DX400T humidity sensor s

Ref. 91084AW • Pullcord selects High, Low, Off or Trickle n

• Centrifugal fan with timer a • Timer is typically connected to a lighting circuit Premier CF40TD f • Built in run-on period after the light has Ref. 91807AW l

• Automatic operation through integral Change Over Switch COS o

been switched Off, user adjustable from r 30s-20min humidistat Ref. 90108AW t • Fan operates at full speed when light is On, • Pullcord selects High, Low, Off or Trickle • Used to select between high and low speed n

• ‘QuickVisit’ delay feature prevents the fan o then operates at reduced speed during run-on operation

from running should the light be switched c and the switches to either Trickle or Off On/Off again within two minutes (installer selectable) Remote Humidistat XRH • Fan running status lights n • ‘QuickVisit’ delay feature prevents the fan Ref. 21856AW • Includes external wall grille o from running should the light be switched i • Stand alone humidistat switches fan On/Off t On/Off again within two minutes Premier CF40RSTD when RH reaches pre-set levels. Complete a • Fan running status lights Ref. 91088AW with pullcord override switch s • Includes external wall grille

• Automatic operation through integral humidistat n

• MOS remote switch (supplied) selects high Remote Time Controller DT20B e Premier DX400PC or low speed and can switch the unit Off (or Ref. 21850AW d Ref. 91100AW to tricklevent). • High, Low, On/Off with tricklevent operated • Built in humidity control run on period • User adjustable run-on timer (2-20mins) n by integral 3 position pullcord switch • User adjustable from 30sec-20min o Passive Infrared Sensor XPIRA c • Fan running status lights • Fan running status lights • Includes external wall grille Ref. 21871AA

• Includes external wall grille d • Activates fan via body movement Premier DX400RS n Note: For kitchen applications a grease filter • Ideal for infrequently used public spaces Ref. 91085AW PDXGF is recommended Ref. 91145AA a

• Two speed centrifugal fan • Built in timer to prevent nuisance tripping t

• Pre-select speed to suit application c

• Alternatively use optional COS switch to a

Typical Specifications on page 165. r

change between speeds and On/Off t Wiring Diagrams on page 183. • Trickle vent option is activated by a preset x

switch on the unit Remote Sensors on page 56. e l Performance Dimensions (mm) a g

DX400 Range CF40 Range u DX400/CF40 Range f i r t n e 100 C | 0 100Ø Spigot 4 F C d n a

Installation and Accessories 0 0 4 X D r e i m

Wall Mounting Ceiling Mounting Ducted Applications Ventilation Shaft Mounting e r

Hole diameter: 117mm Hole diameter: 117mm Hole diameter: 117mm P Ducting size: 100mm Ducting size: 100mm Ducting size: 100mm r Installation Accessories Installation Accessories i a Easy fit kit EFT Ref. 90427AA Flat ducting XFP see Profile 60 l Wall Tube WD100 Ref. 89543AA Flexible ducting FD100 Ref. 89910AA e

Condensation trap XCT100 Ref. 89749AA p Vent cowl VC10 Ref. 89531AA X Ceiling mounting kit XCMK Ref. 90066AA 45 Xpelair Premier CF20/40T CV Centrifugal extract and condensation control fansNEW NEW

Key features The Range

Type: Constant Volume The Premier CF20/40T CV model constant irrespective of the installed UltraEC Centrifugal features UltraEC technology offering condition up to a system pressure of extract fan reduced energy use, a choice of 100Pa. The fan can be surface or installed performances and a longer flush mounted in walls and ceilings Application: Intermittent ventilation, life than a conventional AC motor. using the universal mounting accessories provided. Humidity controlled The fan is designed to comply with the intermittent ventilation, requirements of Part F1 to provide The fan is provided with a back Decentralised Intermittent Ventilation in Kitchens, draught shutter for intermittent ventilation Utility rooms, Bathrooms and Sanitary applications. It is not to be fitted for the Rooms, Humidity Controlled lower velocity continuous decentralised Control options: Installer selectable intermittent Ventilation + manual over- applications. Control options include humidistat, timer and ride in Kitchens and Bathrooms, integral Humidistat, pullcord over-ride, pullcord override Intermittent Ventilation in Internal rooms run on timer and 'quick visit' delay and Decentralised Continuous start facility. Xpelair offers a 5 year UK Legislation: Conforms to Building Ventilation in Kitchens, Utility Rooms, only guarantee. Bathrooms and Sanitary Rooms. Regulations Part F1 Performance is set at installation via a Hole diameter: 115mm series of internal dip switches. The Constant Volume nature of the fan means that performance remains

Select the right setting for your application At Zero Static Pressure*

Speed Settings Extract Performance Noise dB(A) @ 3m Power (W)

Intermittent Ventilation l/s m3/h Kitchen 60l/s 216m3/h via integral pullcord 55.8 31W Utility 30l/s 108m3/h via integral pullcord 39.9 8.4W Bathroom 15l/s 54m3/h via integral pullcord 22.7 4.9W Sanitary Room 6l/s 22m3/h via remote switch (not supplied) 20.8 4.2W Humidity Controlled intermittent Ventilation + manual over-ride Kitchen 60l/s 216m3/h Off. Humidity. pullcord 55.8 31W Bathroom 15l/s 108m3/h 216m3/h Off. Humidity. pullcord 22.7 4.9W Intermittent Ventilation - Internal Rooms Kitchen 60l/s 216m3/h + 15min over-run timer triggered via light switch 55.8 31W Utility 60l/s 216m3/h + 15min over-run timer triggered via light switch 55.8 31W Bathroom 15l/s 54m3/h + 15min over-run timer triggered via light switch 22.7 4.9W Sanitary Room 15l/s 54m3/h + 15min over-run timer triggered via light switch 22.7 4.9W Decentralised Continuous Ventilation Kitchen 13l/s 20.8 4.6W Utility 8l/s 21.4 4.4W Bathroom 8l/s 21.4 4.4W Sanitary Room 6l/s 20.8 4.2W *Measured with 300mm of ducting and wall grille fitted on the outlet side. Note: As this is a constant volume product, as the back pressure on the system increases so the motor increases speed to maintain airflow. This has the effect of increasing motor input power. Product is rated at 230V, 50/60Hz, single phase. 46 W Easy fitkitEFT Installation Accessories 100mm Ducting size: Hole diameter: Wall Mounting Externalrotormotorwithintegralbalanced • • • R Premier CF20/40TCV Fan maintainsselectedextractvolume • Installation andAccessories Models Performance ef.92293AW all Tube WD100 b impellers, sealedforlifemaintenancefree UltraEC longlifelowenergymotor switches. selectable atinstallationbymeansofdip Constant Volume centrifugalfanwithspeed t irrespective ofsystemresistanceup o o ut protection earings andsafetythermalcut 100Pa 117mm Ref Ref. 90427AA . 89543AA Includesexternalwallgrilleandfanbackdraft • • • • BuiltinHumidistatcontrolledintermittent • s l c 'Quick visit'featurepreventsthefan compliance withPart F1 s ( Run onperiodof20sec-20min option forinternalrooms Built intimercontrolledintermittentventilation v ess thantwominutes installer adjustable)afterlighthasbeen entilation option hutter forintermittentapplications witched Off.Factory setat15minin oming oniftheroomisoccupiedfor ltdcigXPsee Ceiling mountingkit XCMK Vent cowlVC10 Condensation trap XCT100 Flexible ductingFD100 Flat ductingXFP Installation Accessories 100mm Ducting size: Hole diameter: Ceiling Mounting 117mm utdApiain Ventilation ShaftMounting Applications Ducted Ref. 90066AA Ref. 89531AA Ref. 89749AA Ref . Dimensions (mm) Profile 60 89910AA R Wiring Diagrams Typical Specifications emote Sensors utn ie 100mm Ducting size: Hole diameter: o on page181. n page 56. on page161. 117mm 47

Xpelair Premier CF20/40T CV | Centrifugal extract and condensation control fans

Xpelair Nouvelle Cuisine Kitchen canopies

90 Curved

Key features The Range Models

For many households the kitchen is the Type: Kitchen canopy 90 Curved busiest room in the home. As well as an Ref. 91202AW area for cooking, it is often the main focal Description: 90cm Curved Glass Canopy Application: Domestic kitchens point for family and guests. Finish: Stainless Steel and Glass Duct size: 125mm Control options: Integral But with cooking odours, steam and condensation continually building up, Features / Specification Legislation: Conforms to Building keeping the kitchen fresh and pleasant is • 90cm Curved Glass Canopy Regulations Part F1 a constant problem. The Nouvelle • 3 speed levels Cuisine range of kitchen canopies is • Stainless steel finish elegantly designed to suit every kitchen • Recirculation or extraction • Maximum extraction rate 480m3/h design and budget. • Electronic touch control Using powerful extraction and filters every • 200W motor model in the range will keep rooms free of • Twin 50W halogen spotlights steam and odour – leaving behind a fresh • Aluminium grease filter • Optional carbon filter system and comfortable environment. Dimensions Crafted from high quality materials such as stainless steel and glass and equipped with push button controls and built-in spotlights, the Nouvelle Cuisine kitchen canopies are a stylish addition to any kitchen.

With wall fix, island and built-in models available, the Nouvelle Cuisine range provides flexibility and choice for the Typical Specifications on page 165. Wiring Diagrams on page 183. perfect fit, practicality and ease of use.

Splashbacks 60 70 90 100 110 90 Curved

Reference number 91204AW 91205AW 91206AW 91207AW 91208AW Reference number 91202AW Finish stainless steel stainless steel stainless steel stainless steel stainless steel Freestanding n Size (mm) w600 x h750 w700 x h750 w900 x h750 w1000 x h750 w1100 x h750 Max extraction performance (l/s) 133 Sound pressure level* (dB(A)) 39 Motor rating (W) 200 Speeds 3 Recirculation n Extraction n Duct size (mm) 125 No. grease filters 1 Grease filter type aluminium Built-in lighting 2 x 50W Maximum width (mm) 900 Finish stainless steel & glass Replacement filters 41834SK *at low speed 48 Optionalcarbonfiltersystem • Aluminiumgreasefilter • • 240Wmotor • Electronictouchcontrol • Maximumextractionrate851m • Recirculationorextraction • • • 90cmIslandGlassCanopy • F D Finish: StainlessSteelandGlass D 91203AW Ref. 90 Island eatures /Specification Models escription: 90cmIslandGlassCanopy uct size:125mm Dimensions (mm) F Stainless steelfinish 3 our 50Whalogenspotlights speed levels tils te ls sanessel&gas tils te ls sanessel&gas stainlesssteel&glass stainlesssteel&glass stainless steel&glass stainlesssteel&glass stainless steel&glass lmnu lmnu lmnu lmnu aluminium aluminium aluminium aluminium aluminium 0Iln 0Fa 0Fa 0Bx90 Box 70 Box 90Flat 60Flat 90 Island 13S 13S 13S 13S 41834SK 41834SK 41834SK 41834SK 41834SK 91203AW 90 Island 4 x 0 0 0 0 2x40W 2x40W 2x50W 2x50W 50W 2 2 2 2 125 200 133 125 200 133 125 200 133 125 200 133 900 125 240 236 44 nnnnnn nnnnn 1 33333 3 /h • 60/90cmFlatGlassCanopies • F Duct size:125mm Finish: StainlessSteelandGlass Description: 60/90cmFlatGlassCanopies 91200AW /Ref. 91201AW Ref. 60 /90Flat • 200Wmotor • Electronictouchcontrol • Maximumextractionrate480m • Recirculationorextraction • • Optionalcarbonfiltersystem • Aluminiumgreasefilter • e atures /Specification 3 T Stainless steelfinish win 50Whalogenspotlights speed levels 91200AW 600 39 n 1 60 /90Flat * 91201AW 3 /h 90 Flat=900mm 60 Flat=600mm 900 39 n 1 Duct size:125mm F Description: 70/90cmBoxCanopies 91198AW /Ref. 91199AW Ref. 70 /90Box • • Stainlesssteelfinish • 3speedlevels • 70/90cmBoxCanopies • Features /Specification Optionalcarbonfiltersystem • • • • buttoncontrolpanel Push • inish: StainlessSteel Maximum extractionrate480m Recirculation orextraction T Built intwinlights 200W motor win aluminiumgreasefilters 91198AW 0 900 700 39 70 /90Box n 2 * 90 Box=900mm 70 Box=700mm 91199AW 3 /h 39 n 3 49

Xpelair Nouvelle Cuisine | Kitchen canopies Xpelair Nouvelle Cuisine Kitchen canopies

Tonda

Chimney

Inset

Models

60 / 90 Tonda 60 / 90 Chimney Inset Ref. 91196AW / Ref. 91197AW Ref. 91194AW / Ref. 91195AW Ref. 91192AW Description: 60/90cm Tonda Canopies Description: 60/90cm Chimney Canopies Description: 60cm Inset Canopy Finish: Stainless Steel Finish: Stainless Steel Colour: Silver Duct size: 125mm Duct size: 125mm Duct size: 125mm Features / Specification Features / Specification Features / Specification • 60/90cm Tonda Canopies • 60/90cm Chimney Canopies • 60cm Inset Canopy • 3 speed levels • 3 speed levels • 3 speed levels • Stainless steel finish • Stainless steel finish • Available in silver finish • Recirculation or extraction • Recirculation or extraction • Recirculation or extraction • Maximum extraction rate 480m3/h • Maximum extraction rate 480m3/h • Maximum extraction rate 229m3/h • Sliding control panel • Push button control panel • Sliding control panel • 200W motor • 200W motor • 140W motor • Built in twin lights • Built in twin lights • Built in twin lights • Twin aluminium grease filters • Twin aluminium grease filters • Carbon filter system • Optional carbon filter system • Optional carbon filter system • Acrylic grease filter in metal grid casing

Dimensions

* 60 Tonda = 600mm * 60 Chimney = 600mm 90 Tonda = 900mm 90 Chimney = 900mm

60 Tonda 90 Tonda 60 Chimney 90 Chimney Inset

Reference number 91196AW 91197AW 91194AW 91195AW 91192AW Freestanding n n nn Integrated n Max extraction performance (l/s) 133 133 133 133 64 Sound pressure level* (dB(A)) 39 39 39 39 55 Motor rating (W) 200 200 200 200 140 Speeds 3 3 3 3 3 Recirculation n nn nn Extraction n n n n n Duct size (mm) 125 125 125 125 125 No. grease filters 2 2 2 2 1 Grease filter type aluminium aluminium aluminium aluminium acrylic filter in metal casing Built-in lighting 2 x 40W 2 x 40W 2 x 40W 2 x 40W 2 x 40W Maximum width (mm) 600 900 600 900 525 Finish stainless steel stainless steel stainless steel stainless steel silver Replacement filters 41834SK 41834SK 41834SK 41834SK 41832SK *at low speed

50 o raefles1112 600 41832SK 2x40W 125 1 600 41834SK 2x40W 52 125 600 40 1 41834SK 2x40W 125 aluminium 41833SK 600 2x40W 40 1 acrylicfilterinmetalcasing acrylic filterinmetalcasing 200 acrylicfilterinmetalcasing 39 *at lowspeed Replacement filters Finish Maximum width(mm) Built-in lighting Additional carbonfiltersystem Grease filtertype No. grease filters Duct size(mm) Extraction Recirculation Speeds Motor rating(W) Sound pressure level*(dB(A)) Max extractionperformance(l/s) Integrated Freestanding R Optionalcarbonfiltersystem • Metallicgreasefilterinaluminiumgrille • • 125Wmotor • Slidingcontrolpanel • • • • 3speedlevels • 60cmIntegratedCanopy • Features /Specification Duct size:125mm Colour: Silver Description: 60cmIntegratedCanopy R I ntegrated efer Models f 91193AW ef. Dimensions (mm) Built intwinlights Maximum extractionrate480m Recirculation orextraction Available insilverfinish ence number Integrated 3 /h Duct size:125mm Colour: WhiteorBrown Description: 60cmStandardCanopy • • F Ref. 91190AB 91189AW Ref. Standard Acrylic greasefilterinmetalgridcasing • • Builtintwinlights • 125Wmotor • • Maximumextractionrate320m • Recirculationorextraction • • eatures /Specification nertdSadr tnadStandardPlus Standard Standard Integrated 91193AW 3 60cm StandardCanopy Additional carbonfiltersystem Sliding controlpanel A optional vailable inwhiteorbrownfinish speed levels silver 125 97 nnnnn nnnn n 3 - - Brown White S tandard 91189AW 3 /h ht rw stainlesssteel brown white 125 56 n nnn 3 Duct size:125mm Finish: StainlessSteel Description: 60cmStandardPlusCanopy 91191AW Ref. Standard Plus • 60cmPlusCanopy • F Maximumextractionrate200m • • • • • Builtintwinlights • • Slidingcontrolpanel • eatures /Specification 3 Recirculation orextraction Stainless steelfinish recirculation only Additional carbonfiltersystemfor T 125W motor win aluminiumgreasefilters speed levels Standard Plus 91190AB 2 125 125 656 56 n 33 3 /h 91191AW n 51

Xpelair Nouvelle Cuisine | Kitchen canopies Xpelair Profile 60 Flat ducting system

Key features The Range

Type: Low profile flat Where space is limited for conventional Profile 60 components are plastic ducting duct systems, Xpelair Profile 60 manufactured in flame retardant PVC provides an innovative solution to conforming to DIN4102/B1.M1. The Application: Kitchen canopies & connect internally fitted extract units to lightweight and easy to handle straight Premier range, the outside world. duct can be cut to length using a particularly DX400 conventional cross cut saw and the A common problem when fitting & CF40 system includes a full range of vertical ductwork in the average kitchen is the and horizontal bends for easy lack of space left by large kitchen Size: 204 x 60mm plastic installation. cupboards. The Profile 60 provides the ideal solution – an adaptable, Quick-fit support clips hold the system Installation: Simple push fit & lightweight system that can be tailored in place and the whole system can be easily concealed to fit individual room layouts. concealed behind plasterboard for discreet functionality. Fast and easy to install, the clean white components of the system can be wall Profile 60 is designed to work with a or ceiling mounted. It can be fitted number of kitchen canopies, between concrete floor slabs and wholehouse systems and extract plasterboards ceilings, as vertical risers systems to make up the complete in stud partitioning or under the floor. ducting solution.

Typical installation with Typical kitchen canopy installation Premier DX400

52 Profile 60 Flat Plastic Ducting - w204 x h60mm

Product Product Ref Description Dimensions (mm) Spigot Ø ID (mm) Ref.

FPD100 Flat ducting, 1 metre length 204 x 60 89755AA FPD150 Flat ducting, 1.5 metre length 204 x 60 91188AA

FPA Horizontal bend adjustable 204 x 60 89750AA

FPG Wall outlet grille 204 x 60 89751AA

FPP100 Elbow / Plenum box 204 x 60 100 89752AA

FPP125 Elbow / Plenum box 204 x 60 125 91259AA

FPP150 Elbow / Plenum box 204 x 60 150 91483AA

FPV90 Vertical 90º bend 204 x 60 89753AA

FPH90 Horizontal 90º bend 204 x 60 89754AA

FPB Mounting bracket (boxed in 5’s) 204 x 60 89756AA

FPC Coupling 204 x 60 89757AA

FPT T piece 204 x 60 90091AA

FPF Flexible ducting, 0.5m 204 x 60 91484AA

PFB Intumescent type fire break 204 x 60 91975AA m e t

PRA Round to rectangular adaptor 204 x 60 125 91482AA s y s

Dimensions (mm) Additional Accessories g n i t

Acoustic Airbrick XAAB Ref. 91166AA Condensation Trap XCT100 c

Ref. 89749AA u Acoustic Airbrick XAABW with white grille

• For use with 100mm diameter ducting d Ref. 91162AA

• Prevents condensed water running back t

towards the fan in vertical PVCu ducted a

Acoustic Airbrick XAABB with brown grille l applications

Ref. 91163AA F Profile 60 • Collected water must be piped away to a Acoustic Airbrick XAABC convenient disposal point Flat channel outer dimensions are with Cotswold stone grille Ref. 91164AA • 20mm outlet | w204 x h60mm and fit into system

Acoustic Airbrick XAABT Fire XFC100 0 parts sockets. with terracotta grille Ref. 91165AA Ref. 89843AA 6 • Suitable for use adjacent to noise nuisance • Provides 1 hour fire check in either direction Cross section: 11200mm2

areas including roads, railways and airports • Can be mounted at any angle e

• Weighted Sound Reduction Index Rw BS EN • For ducts, walls and ceilings. Should not be l i

ISO717-1:1997 = 7 fitted into flexible ducting. Wall or duct in which f XFC is fitted should have a rated fire integrity in Ceiling Kit XCMK o accordance with Building Regulations Part B r Ref. 90066AA • Use with ceiling mounted ducted products 100mm Xflex FD100 P

• Complete with tube, rubber gasket and foam strip Ref. 89663AA r • Wire helix flexible ducting i

• 3m length a Minimum space required for l installation: w210 x h65mm Typical Specifications on page 165. e p X 53 Xpelair CX10 & CMF Ceiling mounted fans

CX10

CMF

Key features The Range

Type: Ceiling mounted axial Where wall space is tight or at a In many commercial applications such and centrifugal fans premium, fitting an extraction system as kiosks, retail clothing changing drawing air from the ceiling is the booths and copying rooms where heat Application: Domestic kitchens, convenient and secure solution. Whats build up is a problem it may be bathrooms and more, ducted ceiling extract systems sufficient simply to dilute the air about shower rooms free you to position the unit for the ceiling. maximum benefit. The CX10 is especially suitable for Legislation: Conforms to Building Suitable for domestic kitchens, larger applications and short duct Regulations Part F1 utility rooms and power shower rooms. runs. CMF models are ideal for longer Light commercial applications include ducted extract systems. Hole diameter: 300mm (CX10) customer waiting areas, changing 185sq (CMF171) Shallow in depth, several models will fit rooms, payment and ticket kiosks, 248sq (CMF241) between the ceiling of the room and smoking rooms, office kitchens, 273sq (CMF271) the floor above. In many of these storage rooms, small meeting rooms applications it is good practice to and offices. Commercial applications consider sensor control, operating include pub bars, factories, schools automatically and only when and shops. necessary, saving energy. Flush mounted, Xpelair CX10 and All models are suitable for high CMF units have a white finish to blend humidity applications and have an into the ceiling décor. unobtrusive flush design with finger- Behind this neat fascia are efficient fan guard protection. Lubricated for life units, which connect directly to Xflex motors, with maintenance free bearings ductwork to exhaust to the outside. and safety thermal overload protection The CX10 units are axial fans and the are standard across the range. CMF units are pressure developing centrifugal fans.

Select the right product for your application

CX10 CMF171 CMF241 CMF271

Reference number 90209AB 89955AW 89956AW 89957AW Remote switch (not supplied) n n n n Extract performance (FID, m3/h) 329 63 146 286 Extract performance (FID, l/s) 91 18 41 79 Sound pressure level (dB(A)@3m) 44 38 41 41 Electrical power rating (W) 34 30 33 48 Hole diameter (mm) 300 185x185 248x248 273x273 Ducting size (mm) 200 102 102 150 Weight (kg) 1.8 2.7 3.8 6.9 Guarantee (years, UK) 3 3 3 3

54 Models

CX10 CMF 171 Ref. 89955AW Tip Ref. 90209AB CMF 241 Ref. 89956AW • In situations where there is a tight closing • Single speed axial flush mounted extract CMF 271 Ref. 89957AW bathroom or kitchen door, air circulation can ceiling fan with stylish circular flush design. • Flush mounted extract ceiling fans be prevented. To remedy the situation fit a • Unit comes complete with integral finger- • High performance single speed centrifugal slimline air-grille in white (89529AA) or brown guard and fly screen pressure developing motor/fan/scroll (89530AA) in door thicknesses up to 35mm. • Lightweight two piece construction assemblies • Moulded pre-balanced axial bladed impeller • Stylish square grille design with integral • Suitable for steam and condensation finger-guard applications • Lightweight two piece construction with • Vertical spigot with 200mm diameter horizontal spigot outlet Typical Specifications on page 166. connection • Cassette design allows ducting to be Wiring Diagrams on page 183. • Operated by remote switch or sensor installed prior to the fan itself Remote Sensors on page 56. (not supplied) Performance Controllers

CX10 Range CMF Range Remote Humidistat XRH Ref. 21856AW • Stand alone humidistat switches fan On/Off when RH reaches pre-set levels. Complete with pullcord override switch

Remote Time Controller DT20B Ref. 21850AW • User adjustable run-on timer (2-20mins)

Passive Infrared Sensor XPIRA Ref. 21871AA • Activates fan via body movement. Ideal for infrequently used public spaces. Built in timer to prevent nuisance tripping

Dimensions (mm)

CX10 CMF Range s n a Dimensions (mm) f

Model A B C D E d e

CMF171 277 226 123 230 240 t

CMF241 343 260 133 290 319 n

CMF271 420 318 133 320 350 u o m

Installation and Accessories g n i l i

Please be aware that fan performance will e be affected by the use of ducting, grilles C and shutters. | Termination Ducting Kit TDK8

Ref. 89384AA F • For use with CX10 • Roof space ducting kit from fan to soffit M

board. C • Comprised flexible ducting, exterior grille, CX10 CMF Range duct tie and fixings & • 2.5m duct length comprising 0.5m formed 0 rectangular and 2m of 200mm diameter Ceiling Mounting Ceiling Mounting 1 • Grille dimensions 294 x 193mm

Hole diameter: 300mm Hole diameter: 185 x 185mm (CMF171) X Ducting size: 200mm 248 x 248mm (CMF241) 273 x 273mm (CMF271) C

Ducting size: 102mm (CMF171/241) r i Installation Accessories 150mm (CMF271) a l Termination Ducting Kit TDK8 e Ref. 89384AA p X 55 Xpelair Domestic Sensors & Switches

Remote Humidistat XRH LoVolt Remote Humidistat LVH Time delay unit DT20B Ref. 21856AW Ref. 21863AW Ref. 21850AW

• Automatically switches On when the • A 12V SELV LoVolt humidistat • Connected to a switching circuit such as relative humidity reaches an adjustable • Automatically switches On when the a bathroom lighting preset point and switches off when the relative humidity reaches an adjustable • Provides adjustable run on time delay relative humidity drops pre set point and switches Off when the after the light has been switched Off • Pullcord override switch relative humidity drops • Time adjustable up to 20 minutes • Fan indicator light • Pullcord override switch • Surface or recess mounting • Surface or recess mounting • Fan indicator light • Suitable for ambient temperature up • Suitable for ambient temperatures up • Surface or recess mounting to 40ºC to 40ºC • Suitable for ambient temperatures up • Supply voltage 200 - 240V 50Hz • Supply voltage 220-240V 50Hz to 40ºC • Used with: Premier DX180, DX200, DX400, • Used with: Premier DX180, DX200, DX400, • Supply voltage 12V SELV DX100, XIL, CMF, CX10, LoVolt DX100 DX100, XIL, CMF, CX10, GX6 • Used with: Premier LoVolt DX200, • w100 x h86 x d45 mm • w160 x h86 x d45 mm LoVolt CF20, LoVolt DX100 • w160 x h86 x d45 mm

Change Over Switch COS Manual Override Switch MOS Passive Infrared Sensor XPIRA Ref. 90108AW Ref. 90199AW Ref. 21871AA

• Used to select between high and low • Switch 1:high/low speed • For indoor use speed operation • Switch2: On/Off (or Off/tricklevent • Automatically switches a fan on when • Surface or recess mounting according to fan option selected) body movement is detected • Used with: DX400, DX400T, DX400RS • Surface or recess mounting • Incorporates a delay timer • w85 x h85mm • Used with: Premier DX200 and Premier • Supply voltage 220-240V 50Hz DX400, DX400RS in conjunction with XRH • Used with: Premier DX200, DX400, DX100, Remote Humidistat. CMF, CX10, GX6 • w85 x h85mm • w86 x h86mm

Timer and Boost Switch TBS Air Quality Sensor AQS Ref. 90202AW Ref. 92097AW • Provides fully automatic control • Provides switching between humidity • Detects contaminants such as cigarette smoke, control / manual operation body odours, toilet odours and cooking smells • Provides selection of high / low extract speed • Activates ventilation system when preset • Surface or recess mounting threshold level is exceeded • Used with: GX6HT2 • Can control up to six fans and accessories • w85 x h85mm • Integral timer adjustable from 3 - 30 mins • LED status indicator • Surface or recess mounting 56 • Supply voltage 220-240V 50Hz • w210 x h86 x d41mm Xpelair Domestic Accessories

Flexible Ducting Xflex FD Thermal Flexible Ducting Xflex TFD New Aluminium Flexible Ducting Xflex ALU Dia Length Dia Length Dia Length FD100 100mm 3m Ref. 89663AA TFD100 100mm 5m Ref. 89847AA ALU100 100mm 10m Ref. 91435AA 6m Ref. 89669AA 10m Ref. 91459AA ALU125 125mm 10m Ref. 91436AA FD125 125mm 3m Ref. 89664AA TFD125 125mm 5m Ref. 89848AA ALU150 150mm 10m Ref. 91437AA 6m Ref. 89670AA 10m Ref. 91460AA ALU200 200mm 10m Ref. 91438AA FD150 150mm 3m Ref. 89665AA TFD150 150mm 5m Ref. 89849AA 6m Ref. 89671AA 10m Ref. 91461AA • Tough foil construction on a high strength FD200 200mm 3m Ref. 89666AA TFD200 200mm 5m Ref. 89850AA wire helix 6m Ref. 89672AA 10m Ref. 91462AA • Over 40 minute fire rating BS 476: Part 20 (1987) • Glass fibre fabric on a PVC coated close • Double skinned insulated aluminium pitch steel wire helix. 54 minute fire duct with high density fibreglass integrity from within as measured to BS insulation to minimise condensation 476:Part 20 - (1987) formulation • Can be interlocked and sealed with duct • 25 minute fire integrity from within as tape to form an airtight seal. Attached to measured to BS 476: Part 20 - (1987) spigots using worm drive clips • Can be interlocked and sealed with duct tape to form an airtight seal s e i r o s s e c c A & s e h c

Worm Drive Clips WDC Premier Grease Filter PDXGF 100mm Wall Duct WD100 t i WDC5 For Premier DX200 models Ref. 89543AA w Ref. 89684AA Ref. 90548AA S Dia.100-125mm For Premier DX400 models • For bridging cavities or lining solid , Ref. 91145AA exterior walls • Mortared into position s WDC8 r • For Premier units in kitchen applications • Used with: Premier DX200, CF20, o Ref. 89685AA • Fits behind the inlet Premier DX400, CF40 s Dia. 150-200mm • Material: Self extinguishing black • The premier models above come complete n polyester foam with external grille. Premier DX180 also e • For connection of flexible ducting to spigots requires wall grille • Supplied in packs of 10 • Dia. 100mm S • Length 300mm c i t s e m o D r i a l e p X www.xpelair.co.uk 57 Xpelair Domestic Accessories

Fire Damper XFC Vent Cowl VC10 Glass Mounting Kits GMK & DXDG XFC100 Dia. 100mm Ref. 89843AA Ref. 89531AA Premier glass mounting kit GMK XFC125 Dia. 125mm Ref. 89844AA Ref. 90546AA XFC160 Dia. 150mm Ref. 89845AA • Provides weather protection for a XFC200 Dia. 200mm Ref. 89846AA 100mm PVCu rigid ducted outlet • Used for installing Premier DX180, DX200 • Pushfit and should be secured with • For ducts, walls and ceilings. Should not be fitted and CF20 models in a window solvent adhesive into flexible ducting. Wall or duct in which XFC is • Glass thickness: 4-28mm • Material: PVCu fitted should have a rated fire integrity in accordance with Building Regulations Part B • Colour: Grey DX100 double/triple glazing kit DXDG • Provides full 1 hour fire check • Used with: Premier DX180, DX200, DX400, Ref. 07439AA • Closing temperature 72OC DX100 axial models in exposed situations. • Low temperature drop • Cowl diameter: 200mm • Allows DX100/LV100 to be mounted in • Tested at Warrington Fire Research Centre • wØ201 x h101 x inner Ø110mm double glazed panels from 6 to 46mm thick to BS476 Part 20

GX Wall Kit WK Condensation Trap XCT100 Easy-Fix Termination Kit EFT For GXC9 models Ref. 89749AA Ref. 90427AA Ref. 89372AA • For use with 100mm dia ducting • Designed to be installed from inside a For GX6/GXC6 models • Prevents condensed water running building through a cored out to Ø115mm Ref. 89370AA back down the duct towards the fan in (nominal) hole drilled in brickwork vertical PVCu pipe ducted applications. • Easily cut to length • For bridging cavity walls or lining solid double (Not suitable for use in a flexible duct run) • Simple installation save times and cost brick walls • Collected water must be piped to a • Four sealing rings provide a watertight • Steel wall liner. Length 280mm convenient disposal point seal in the external wall • Set of 508mm ladder strips • Colour: Grey • Used with: Premier DX180, DX200, CF20. • Ø255mm • 20mm drain off point Not suitable for 100mm axial fans • Hole diameter: 267mm • Material: PVCu • Length: 465mm • Length: 85mm

Airbrick Adaptor XAA Spigot Plate SP100 Ceiling Kit XCMK Ref. 89777AA Ref. 89697AA Ref. 90066AA

• A fabricated G.S.M 340mm sleeve to • Connects a duct to the wall face • Allows a sealed ceiling mounting of bridge a cavity and line a solid wall • 100mm spigot ducted products • Connects to 100mm duct • Material: Plastic • Compete with ceiling adaptor tube • Includes an air brick • Used with: All ducted 100mm fans. 105.7m dia, rubber gasket and foam strip • GSM adaptor • For larger diameter spigot plates see page 81 • Used with: Premier DX180, DX200, DX400 • Used with all 100mm fans. • w180 x h180 x Ø96.5 • w220 x h65 x d340 Ø100mm

58 Xpelair Domestic Accessories

Wall Grille Gravity Shutter XXWG4 Wall Kit XXSWK4 Wall Grille CFWG White Ref. 90174AW Ref. 90333AW CFWG100 - Grey Ref. 89215AB CFWG100 - White Ref. 89742AW Grey Ref. 90140AA CFWG150 - Grey Ref. 89690AB • 100mm wall kit consists of wall duct, CFWG150 - White Ref. 89857AW • Protected duct outlet fitted with gravity flaps internal and external grilles foam strips and wall fixings • 100mm dia connection • Surface mounted exterior wall outlet grille • Used with: XXS100 • Dimensions: w155 x h155 x d15mm • For use with 100mm / 150mm nominal • Wall hole dia. 117mm size ducting • Fixing screws provided • Use with: 100mm axial variants. • Dimensions: w150 x h150 x d13mm (CFWG100) w217 x h217 x d24mm (CFWG150) s e i r o s s

Wall Vent Kit VK10 Termination Ducting Kit WT Exterior Storm Cowl XXSCW XXSCB e

Ref. 89120AW WT10 100mm Ref. 89538AA XXSCW White Ref. 90461AW c

WT15 150mm Ref. 89687AA XXSCB Brown Ref. 90462AB c • To bridge a cavity or line a solid wall hole A • Complete with wall duct (WD), 155mm • For use in through wall applications, ducting • Provides protection against severe square external back-draught shutter, foam can be terminated on the spigot backdraughts and water ingress & strip and wall fixings • Complete with exterior wall grille (CFWG), wall • Fitted with gravity flap damper

• Grille w155 x h155 duct (WD), spigot plate (SP), fixing screws • Wall mounted s

• Wall hole dia. 117mm and plugs • 100mm spigot e

• Wall hole dia. 117mm • Used with: 100mm axial fans. h c t i w S , s r o s n e S

Air Replacement Door Grilles DG-W DG-B Slimline Wall Kit SLWK Slimline Window Kit SLGK c DG-W White Ref. 89529AA i SL100 Wall Kit Ref. 91232AW SL100 Window Kit Ref. 91234AW t

DG-B Brown Ref. 89530AA SL150 Wall Kit Ref. 91233AW SL150 Window Kit Ref. 91235AW* s e • Tight closing bathroom / toilet doors • Wall kit consists of wall duct and external grille • Window kit consists of internal housing and prevent air circulation to the fan. Air • Used with: Slimline SL100 and SL150 external grille box m replacement grilles permit air to flow • Adjustable length 215-380mm • Used with: Slimline SL100 and SL150 o

into the room with the door shut • Wall hole size D • Slimline design SL100 117mm * Backdraught shutter must be removed r

• Consists of two grilles and fixings i SL150 157mm • Window hole size

• Minimum door thickness 35mm a

SL100 100mm l • Dimensions: w454 x h90mm overall

SL150 150mm e w435 x h77mm hole p X www.xpelair.co.uk 59

Home systems

It is estimated that we spend There are a number of Government This DC technology is now also available 90% of our time indoors and initiatives intended to deliver savings in in the new Xplus central extract system, energy consumption of 20% over a the single room heat recovery unit and 70% of that time in our homes ten year period. For example new the EverDri range. using heating, televisions, Building Regulation Documents L lighting and computers. It’s & Part F1. To complement the whole house systems the range now also includes SystemX hardly surprising then that Xpelair sees these real environmental wholehouse ducting kits with self 45% of the UK’s carbon issues as an opportunity and accepts regulating intake and extract terminals emissions are from buildings, that the scope for cost-effective energy designed to eliminate the need for efficiency improvement in the home is system balancing on site. 27% from homes and 18% large and will continue to be created from all other buildings - by by innovation. Xcell systems are not only good for the far the nation’s single largest environment, they also reduce user Air tight buildings need controlled heating costs, maintain a ‘fresher’ home source of CO2 pollution. ventilation so the first in a our series of and lower humidity levels. This can energy efficient products is a range of provide important health benefits for With the addition of perhaps 4 million new Xpelair Xcell whole house heat new homes to the housing stock over the many allergy sufferers. recovery systems featuring the latest next 20 years, the energy needs of generation of contraflow heat recovery buildings are likely to grow faster than cells combined with long life, low energy those of other sectors. So it is to the use, DC motors. indoor environment that we need to look if we truly want to reduce our energy consumption.

60 Home Systems

NEW NEWNEW NEW

Xplus Xplus 250 & 400 Xcell Profile 150 System X EverDriXHR150 AutoFlow

Page Number 62 64 66-75 76 78 82 84 86 Type Mechanical Mechanical Mechanical System ducting Ducting system Positive Input Mechanical Passive Extract Extract Ventilation and Ventilation (PIV)Ventilation and Air-input Ventilation Ventilation Heat Recovery Heat Recovery (MEV) (MEV) (MVHR) (MVHR) Voltage Application Wholehouse Wholehouse Wholehouse Wholehouse Wholehouse Wholehouse Single room Thermostatic fresh air intake Models 4 2 15 n/a n/a 2 2 3 Max extract performance (m3/h) 493 389 810 n/a n/a 259 31 200 Duct dia (mm) 125 125 125-200 n/a n/a 100/150 148 80/100/160 AC motor nnn/a n/a LoVolt n/a DC motor n n n/a n/a n n Speeds 3 Up to 8 Up to 12 n/a n/a 4 2 n/a Carbonlite nn nn/a n/a nn n

All Xpelair ventilation products are designed to meet the good practice standard for energy efficient ventilation in dwellings. Xplus 340 and Xcell 270 are SAP Appendix Q listed. Both achieving Energy Saving Trust “Best Practice” performance levels as set out in GPG 268 Guide For Specifiers (2006 edition). The code for Sustainable Homes code level three is broadly similar to BRE’s Eco Homes very good level and the EST ‘Best Practice’ standard for energy efficiency. Code level 3 achieves a 25% minimum percentage reduction in dwelling emission rate over target emission rate calculated using SAP 2005. s m e t s y s e m o

www.xpelair.co.uk 61 H Xpelair Xplus Multipoint ventilation units and UltraDC MEV models

Xplus 275

Xplus 340 DC

SAP Appendix Q listed to Best Practice Criteria Xplus 340 DC

Key features The Range

Type: Continuous mechanical Higher density building requires new The Xplus range is a high pressure, extract unit (MEV) methods of ventilation. Apartments for quiet, speed controllable system example can often have only one designed for continuous 24/7 running Application: Wholehouse system external wall face, requiring ductwork ensuring that wet rooms are properly to reach some rooms. Having one ventilated to minimise the migration of Control options: 3 speed / 9 speed RF ventilation outlet is not only preferred high humidity to other rooms. aesthetically by architects it means Used in conjunction with Xflex flexible less builder’s work and minimises Legislation: Building Regulations ducting, Profile 29 flat ducting and noise breakout. Part F1, Xplus 340 DC RegulAir ventilation terminals, the is SAP Appendix Q Suitable for domestic dwellings with a system can be concealed above listed total internal volume up to 450m3. ceilings and in stud walls. Also suitable for a wide range of All units are speed controllable by commercial applications where Spigot diameter: 125mm means of a three speed hard wired multiple extract points can be switch. Xplus 340 DC is also available served by a single fan, for example with RF transmitter. toilet cubicles. The Xplus 340 is recognised by BRE The Xpelair Xplus range is the ideal for inclusion in SAP Appendix Q. Refer solution for multipoint extract to www.sap-appendixq.org.uk for full applications. Available in AC and now details of how improved SAP ratings with UltraDC motors Xplus is easily can be obtained. installed in houses and flats.

Select the right product for your application

Xplus 275 Xplus 340 Xplus 340 DC Xplus 340 DCRF

Reference number 91260AW 91261AW 91262AW 91263AW ac motor nn UltraDC motor nn Radio frequency controls n Speeds 3 3 9 options 9 options Extract Performance (FID, m3/h) high 385 474 450 493 med 208 354 350 273 low 139 148 150 148 Low sound pressure level (dB(A)@3m) high 47 54 54 54 Power (W) high 123 88 64 64 med 104 45 13 13 low 34 25 4 4 No. of intake spigots 3 3 4 4 Spigot diameter (mm) 125 125 125 125 Colour black white white white Weight (kg) 4.7 6.0 6.0 6.0 Guarantee (years, UK) 3 3 5 5

62 Models

Xplus 275 Xplus 340 Xplus 340 DCRF Ref. 91260AW Ref. 91261AW Ref. 91263AW • Multi-speed central extract unit • Higher performance three speed central • Includes Wireless control system • Three 125mm diameter intake spigot extract unit • Three speed wireless control unit (100 connections and a 125mm diameter outlet • Three 125mm diameter intake spigot meter range) consisting of wall mounted • Manufactured in high impact ABS connections and a 125mm diameter outlet transmitter powered by CR2430 battery and • External rotor motor / impeller • Manufactured in high impact polypropylene mains receiver fitted into the fan unit • Moulded high performance scroll • External rotor motor/impeller • Stylish slim wall switch with led • Integral fixing points • Moulded high performance scroll • Optional 9 speeds from which 3 speeds • Suitable for temperatures up to 40ºC • Integral fixing points with key hole slots can be selected • Terminal box for electrical connection • Suitable for temperatures up to 40ºC • 10mins manual timer option on speed • Black finish • Fitted with 1 meter of five core flex setting three • White finish • 30mins manual timer option on speed Three Speed Controller setting three Ref. 91457AA Xplus 340 DC • Range 100m LOS Ref. 91262AW • 3 speed control switch suitable for Xplus 275 • As Xplus 340 and 340 models • Incorporates UltraDC long life motor s Typical Specifications on page 166. l

RF Controller e Wiring Diagrams on page 183.

Ref. 91471AA d o

Performance m V

Xplus 275 Xplus 340 E M C D a r t l U d n a s t i n u Xplus 340 DCRF / Xplus 340 DC n o i t a l i t n e v t n i o p i t l u M

Dimensions (mm) |

Xplus 275 Xplus 340 s 107

205 u l p X r i a l e p X 63 Xpelair Xplus250 & 400 DC 8CV Continuous extract MEV unit with UltraDC technology NEW NEW

Xplus UltraDC

SAP Appendix Q listed to Best Practice Criteria Xplus250 DC 8CV

Key features The Range

Type: UltraDC extract MEV Two NEW Xpelair Xplus Multispeed Xpelair Y pieces can be used for further units. Two models, models with Self-commissioning UltraDC branch ducts. 125mm RegulAir ceiling choice of 8 extract technology. Energy efficient and spigots with RegulAir factory set extract performances to offer trickle and boost long lasting. grilles ensure the correct extract rate from bathrooms and toilets without Xpelair Xplus UltraDC is designed with system balancing. A louvred grille with Application: Multipoint extract unit installer selectable settings to satisfy for continuous extract filtered inlet is used in the kitchen. ventilation from Part F1 installed performances for kitchen, utility room, continuous ventilation in domestic The built-in BOOST option allows the bathrooms and toilet dwellings. The trickle speed is installer to select advanced sensors: selectable at installation, based on the active response humidity control, Control options: Boost operation from sum of the continuous extract rate adjustable overrun timer, passive additional external requirements from table 1.1a of Part F1. infrared sensor or Air Quality Sensor to switch or Xpelair active provide BOOST override. response sensors Xplus offers self-Commissioning centrifugal performance with an Xplus can be surface mounted at any Legislation: Conforms to Building Regulations Part F1 and UltraDC motor. The installer selects the angle in a cupboard or loft. performance required - Xplus selects Scottish Building Xpelair UltraDC motors reduce energy Regulations. the speed necessary to meet the consumption and last longer than Continuous mechanical performance based on the system conventional AC motors. For this extract ventilation resistance. This ensures a constant (MEV). Xplus 250 DC reason Xpelair offers a 5 year UK extract performance and lower energy 8CV is SAP Appendix Q only guarantee. listed use than AC equivalents. Three 125mm input spigots are provided for connection to Xpelair Xflex ducting. Select the right product for your application

Xplus250 DC 8CV Xplus400 DC 8CV Reference number. 92290AW 92100AW Ultra DC Longlife motor Yes Yes Self-Commissioning Yes Yes Selectable ‘installed’ performances / Watts /dB(A)@3m l/s W* dB(A) l/s W* dB(A) 1 13 3.5 26.0 57 19.1 47.8 2 22 4.2 31.2 66 26.3 50.5 3 26 5.0 32.7 68 28.0 50.7 4 28 5.5 36.0 71 30.8 50.6 5 43 9.5 40.2 84 49.1 50.7 6 43 11.3 43.1 91 60.3 50.8 7 48 12.2 45.2 95 65.6 50.9 8 64 24.2 49.6 108 96.5 50.9 Boost override speed Increases performance by one speed. Outlet spigot Ø Ø125mm Ø125mm Inlet spigots 125mm 3 3 Colour black black Weight (kg) 3.9 3.9 Guarantee (years, UK) 5 5 *Measured in typical applications comprising 1m ducting of each inlet, 3m ducting and an outlet grille fitted on outlet side. 64 Models

Xplus250 DC 8CV • Centrifugal backward curved impeller • Selectable installed continuous extract Ref. 92290AW dynamically balanced to G6.3 ISO 1940 speeds to satisfy Part F1 requirements (table 1.1a) • Multipoint extract unit designed for 8 • Surface wall ceiling or loft mounting continuous trickle speeds up to 64 l/s or • Self - commissioning motor sets fan speed boost operation - one speed higher • As a Constant volume product maximum to meet performance requirement

motor input power is rated at 97W y

• Three 125mm diameter inlet spigots and one • Maintenance free external rotor motor with g 125mm diameter outlet spigot greased for life ball bearings and thermal o l Xplus400 DC 8CV overload protection. Suitable for duct air • Casing in high impact black ABS o Ref. 92100AW temperatures up to 40ºC n • Integral fixing points • Multipoint extract unit designed for 8 • Centrifugal backward curved impeller h • Energy saving long life UltraDC motor continuous trickle speeds up to 108 l/s or dynamically balanced to G6.3 ISO 1940 c e

boost operation - one speed higher t • Selectable installed continuous extract • Surface wall ceiling or loft mounting

speeds to satisfy Part F1 requirements • Three 125mm diameter inlet spigots and one • As a Constant volume product maximum C (table 1.1a) 125mm diameter outlet spigot

motor input power is rated at 140W D

• Self-commissioning motor sets fan speed to • Casing in high impact black ABS a r

meet performance requirement t • Integral fixing points l

• Maintenance free external rotor motor with U Typical Specifications on page 166. greased for life ball bearings and thermal • Energy saving long life UltraDC motor Wiring Diagrams on page 184. h overload protection. Suitable for duct air t i temperatures up to 40ºC w t

Performance Dimensions (mm) i n

Xplus400 DC u 107 205 V

650 E M 600 t

550 c a

500 r t x

a 450 e P n i 400 s e r u u 350 s (m³(m³ /h) /h) s o e

r 300 u P n c i

250 i t t a t S 200 n

150 o C 100 Speed 1 Speed 5

50 Speed 2 Speed 6 | Speed 3 Speed 7 0 Speed 4 Speed 8

0 10 20 30 40 50 60 70 80 90 100 110 V

3

Flow rate in m /h C

(m³ /h) 8

Xplus250 DC C D 0 500 0

450 4

400 & 0 a 350 P 5 n i 300 2 e r

u (m³(m³ /h) /h) s s

s 250 e u r l P

c 200 i t p a t S 150 X r

100 i Speed 1 Speed 5 a

50 Speed 2 Speed 6 l Speed 3 Speed 7 Speed 4 Speed 8 e 0 p 0 10 20 30 40 50 60 70 X Flow rate in m3/h 65 (m³/h) Xpelair Xcell 150 Low Profile Hideaway heat recovery unit MVHR NEW NEW

Xcell 150 Xcell 150V

Key features The Range

Type: Continuous mechanical Designed for the smaller dwelling the Fitted with one of the most efficient supply and extract with New Xpelair Xcell 150 is a slimline unit heat recovery cells available, the Xcell heat recovery MVHR designed for horizontal or vertical 150 has multispeed fans which can be installation where space is at a set according to the volume of the Application: Wholehouse system premium. It is ideal for recessed fitting home, and a compact antibacterial in ceilings, in a coat cupboard or in lofts condensate drain system. Control options: 2 speeds from 4 with limited space. Xcell 150R is fitted with ‘system-side’ Xcell 150V is a vertical version with all Profile 60 multi spigots for direct Legislation: Building Regulations spigots on top of the unit, making it connection to Xpelair flat ducting. Part F1 particularly suitable for installation in kitchen cupboards. Spigot diameter: 125mm dia. or Profile 60 ductwork

Xcell 150 internal Xcell 150V internal Select the right product for your application

Xcell 150 Xcell 150R Xcell 150V Reference number 91981AA 91976AA 92004AA Max house volume (m3) 300 300 300 Room side spigots circular rectangular circular House side spigot size (mm) Ø125 204 x 60 Ø125 External spigot size (mm) Ø125 204 x 60 Ø125 Efficiency (%) 92 92 92 No. speeds 4 4 4 Performance (m3/h) 4 150 150 150 3 130 130 130 2 100 100 100 1 60 60 60 Max sound pressure (dB(A)@3m) high 34 34 34 low 27 27 27 Power (W) high 146 146 146 low 67 67 67 Roof space fitment nn n Horizontal installation nn Vertical installation n Weight (kg) 25 25 25 Guarantee (years) 3 3 3

66 SPIGOTS Condensaterates:Typical=0.4 l/h, • • • Hygenicanti-bacterialcondensatetray • • Multispeedsingleinletcentrifugalfansfor • • • R X Xcell 150V Xcell 150R Xcell 150 204x60 M Dimensions (mm) P pelair Xcell150 ef. 91981AA max=0.8 l/h 6mm wireframewithEU2mediapanel Fitted with125mmspigots and outlet p A Building RegulationPart F1 with accordance required volume/dutyofthedwellingin s w volume setting c High efficiencycounterflowheatrecovery m access panel.Suitableforceilingorloft Slimline insulatedsteelcasewithsealed erformance elected atinstallationbasedonthe ell withupto92%efficiencydependingon odels rovided withtheunit hisper quietperformance.Speedsare ounting inconfinedspaces eoeyfte low/boostswitchis remotely fitted HORIZONTAL UNITS VERTICAL UNIT R X • Options: • AsXcell150 • Ref. 92004AA X Fittedwithfourflatductspigotsfor • • pelair Xcell150V pelair Xcell150R ef. 91976AA Anti-vibration padsforloftmounting s Designed forverticalinstallationwithall c As Xcell150 pigots ontopofunit onnection toProfile60duct DRAIN POSITIONS • I ncluded asstandard r t T user toselecttrickleorboostspeed. f The wallmountedsinglegangcontrolleris Controllers itted remotelyinaconvenientpositionforthe he 4availableaccordingtotheduty equirements ofthedwelling he speedsareselectedatinstallationfrom W Typical Specifications iring Diagrams o n page 184. on page167. 67

Xpelair Xcell 150 Low Profile | Hideaway heat recovery unit MVHR Xpelair Xcell 200 Low Profile Hideaway heat recovery unit NEW NEW

Key features The Range

Type: Mechanical ventilation Designed for the smaller dwelling the The Slimline unit is designed for with heat recovery New Xpelair Xcell 200 is ideal for horizontal installation where space is at recessed fitting in ceilings in a coat a premium. Application: Wholehouse system cupboard, or in lofts with limited space. An easy access cover allows top Fitted with one of the most efficient or bottom access for inspection of Control options: 2 speed from 4 heat recovery cells available, the Xcell the filters. 200 has multispeed fans which can be Legislation: Building Regulations Options include: set according to the volume of the Part F1, home, and a compact antibacterial An electric or hot water heater BRE Digest 398 (1994) condensate drain system. maintains a constant input air temperature irrespective of the Spigot diameter: 150mm or profile Xcell 200R is fitted with ‘system-side’ outside conditions. 60 ductwork Profile 60 multi spigots for direct connection to Xpelair flat ducting.

Versions with a motorised summer 100% bypass are available. These use cool summer evening air to give ‘free’ cooling when the outside air temperature is lower than indoors.

Select the right product for your application

Xcell 200 Xcell 200R Xcell 200BP Xcell 200RBP Reference number 91977AA 91978AA 91979AA 91980AA Max house volume (m3) 480 480 480 480 Room side spigots circular rectangular circular rectangular House side spigot size (mm) Ø150 204 x 60 Ø150 204 x 60 External spigot size (mm) Ø150 204 x 60 Ø150 204 x 60 Summer by-pass nn Efficiency (%) 92 92 92 92 No. speeds 4 4 4 4 Performance (m3/h) 4 240 240 240 240 3 205 205 205 205 2 150 150 150 150 1 90 90 90 90 Max static pressure (Pa) high 350 350 350 350 Max sound pressure (dB(A)@3m) high 38 38 38 38 low 30 30 30 30 Power (W) high 260 260 260 260 low 110 110 110 110 Roof space fitment n nn n Weight (kg) 40 40 40 40 Guarantee (years) 33 3 3

68 • • kitchen ceilingvent and cloakroomareserved from thebathroom and en-suite(s)upstairs.The Profile 150insulatedductisfittedtodraw air stage ofthebuildingprocess.Typically, circular The ductworkisnormallyinstalledatthe firstfix Regulations. Wiring in accordancewithappropriateBuilding and Must becarriedoutbyacompetentperson and Hygenicanti-bacterialcondensatetray • Xcellfilters • Multi-speeddoubleinletcentrifugalfansfor • • • R X M Installation andAccessories Dimensions (mm) Performance cell 200 ef. 91977AA media panel C 150mm diametercircularspigots a fitted low/boostswitchisprovidedwiththeunit w v selected atinstallationbasedontherequired whisper quietperformance.Speedsare v c High efficiencycounterflowheatrecovery mounting inconfinedspaces access panel.Suitableforceilingorloft Slimline insulatedsteelcasewithsealed olume/duty ofthedwellinginaccordance olume setting ell withupto92%efficiencydependingon nd outlet odels ith BuildingRegulationsPart F1.Aremotely ardboard framewithEU4pleated • • • Ref. 91980AA Xcell 200RBP • • Ref. 91979AA Xcell 200BP AsXcell200exceptforrectangular • Ref. 91978AA X cell 200R grille fittedinthekitchen. volume fortheroom withanunrestrictedfiltered Xpelair RegulAirinletsprovidethechosen connected tothehouseholdwastesystem. a The 90%efficientheatrecoverycellisfitted with studwork. by Profile60ductsconcealedinthefirst floor m Condensate rates:Typical=0.65 l/h, Plus builtinmotorisedsummerby-pass As Xcell200R Plus builtinmotorisedsummerby-pass As Xcell200 d r oomside spigotssuitableforProfile60 condensate trayandoutletpipewhich is ucting ax=1.3 l/h • I ncluded asstandard r t T user toselecttrickleorboostspeed. f The wallmountedsinglegangcontrolleris Controllers itted remotelyinaconvenientpositionforthe he 4availableaccordingtotheduty equirements ofthedwelling he speedsareselectedatinstallationfrom can beselectedwithbuiltinhumidistat or timers. manual switchsensor. RegulAirexhaustvalves Boost speedcanbeselectedbymeans ofa or hall. diffusers installedinthebedroomsand lounge On theinputsidesimilarductworksupply airto Wiring Diagrams T ypical Specifications on page184. o n page 167. 69

Xpelair Xcell 200 Low Profile | Hideaway heat recovery unit Xpelair Xcell 270 DC wholehouse heat recovery unit NEW NEW

SAP Appendix Q listed to Best Practice Criteria

Key features The Range

Type: Mechanical ventilation New building regulations are striving to been closed up for long periods. The with heat recovery improve energy efficiency in the home Xpelair cell is housed in an insulated and reduce CO2 emissions. Part L cabinet and integral filters are places greater emphasis on designed to make access to the cell Application: Wholehouse system airtightness in new homes to reduce unnecessary - keeping maintenance to the energy loss through uncontrolled a minimum. Xpelair UltraDC fan units Control options: 3 speeds from 12 air leakage, so the need for an not only ensure a low running cost but intelligent controlled ventilation strategy they are also much more efficient than is becoming more critical. ac motors - keeping energy Legislation: Building Regulations usage down. Part F1, SAP Appendix Q, Wholehouse ventilation with heat recovery, is often referred to as MVHR. A choice of ten preset performance Energy Saving Trust It provides a constant background flow programmes enables flexible control Best Practice of fresh tempered air to the living over air quality and when combined with spaces of a ‘tight home’ whilst a manual switch or automatic sensor, Spigot diameter: 150mm extracting condensation, smells, the ventilation rate can be increased tobacco smoke and volatile organic temporarily to reduce humidity - perfect compounds via kitchens, bathrooms, for bath and shower rooms. utility rooms and toilets. The resultant lower humidity deprives the house Fitted with a fan failsafe interlink, if one dustmite the conditions in which to fan is stopped, the other will breed, thus contributing to a healthier automatically switch off - particularly environment. The Xpelair Xcell 270 is important in homes with open fires or one of a new breed of high efficiency unvented . Housed in a stylish MVHR units designed to save energy cabinet, the Xcell 270 can be and function reliably with extremely low unobtrusively mounted in an airing running costs. It maintains a cosy cupboard, on a kitchen wall or within a roof space. Xcell 270 internal filters indoor environment during the colder months and provides an ‘aired’ Select the right product for your application feeling even when the building has

Xcell270 Xcell270BP Reference number 91264AW 91265AW Max house volume (m3) 540 540 Summer bypass n UltraDC motor nn Efficiency (%) 90 90 Speeds selected during installation 3 3 Typical Performance (m3h) high 290 290 med 175 175 low 110 110 Max static pressure (Pa) high 300 300 Max sound pressure (dB(A)@1m) high 47.7 47.7 medium 39.7 39.7 low 32.2 32.2 Power (W) high 180 180 low 40 40 Wall mounting nn Roof space fitment n n Spigot diameter (mm) 150 150 Colour beige beige Weight (kg) 31 31 Guarantee (years, UK) 5 5 70 Models Controllers

Xcell 270 Whole House Mechanical • Motors are UltraDC, maintenance Three speed selector switch Ventilation and Heat Recovery (MVHR) unit free with sealed for life bearings Ref. 91266AW Ref. 91264AW • The integrated electronic control system • Three speed selector switch for low • Wall hanging bracket provided ensures equal constant outputs from both (night-time), medium (daytime) and • Steel powder coated cabinet sides of the ducted resistances of the unit • Beige finish • XFFI system automatically switches both high (boost setting) • High density foam insulated cabinet fans off if one fan fails to rotate • Dimensions w81 x h152 x d62mm lining/scroll construction with built in double • Complete with pre-wired connection cable sided condensate tray with choice of drain positions • Polymeric, robotically assembled heat Xcell 270BP with Summer Bypass recovery cell with bonded seals to eliminate Ref. 91265AW cross air leakage • All the features of Xcell 270 plus a built in • ContraFlow cell design providing heat summer by pass which diverts the incoming recovery efficiently up to 95% (Independent air directly into the dwelling without passing TZWL laboratory tests) through the heat exchange cell • Two stage 1 G4 filters, which are • During hot periods this ensures that removable for easy cleaning comparatively cooler incoming fresh air is • Hinged access door for access to the cell not further heated by warmer air exhausted and filters from the dwelling • 3 speeds from 12 available (via on board • This is particularly useful on summer dip switches to suit dwelling volume) or low evening when the outside temperature falls Typical Specifications on page 167. faster than that inside with switched higher speed. Factory set at Wiring Diagrams on page 185. the three most popular outlet settings

Performance

95% average efficiency Energy efficiency is achieved using the Xcell 95% efficient ContraFlow heat t

exchange cell which transfers heat from i

the extracted air and preheats the n

incoming flow ensuring a fresher, drier, u tempered atmosphere. y r e v o c e r t a

Dimensions (mm) e h e s u

A - Exhaust air (into unit) o h e

B - Fresh air (into unit) l

C - Supply air (from unit) o h

D - Exhaust air (from unit) w C D

Installation and Accessories |

Installation must be carried out by a is connected to the household waste system. 0 competent person and in accordance with Xpelair RegulAir inlets provide the chosen 7 appropriate Building and Wiring Regulations. volume for the room with an unrestricted 2

filtered grille fitted in the kitchen. l

The ductwork is normally installed at the first l

fix stage of the building process. Typically, On the input side similar ductwork supply air e circular Profile 150 insulated duct is fitted to to diffusers installed in the bedrooms and c draw air from the bathroom and en-suite(s) lounge or hall. upstairs.The kitchen ceiling vent and X Boost speed can be selected by means of a cloakroom are served by Profile 60 ducts r concealed in the first floor studwork. manual switch sensor. RegulAir exhaust valves i

can be selected with built in humidistat or a

The 90% efficient heat recovery cell is fitted timers. l with a condensate tray and outlet pipe which e

Schematic diagram of a p

typical wholehouse MVHR installation X 71 Xpelair Xcell 300 & 400 DC wholehouse heat recovery units

Key features The Range

Type: Mechanical ventilation Meeting improved energy efficiency At the heart of the unit is a 90% with heat recovery requirements for new homes combines efficient heat recovery cell which efficient heating, insulation, better air transfers the heat from the outgoing Application: Wholehouse system tightness and a controlled ventilation exhaust airflow to the incoming fresh strategy. An integrated, new generation, air whilst keeping the two flows Control options: 3 speed high efficiency wholehouse heat separated. As the temperature of the recovery system is by far the most outgoing air drops, it reaches dew Legislation: Building Regulations efficient ventilation solution for new point and gives up condensate. The Part F1 ‘tight’ buildings. warming process to the incoming air reduces it’s RH ensuring a fresh, A 90% efficient wholehouse heat Spigot diameter: 150mm (Xcell 300) condensation free indoor environment. recovery unit for larger properties. 180mm (Xcell 400) The unit features UltraDC motors The Xpelair Xcell 300 and 400 are designed for continuous operation and ideal for larger properties in order to exceptionally low running costs. The meet Part F1 requirements. unit design allows the outlet spigots to As the extract points are in the ‘wet be set vertically or horizontally to suit rooms’ – bathrooms, en-suites, site conditions. The unit is fitted with cloakroom and kitchen, the air change two cell pre-filters which are user rates in these individual rooms will be accessible from the outside and substantially higher. without having to isolate the unit.

Easy accessReplacement Spigots can be filters repositioned Select the right product for your application

Xcell 300 Xcell 300BP Xcell 400 Xcell 400BP Reference number 91267AW 91268AW 91269AW 91270AW Max house volume (m3) 600 600 800 800 Summer bypass nn UltraDC motor nnnn Efficiency (%) 90 90 90 90 Speeds selected during installation 3 3 3 3 Typical performance (m3h) high 300 300 400 400 med 200 200 200 200 low 100 100 100 100 Max static pressure (Pa) high 200 200 150 150 Max sound pressure (dB(A)@3m) high 45 45 51 51 Power (W) high 185 185 241 241 low 47 47 31 31 Roof space fitment nnnn Spigot diameter (mm) 150 150 180 180 Colour white white white white Weight (kg) 32 32 32 32 Guarantee (years, UK) 5 5 5 5

72 Models Controllers

Xcell 300 Xcell 400 Three Speed Controller Ref. 91267AW Ref. 91269AW Ref. 91457AA 3 • 300m /h MVHR Unit at 200Pa • Features over the Xcell 300 • 3 speed selector switch for low (night-time), 3 • 90% efficient cell • 400m /h MVHR unit at 150Pa medium (daytime) and high (boost setting) • Corrosion resistant aluminium construction • 180mm spigots accepts Xflex TFD insulted • Automatic defrost protection • Longlife low noise backward curved DC Test data motor/impeller sets • Efficiency independently tested to NEN • Integral condensate drain and pipe 5138 by TZWL. Efficiency 91% with an • Vertical and horizontal option separately energy usage of 47W at all spigots • 150mm spigots accept Xflex TFD insulated Summer bypass Xcell 300BP duct or Profile 150 duct Ref. 91268AW • Neon function indicator Summer bypass Xcell 400BP • Two user accessible G3 cell pre filters Ref. 91270AW that are washable • Features over the Xcell 300/400 • Polypropylene casing, fire retardant to • Units with factory fitted summer bypass are available to special order. Includes class B1/B2 s t • Cold bridging free automatic control which opens bypass i • Internal acoustic insulation when the outside temperature is over 15ºC Typical Specifications on page 167. n • Finished in RAL 9002 White and the inside temperature is over 20ºC Wiring Diagrams on page 185. u

• Fitted with flying lead y r e

Performance v o

Electrical characteristics Xcell 300 c

Volume Pst(Pa) Amps Watts e 100 100 0.3 47 r 150 125 0.4 65 t a 200 150 0.6 101 e

250 250 1.1 175 h 300 200 1.1 185 e s u

Electrical characteristics Xcell 400 o Volume Pst(Pa) Amps Watts h e

100 45 0.3 31 l

170 50 0.3 49 o

270 90 0.7 103 h

300 110 0.8 133 w 400 150 1.5 241 C

Dimensions (mm) D

Xcell 300/400 | e f A - Exhaust air from house i L

B - Fresh air from outside g

C - Supply air to dwelling n o D - Exhaust air to outside L 0 0 4

Installation and Accessories & 0 Installation must be carried out by a is connected to the household waste system. 0 competent person and in accordance with Xpelair RegulAir inlets provide the chosen appropriate Building and Wiring Regulations. volume for the room with an unrestricted 3 filtered grille fitted in the kitchen. l The ductwork is normally installed at the first fix l stage of the building process. Typically, circular On the input side similar ductwork supply air e

Profile 150 insulated duct is fitted to draw air to diffusers installed in the bedrooms, lounge c

from the bathroom and en-suite(s) upstairs. and living room. X The kitchen ceiling vent and cloakroom are Boost speed can be selected by means of a r served by Profile 60 ducts concealed in the first i manual switch sensor. RegulAir exhaust valves floor studwork. a

can be selected with built in humidistat l

The 90% efficient heat recovery cell is fitted or timers. e with a condensate tray and outlet pipe which Schematic diagram of a p typical wholehouse MVHR installation 73 X Xpelair Xcell 600 Low Profile Hideaway heat recovery unit NEW NEW

Key features The Range

Type: Mechanical ventilation Designed for the larger property, the The assembly is housed in a with heat recovery New Xpelair Xcell 600 provides high commercial quality case lined with non performance and excellent heat hygroscopic thermal/acoustic insulation Application: Wholehouse system recovery efficiency. complying with London Borough and CAA airport authority flammability and Xcell 600 is Xpelair’s largest Control options: 2 speed from toxicity requirements. wholehouse heat recovery unit, suitable 6 available for large domestic applications. Xcell 600BP has a built-in motorised Also suitable for commercial installation. summer 100% bypass. This uses cool Legislation: Building Regulations Xcell 600 features multi-speed fans summer evening air to give ‘free’ Part F1 chosen for their quiet operation an cooling when the outside air proven reliability. The heat recovery temperature is lower than indoors. Spigot diameter: 200mm cell is a high efficiency design having A remotely positioned speed selector is a typical energy recovery rate of 70%. provided with the unit. The unit is fitted with two heavy duty filters, and an anti-bacterial stainless steel outlet on condensate tray.

Select the right product for your application

Xcell 600 Xcell 600BP

Reference number 92002AA 92003AA Max house volume (m3) 1620 1620 Room side spigots circular circular House side spigot size (mm) Ø200 Ø200 External spigot size (mm) Ø200 Ø200 Summer by-pass nn Efficiency (%) 70 70 No. speeds 6 6 Performance (m3/h) 6 522 522 5 485 485 4 446 446 3 399 399 2 335 335 1 223 223 Max static pressure (Pa) high 352 352 Max sound pressure (dB(A)@3m) high 34 34 low 28 28 Power (W) high 339 339 low 90 90 Roof space fitment n n Weight (kg) 42 42 Guarantee (years) 33

74 Models Controllers

Xcell 600 • Condensate rates: Typical=1.2 l/h, Included as standard Ref. 92002AA max=2.4 l/h • The wall mounted single gang controller is • Slimline insulated steel case with sealed fitted remotely in a convenient position for the access panel. Suitable for ceiling or Xcell 600BP user to select trickle or boost speed. The loft mounting Ref. 92003AA • High efficiency crossflow heat recovery • As Xcell 600 speeds are selected at installation according cell with up to 70% efficiency depending on • Plus built in motorised summer by-pass to the duty requirements of the dwelling volume setting • Multispeed double inlet centrifugal fans for whisper quiet performance. Speeds are selected at installation based on the required volume/duty of the dwelling in accordance with Building Regulations Part F1. A remotely fitted low/boost switch is provided with the unit • Xcell filters • Hygenic anti-bacterial condensate tray and outlet • 200mm diameter circular spigots Typical Specifications on page 168. • Cardboard frame with EU 4 pleated Wiring Diagrams on page 185. media panel

Performance t i n u y r e

Speed 1 Speed 4 v Speed 2 Speed 5 o Speed 3 Speed 6 c e r t a e h y a w a

Dimensions (mm) e d i H | e l i f o r P w o L

Installation and Accessories 0 0

Must be carried out by a competent person and by Profile 60 ducts concealed in the first floor On the input side similar ductwork supply air to 6 in accordance with appropriate Building and studwork. diffusers installed in the bedrooms and lounge l Wiring Regulations. or hall. l

The 70% efficient heat recovery cell is fitted with e

The ductwork is normally installed at the first fix a condensate tray and outlet pipe which is Boost speed can be selected by means of a c stage of the building process. Typically, circular connected to the household waste system. manual switch sensor. RegulAir exhaust valves X Profile 150 insulated duct is fitted to draw air Xpelair RegulAir inlets provide the chosen can be selected with built in humidistat or timers. from the bathroom and en-suite(s) upstairs.The volume for the room with an unrestricted filtered r i kitchen ceiling vent and cloakroom are served grille fitted in the kitchen. a l e p

75 X Xpelair Profile 150 Heat recovery duct systems

Key features The Range

Type: Ducting system An efficient wholehouse heat recovery Appropriate lengths are cut using a system is only as good as the duct cross-cut saw or knife, and using the Application: Mechanical ventilation work that serves it. Reclaimed warmth collars, pushed together to build a with heat recovery can be lost before the air reaches the system that is well insulated and very living spaces through poorly insulated robust. Duct Diameter: 150mm ductwork. Where the system is connected to a Xpelair Profile 150 ideally terminal spigot or where periodic compliments the Xpelair Xcell range of inspection is necessary, SnapClamp Mechanical Ventilation with Heat collars engage tightly or release Recovery (MVHR) units. Designed for completely in seconds allowing fast quick, easy and mess free installation fitting and release as necessary. in domestic and commercial A range of matching cowled applications. Suitable for use in terminations is available. unheated spaces.

The thick but flexible foam system is lightweight, fire retardant and slim in profile. Straight ducts are supplied in 2.5m lengths and a full range of collar fit bends are available.

Fast and easy fitting

76 Models

Profile 150 System

• Lightweight insulated ducting system in convenient 2.5m lengths with little wastage • Material: vapour resistant EPE. Self 90º Bend extinguishing Class BI, DIN4102 Ref. 91273AA • Density: 50kg/m3 • Heat transfer coefficient 0,040 W/m2 at Y Piece Splitters 0ºC in accordance with DIN 52613 100 x 100 x 150mm Ref. 91282AA • Temperature range -40 to +100ºC 125 x 125 x 150mm Ref. 91284AA • Attenuates sound 150 x 150 x 150mm Ref. 91285AA • Ductwork lengths are sufficiently flexible 150 x 150 x 200mm Ref. 91286AA to get through awkward openings • Full range of bends available 45º Bend • Colour anthracite Ref. 91274AA • See also: two way splitters and roof terminations 30º Bend Ref. 91275AA Profile 150 Components

15º Bend Ref. 91276AA Roof Cowl Ref. 91277AA Straight Duct • Outlet cowl complete with flashing Ref. 91272AA • For roof pitch 25-45º • Length 2.5m • Insulated, self extinguishing EPS • i/d 150mm • Colour: black • o/d 180mm Pushfit Collar • 160mm diameter Ref. 91279AA (135mm not including foam lining) • Simple push fit • Centre stop • Collar length 10mm s m e

SnapClamp Duct Collar t

Ref. 91280AA s

Wall Cowl y • Used where Profile 150 ducts need to be Ref. 91278AA s

disconnected from an MVHR unit for t • Weather protected wall cowl

servicing or cleaning. c • Ideal for exposed locations Overcentre clamp fits firmly when engaged u • Manufactured in PVC d • Colour: brown y r

Performance e v

Schematic diagram of a o 3

Resistance at 225m /h c typical wholehouse MVHR installation

Component Resistance (Pa) e Roof cowl as outlet 1.9 r Roof cowl as intake -26.8 t a Wall cowl as intake -31.3 e Duct per metre 1.4 H 90º bend 5.3 45º bend 3.4 | 15º bend 0.4 0

Typical Specifications on page 168. 5 1 e l i f o r P r i a l e p

77 X Xpelair SystemX Wholehouse heat recovery ducting kits

Photograph highlights some of the components in System X

Key features The Range

Type: Ducting system Xpelair Xcell wholehouse heat recovery The kits consist of Profile 150 and Xflex units feature over 90% heat transfer TFD components for ducting in Application: Mechanical ventilation efficiencies and low running cost uninsulated cold areas such as the loft, with heat recovery ‘LongLife’ dc motors. To ensure that as Profile 60 components for vertical risers much of this valuable heat energy gain in stud walls and other vertical voids, is delivered back to the living areas, and splitters and RegulAir intake and Xpelair has developed two SystemX outlet terminations for wet rooms and kits which contain all the main living areas. ductwork components needed for a Site conditions will inevitably mean that standard three or four bedroom two a few components more or less will be level new home. Kit 3 is suitable for a required to complete the project. typical 3 bedroom home and Kit 4 is Choose these from the accessory list. suitable for a typical 4 bedroom home. SystemX components are delivered in Not only does this simplify the a series of easy to handle master specification but the kits offer cartons with first fix items separate substantial savings over the cost of the from the second fit fixing and grilles. individual components. Because of the grease content, it is The systems are based on a low recommended that kitchen canopies pressure drop design, aiming to keep are not connected to the system. the air paths as large as possible and Schematic diagram of a Instead, use a separate extract point at typical wholehouse MVHR installation providing the main resistance at the ceiling level. inlets and outlets.

System X Kits

Xpelair SystemX Kit 3 3x 150x125x125 Y splitter Roof cowl Ref. 91293AA 2x 125x125x125 Y splitter Ref. 91277AA Layout assumptions: 1x 10m Xflex TFD125 • Profile 150 roof cowl 26x Worm drive clip • 2 off required to complete installation • Xcell unit in the airing cupboard on first floor 13x Profile 60 flat duct • Exhaust from family bathroom and one en- 6x Profile 60 plenum box suite on first floor, kitchen general vent and 9x Profile 60 coupling Wall termination set cloak room on ground floor 3x Profile 60 vertical 90o bend • Intake to three bedrooms on first floor and hall Ref. 91455AA 1x Profile 60 T piece Required to complete installation: or lounge on ground floor 1x Profile 60 adjustable horizontal bend • 2 external terminations are required but not 2x 150mm Wall duct WD 26x Profile 60 mounting bracket 2x Wall grille included. Use either roof cowl or wall 11x RegulAir ceiling spigot termination set 2x Profile 150 45º bend 2x 2.5m Profile 150 straight duct Comprises: 2x Pushfit collar First fix Second fix 5x 2.5m Profile 150 straight duct 2x Kitchen / utility extract grille 2x Profile 150 90o bend 4x RegulAir XEI 125 input grille 2x Pushfit collar 1x RegulAir XEP 6-12 4x SnapClamp collar 2x RegulAir XEH 8-16 1x 150x150x150 Y splitter 3x RegulAir XEV 8 valve

78 Xpelair SystemX Kit 4 4x SnapClamp collar 6x RegulAir XEI 125 input grille Ref. 91294AA 3x 150x150x150 Y splitter 1x RegulAir XEP 8-16 Layout assumptions: 5x 150x125x125 Y splitter 3x RegulAir XEH 8-16 • Xcell unit in the airing cupboard on first floor 3x 125x125x125 Y splitter 5x RegulAir XEV 8 valve • Exhaust from family bathroom and two en- 1x 10m Xflex TFD125 suites on first floor, kitchen general vent and 38x Worm drive clip Roof cowl cloak room on ground floor 17x Profile 60 flat duct Ref. 91277AA • Intake to four bedrooms on first floor and hall 9x Profile 60 plenum box • Profile 150 roof cowl and lounge on ground floor 12x Profile 60 coupling • 2 off required to complete installation o • 2 external terminations are required but not 4x Profile 60 vertical 90 bend Wall termination set included. Use either roof cowl or wall 1x Profile 60 T piece Ref. 91455AA termination set 1x Profile 60 adjustable horizontal bend Required to complete installation: 34x Profile 60 mounting bracket 2x 150mm wall duct WD Comprises: 12x RegulAir ceiling spigot First fix 2x Wall grille 8x 2.5m Profile 150 straight duct Second fix 2x Profile 150 45º bend 2x Profile 150 90o bend 1x Kitchen / utility extract grille 2x 2.5m Profile 150 straight duct 2x Pushfit collar 1x RegulAir XEP 6-12 2x Pushfit collar

Extract and Input Grilles

Extract Grilles Input Grilles For use in en-suites, bathrooms, kitchens and For use in bedrooms, hall and living rooms etc utility rooms. s

RegulAir XEP 8-16 bathroom/utility t i RegulAir XEI 125 input grille

Ref: 91444AA k • Preset volume regulator. 8l/s trickle Ref: 91451AA

ventilation • Hinged diffuser 125 with a distribution pattern g n

RegulAir ceiling spigot • Pullcord opens to 16l/s allowing installation in the corner of the room • i Ref: 91452AA 125mm diameter to fit into RegulAir t • A 125mm first fix spigot that fits flush to the RegulAir XEH 8-16 bathroom/utility ceiling adaptor c ceiling, allowing decoration without masking Ref: 91445AA • Also available in 100mm dia u • Self supporting - no fixings required • Preset volume regulator. 8l/s trickle d

• Complete with rubber seal ventilation RegulAir XEI 100 input grille y • Non electric humidistat opens to 16l/s Ref:91450AA r RegulAir Exhaust grilles e • Factory set to the exhaust volume requirement RegulAir XEP 6-12 sanitary accommodation v for a room. No site balancing is necessary and Ref: 91443AA o c the performance cannot be tampered with • Preset volume regulator. 6l/s trickle e

after insulation ventilation r

• Pushed into the 125mm ceiling adaptor after • Pullcord opens to 12l/s t

decorating is complete as part of the second a

fix. Additional fixings not necessary e • Complete with rubber seal h

RegulAir XEE 8-16 bathroom/utility e s Ref: 91442AA u • Preset volume regulator. 8l/s trickle o ventilation RegulAir XEV induct constant airflow valve. • Duct mounted regulator maintains a constant h

• Electric damper opens to 16l/s e return flow volume to bedrooms etc. fits l XEK Kitchen / Utility Room extract grille 125mm Profile 150 or Xflex duct o h Ref: 91454AA XEV4 4l/s Ref: 91447AA

• A 125mm frame with removable grille/filter. At W RegulAir XEV 6-12 sanitary accommodation XEV8 8l/s Ref: 91448AA least one XEK grille must be used in the Ref: 91446AA XEV12 12l/s Ref: 91449AA

system to maintain balanced extract / intake | • Preset volume regulator. 6l/s trickle ventilation Important One of the return ducts should not be fitted with a constant airflow valve to maintain

• PIR opens to 12l/s X balance extract / intake. This is normally one of the returns to the ground floor. m e t s y S r i a l e Ceiling Spigot and regulator intake p

79 X Xpelair SystemX Accessories

Spigot Plates SP Wall Ducts WD Louvred Wall Grille White • Fixes to inside of exterior wall • For bridging cavities or lining solid exterior walls Dia LGW125 125mm Ref. 91492AA • 100mm spigot diameter SP100 • 100mm duct diameter WD100 Ref. 89697AA Ref. 89543AA • 125mm spigot diameter SP125 • 125mm duct diameter WD125 Ref. 89698AA Ref. 89703AA • 150mm spigot diameter SP150 • 150mm duct diameter WD150 Ref. 89699AA Ref. 89704AA • 200mm spigot diameter SP200 • 200mm duct diameter WD200 Ref. 89700AA Ref. 89705AA • 250mm spigot diameter SP250 • 250mm duct diameter WD250 Ref. 89701AA Ref. 89706AA • 315mm spigot diameter SP315 • 315mm duct diameter WD315 Ref. 89702AA Ref. 89707AA

NEW NEW

Louvred Wall Grille Brown Circular Air Valves CAV Circular Air Valve with Dia Dia Dia LGB125 125mm Ref. 91493AA CAV100 100mm Ref. 89682AA CAV125FD 125mm Ref. 91495AA CAV125 125mm Ref. 91490AA CAV150 150mm Ref. 89683AA • Valve includes built in fire damper for use in kitchens • Valve has adjustable centre disc • Valve has adjustable centre disc and can be • For use with XID100, XID125 and used as outlet for XID125 and Xplus XID150 • Tested to BS476 Part 20 - provides 1 hour • Flexible ducting (FD) can be terminated at fire check the valve

80 Xpelair SystemX Accessories

Insulated Circular Plastic Ducts Insulated Circular T-pieces Insulated Circular Plastic 45º Bends Dia Length Dia Dia ICT125 125mm Ref. 91476AA CPD125 125mm 2m Ref. 91474AA CPE125 125mm Ref. 91480AA CPD150 150mm 2m Ref. 91475AA ICT150 150mm Ref. 91477AA

Insulated Circular Plastic 90º Bends Circular Plastic Connectors Circular Plastic Adaptors Dia Dia Dia CPB125 125mm Ref. 91478AA CPC125 125mm Ref. 91485AA CPA125/100 125-100mm Ref. 91487AA CPB150 150mm Ref. 91479AA CPC150 150mm Ref. 91486AA CPA150/125 150-125mm Ref. 91488AA CPA200/150 200-150mm Ref. 91489AA s e i r o s s e c c A X m e t s y S r i a l e p X www.xpelair.co.uk 81 Xpelair EverDri LongLife UltraDC DC positive pressure ventilation

Key features The Range

Type: Positive input The effects of the moisture created by switched on and automatically ventilation everyday living can quickly lead to the temperature regulated to ensure deterioration of the fabric of a building. continual air quality. The units are Application: Wholehouse unit Cooking, washing, showering and designed to meet Public Sector and breathing all create water vapour – up refurbishment sector requirements for to two gallons for a family of four per positive pressure ventilation. Legislation: Building Regulations day. Without a home being able to Quick and easy to install. Part F1 ‘breathe’, this moisture has nowhere to go. Mould growth on cooler surfaces Normally installed in a matter of hours, Hole diameter: 210mm like window frames and in unventilated the units can quickly provide benefits spaces such as the back of wardrobes to the entire dwelling. not only looks bad, it can be bad for your health too. UltraDC motor means that very low running costs can be achieved while The EverDri system is based on a maintaining outstanding efficiency. continuous supply of fresh, dry air into the home. This creates a slight positive The EverDri system is ideal for existing pressure which forces moisture and properties, particularly those with brick contaminant laden air out through walls without a cavity or insulation and natural leakage points in the building. with low or intermittent heating periods. The LongLife low energy DC motor contained in the system is permanently Select the right product for your application

XEDL

Reference number 90998AA Loft spacing installation n Wall mounted Ducted n Integral electric heater Supply Performance (m3/h) 5 259 4 216 3 173 2 130 186 Supply Performance (l/s) 5 72 460 3 48 2 36 1 24 Power (W) 5 17 4 13 3 10 2 7 1 4 Guarantee (years, UK) 5

82 Models Controllers Typical Specifications on page 168. Wiring Diagrams on page 185. Built-in Controls Xpelair XEDL • Once the unit has been installed to one of Ref. 90998AA the four extraction rates appropriate to the • For installation in houses volume of dwelling there is no need to • Installed in the roof space and ducted to a change any setting. The unit will neat diffuser which is fitted to the ceiling, automatically optimise performance usually over the stairwell according to temperature • The unit draws dry air from the loft space taking advantage of solar gain which tempers the air • The UltraDC motor is extremely efficient providing very low running costs. The air is filtered and gently introduced through the ceiling diffuser

Dimensions (mm) Installation

XEDL n o i t a l i t n e v e r u s s e r p e v i t i s o

Standard loft installation p *Maximum dimensions 295 x 295mm (XEDL with Diffuser) C D | Air Circulation C

XEDL - Loft unit installed in a house D a r t l U e f i L g n o L i r D r e v E r i a l e p X 83 Xpelair LoVolt XHR150 Single room heat recovery ventilator

Key features The Range

Type: Mechanical ventilation In existing buildings, single room heat The two speed unit removes moist air with heat recovery recovery ventilators can be quicker and from the room, which then passes less disruptive to fit than ducted through a heat recovery cell, giving up Application: Single room wholehouse heat recovery systems. it’s heat to the incoming air flow. As it is warmed, the RH reduces dramatically, Xpelair LoVolt XHR 150 units can be Control options: Pullcord/Humidistat providing a flow of dry air which in turn installed quickly using a standard acts as a ‘sponge’ to soak up further core drill. Legislation: Building Regulations moisture in the room. Intake is fixed at Part F1 Suitable for domestic applications in less than the extract rate to ensure a bathrooms, utility rooms, bedrooms and slight negative pressure on the room, so Hole diameter: 150mm living rooms. Also suitable for that moist air does not migrate to the commercial applications such as hotels, rest of the dwelling. offices and meeting rooms. XHR150 is more energy efficient than Xpelair LoVolt XHR150 is the energy normal fans both in terms of heating and efficient alternative to extract ventilation. fan running costs. It also complies with It is an effective remedy for damp current Building Regulations. problems associated with household condensation.

Select the right product for your application

XHR150PC XHR150HP

Reference number 90821AA 90820AA Integral pullcord nn Automatic control from remote humidistat n Maximum efficiency (%) 80 80 Speeds 2 2 Extract performance (m3/h) boost 31 31 trickle 12 12 Extract Performance (l/s) boost 9 9 trickle 3 3 Sound pressure level (dB(A)@3m) boost 41 41 trickle 21 21 Power (W) boost 46 46 trickle 9 9 Hole diameter (mm) 152 152 Wall thickness range (mm) 229-356 229-356 Guarantee (years, UK) 3 3

84 Models

LoVolt XHR150 range LoVolt XHR150PC LoVolt XHR150HP Effective solution for condensation problems Ref. 90821AA Ref. 90820AA in individual rooms • Two speed trickle and pullcord • Built in pullcord override switch for • Suitable for solid and cavity walls boost operation On / Off operation 229-356mm thick • SELV safety LoVolt motor operation with • SELV safety LoVolt motor operation with • Easy installation - a 152mm hole can be separate SELV transformer separate SELV transformer drilled in minutes using a core cutter, the • Tubular construction with integral air • Tubular construction with integral air unit is then simply slid into place and fixed intake/outlet and wall bezel intake/outlet and wall bezel into position • Aluminium heat exchange cell • Aluminium heat exchange cell • On trickle mode, the unit is whisper quiet. • Fascia with built in filters • Fascia with built in filters At boost speed it is a mere 41dB(A) • Remote adjustable set point type humidity • The tamper proof design ensures it sensor automatically switches to boost when works constantly against the effects a higher %RH is detected from of condensation showering etc... • At the heart of the unit is an efficient • Integral light sensor to prevent misuse aluminium heat recovery cell combined with operation at night LoVolt motor assembly for complete safety, especially in the splash zones of bathrooms and showers • A separate 12V SELV transformer is supplied with the unit. This is installed outside of Typical Specifications on page 169. splash zones 1 and 2 Wiring Diagrams on page 185. • At most times the unit will ’idle’ at trickle speed r o t

Dimensions (mm) a l i t n

XHR Range e v y r e v o c e r t a e h m o

Installation and Accessories o r e l

The XHR150 range comes complete with a g

universal mounting kit for installing through the wall. n i S | 0 5 1 R H X t

Wall Mounting l o

Hole diameter: 152mm V o L r i a l e p X 85 Xpelair AutoFlow Passive air-input units

Key features The Range

Type: Building refurbishment with replacement A self contained, temperature sensitive double glazing can often lead to thermostatic piston controls the Application: All rooms condensation problems if there is opening of the indoor vent disc. In inadequate ventilation. With central automatic operation the aperture Control options: Thermostatic systems, be it central extract using decreases with declining outdoor multipoint system or a positive pressure temperature and increase with rising Legislation: Building Regulations system, it is often now necessary to outdoor temperature. Part F1 provide passive ventilators in tight The unit comes complete with wall rooms. Introducing Xpelair AutoFlow, a tube and outside weather protected Hole diameter: 85mm (AutoFlow 80) simple and neat passive ventilation unit wall grille. 105mm (AutoFlow 100) designed for installation at high level 165mm (AutoFlow 160) through a wall using a core cutter. Xpelair AutoFlow is self regulating and adjusts the airflow in relation to the outside temperature.

Diagram showing how AutoFlow opens with increasing temperature

Select the right product for your application

AutoFlow 80 AutoFlow 100 AutoFlow 160

Reference number 91295AW 91296AW 91297AW Operating temperature range (ºC) -5/+10 -5/+10 -5/+10 Maximum vent opening (mm) 15 15 15 Maximum ventilation rate (m3/h) 100 100 200 Pressure drop at max flow rate (Pa) 38 36 37 Diameter (mm) 80 100 160 Hole diameter (mm) 85 105 165 Guarantee (years, UK) 2 2 2

86 Models

AutoFlow 80 AutoFlow 100 AutoFlow 160 Ref. 91295AW Ref. 91296AW Ref. 91297AW • Self regulating passive 80mm ventilator that • Self regulating passive 100mm ventilator • Self regulating passive 160mm ventilator adjusts airflow with outside temperature that adjusts airflow with outside temperature that adjusts airflow with outside temperature • Building Regulations compliant • Building Regulations compliant • Building Regulations compliant • Maintenance free temperature sensitive • Maintenance free temperature sensitive • Maintenance free temperature sensitive actuating piston actuating piston actuatingVolume (C. pistonM.F.) Volume (C.M.F.) • Range –5ºC to +10ºC • Range –5ºC to +10ºC 051015 •20 Range25 –5ºC30 to 35 +10ºC40 45 50 55 051015 20 25 30 35 40 45 50 55 • Fitted using a standard core cutter • Fitted using a standard core cutter • Fitted using a standard core cutter • ABS front face with sound attenuating • ABS front face with sound attenuating • ABS front face with sound attenuating insulation to the reverse side insulation to the reverse side insulation to the reverse side • Telescopic wall tube for walls to 270mm • Telescopic wall tube for walls to 270mm • Telescopic wall tube for walls to 270mm • Outside weather protected wall grille • Outside weather protected wall grille • Outside weather protected wall grille • Finish in white • Finish in white • Finish in white

Typical Specifications on page 169.

Performance

AutoFlow 80 Volume (C.M.F.) AutoFlow 100 051015 20 25 303540 45 50 55

AutoFlow 160 bulb operation s t i n u t u p n i - r i a e v i s Dimensions (mm) s a P |

Dimensions (mm) Model A B C D w o

AutoFlow 80 80 40 147 75 l

AutoFlow 100 95 40 147 75 F

AutoFlow 160 157 47 207 75 o t u A r i a l e p X 87

Commercial Ventilation

Why unit ventilation? occupants. Frequently, problems result possible. In staff rooms, photocopying when the occupants activities are rooms, toilets etc. usually a window or When it comes to air quality, there is different from that which the building was wall fan can be extremely effective. nowhere more important than the originally intended. workplace. At home the environment in In general office environments 4-6 air which we live is largely within our control. Central systems can, in some cases, be changes per hour is sufficient to provide At work the air we breathe and our thermal energy wasteful as they ventilate all areas circulation and remove volatile organic comfort is provided by others. Small whether they are occupied or not. Studies compounds from furnishings, cleaning wonder then that a World Health have also shown that we react better to a agents and biological contaminants. Organisation report suggests that up to varying air circulation than a carefully Unit ventilation can effectively extract 30% of new and refurbished buildings controlled consistent environment. The tobacco smoke although specific provision may be subject to excessive complaints ability to control our own ‘air space’ to suit of tempered air to the staff is relating to indoor air quality. The the activity or the number of people recommended. symptoms include headaches, eye, nose reduces the symptoms often referred to and throat irritation, dry coughs, dizziness as . and nausea, difficulty concentrating, In retail and the hospitality sector, employers fatigue and sensitivity to odours. have an additional duty of care towards Since the 1970’s as energy costs have their staff with regard to passive smoking. risen, so buildings have become more Satisfactory air quality and airtight and in many cases the amount of is not just good for employee health, it’s recirculated fresh air has been reduced in good for business too. order to improve energy efficiency. These Localised heat, smells and moisture can reduced rates have been found to be, in be effectively removed with extract fans many cases, inadequate to maintain the installed as close to the source as comfort and health of building

88 Commercial Ventilation

GX PX RX WX WXXL ChefX

Page Number 90 92 94 96 98 100 Fan Type Axial Axial Axial Axial Axial Kitchen Canopies Positioning Window / Wall Ceiling / Panel Roof Wall Wall Over hob Models 3 3 3 4 6 3 Max extract performance (m3/h) 1614 1712 1100 1715 5000 2800 Max intake performance (m3/h) 1002 1037 915 969 5000 n/a Max power (W) 85 85 87 85 245 940 Duct dia (mm) n/a 200-315 n/a n/a n/a See product

For Commercial Sensors, Switches & Accessories see pages 102 - 105 n o i t a l i t n e V l a i c r e m m o

www.xpelair.co.uk 89 C Xpelair GX6, GX9 & GX12 Commercial window fans

Key features The Range

Type: Commercial duty Tried and tested, the Xpelair GX6, GX9 Installation in single and sealed double ventilation unit and GX12 window fans have remained glazed windows (up to 25mm) is rapid a byword for commercial window fans using Xpelair’s unique metal ladder Application: Pubs, restaurants, for over forty years. The latest GX strip / screw system, ensuring a secure offices, kitchens, range is no exception – continuing that and watertight seal against the glass. factories, schools reputation for rugged reliability, whilst and shops Both the GX9 & GX12 ranges are introducing a host of refinements to reversible and now feature totally make the range safer, faster to install Control options: Extensive range of enclosed external rotor motors and easier to clean. Now supplied with optional controllers providing constant volume outputs, longer ladder strips. available even in gusty external conditions. Pre- The contoured high gloss white balanced sickle bladed impellers Legislation: Conforms to Building housing is styled to blend in cleanly eliminate ‘fan judder’ and ensure quiet Regulations Part F1 with modern décor. A shadow grey trouble free operation. Sealed for life external grille is supplied for maintenance free bearings ensure Hole diameter: 184mm (GX6 window) unobtrusive external appearance. For suitability for running at any angle. 257mm (GX9 window) 324mm (GX12 window) safety, a finger guard is integrated into Running costs are impressively low, 203mm (GX6 wall) the housing and the window grille and when not in use the silent electro- 266mm (GX9 wall) design. On GX9 & GX12 range units, a thermal shutter cassette closes silently 330mm (GX12 wall) tamper proof positive plug and socket against backdraughts. And cleaning assembly provides a means of has never been easier. The housing, isolation for service access without the shutter cassette and impeller are all safety risk of accidental disconnection. removed in seconds. Select the right product for your application

GX6 GX9 GX12 Reference number 90800AW 89994AW 90012AW Remote switch (supplied separately) nnn Selectable intake, extract or controller operation nn Speeds 1 2* 2* Extract performance (FID, m3/h) high 266 728 1614 low 618 1214 Extract performance (FID, l/s) high 74 202 448 low 172 337 Intake performance (FID, m3/h) high 456 1002 low 412 819 Intake performance (FID, l/s) high 127 278 low 114 228 Sound pressure level (dB(A)@3m) high 37 50 55 low 48 50 Max. electrical power rating (W) 30 41 85 Hole diameter (mm) 184 257 324 Hole diameter with wall liner (mm) 203 266 330 Weight (kg) 1.9 4 7.9 Guarantee (years, UK) 3 3 3 *low speed only applies if fan used with FR22/30 controller. If controller not used fan is only single (high) speed

90 Models Controllers

GX6 GX9 with sickle blade Single Fan Controller FR22/30 Ref. 90800AW Ref. 89994AW Ref. 21868AW • 6” high performance extract axial GX12 with sickle blade • For use with GX9 and GX12 ventilation unit Ref. 90012AW • On/Off control with neon indicator. Used to • Operated by remote On/Off switch • High performance intake/extract axial select between high and low speed, intake (not supplied) ventilation unit and extract • Suitable for single and sealed double • Choice of optional controllers glazing windows and panels up to 25mm • Suitable for single and sealed double Group Fan Controller EC6H • Sealed for life maintenance free bearings, glazing windows and panels up to 25mm Ref. 21854AW suitable for running at any angle. Integrated • Balanced external rotor motor and sickle • For use with GX9 and GX12 safety thermal overload protection blade impeller for quiet efficiency • On/Off control with neon indicator. • Built-in silent action electro-thermal • Sealed for life maintenance free bearings, Infinitely variable speed selection controls shutter cassette suitable for running at any angle extract and intake air flow. For use with up • Passive tricklevent facility for background • Built-in silent action electro-thermal to four fans (not mixed sizes) ventilation with fan Off shutter cassette Group Fan Controller XCC1 • Easy clean high gloss ABS housing with • Passive tricklevent facility for background Ref. 21859AW integral finger safety guard ventilation with fan Off • For use with GX9 and GX12 • Shadow grey external grille for unobtrusive • Easy clean high gloss ABS housing with • On/Off control with neon indicator external appearance integral finger safety guard • Unique metal ladderstrip / screw connection • Shadow grey external grille for unobtrusive to external grille for security and weather external appearance tight seal • Tamperproof internal connection safety • IPX4 rated motor plug and socket • Unique metal ladderstrip / screw connection to external grille for security and weather tight seal Typical Specifications on page 169. • IPX4 rated motor Wiring Diagrams on page 186. Controller Details on page 102.

Performance Dimensions (mm) s n a

GX6 GX9, GX12 f w o d n i w l a i c r e Dimensions (mm) Model A B C D E F G H J K m

GX6 226 210 119 107 109 101 184/203 32 4-35 112 m

GX9 312 294 165 147 147 147 257/266 32 4-35 117 o GX12 408 380 216 192 190 190 324/330 34 4-35 161 C

Installation and Accessories |

The GX6, GX9 & GX12 ranges come complete with a universal mounting kit for window installations. 2

GX9 unit can be used for a variety of 1 medical and photographic applications X where light protection is required by

replacing the external grille with a G Darkroom Cowl. & 9 X G

GX6 GX9/GX12 , 6 Wall Mounting Window Mounting Wall Mounting Darkroom installation X G Hole diameter: 203mm Hole diameter: 184mm (GX6) Hole diameter: 266mm (GX9) r

257mm (GX9) 330mm (GX12) i

324mm (GX12) a

Installation Accessories Installation Accessories Installation Accessories l e

Wall Kit 280mm Ref. 89370AA Wall Kit Ref. 89372AA (GX9) Darkroom Cowl DC9 Ref. 98409AK p

Wall Kit Ref. 89374AA (GX12) X 91 Xpelair PX6, PX9 & PX12 Commercial ceiling fans

Key features The Range

Type: Commercial duty Introducing a new addition to the Xpelair for ducted input systems in the ceiling and panel mount commercial range. The PX range hospitality industry. On PX9 & PX12 axial ventilation unit introduces even greater flexibility into the units a positive plug and socket design of commercial and larger assembly provides a means of isolation Application: Kitchens, restaurants, domestic ventilation systems. Based on for service access without the safety pubs, offices, schools, the proven WX range, PX fans are risk of accidental disconnection. shops and kiosks perfect for ceiling and panel applications PX9 & PX12 models feature totally in kitchens, restaurants, pubs, offices, enclosed external rotor motors Control options: Extensive range of schools, shops and kiosks. optional controllers providing constant volume outputs, available They can be installed at any angle in even in gusty external conditions. ceilings, voids and wall panels of any Pre-balanced sickle bladed impellers Legislation Conforms to Building thickness. The ceiling hugging, low eliminate’ fan judder’ and ensure quiet Regulations Part F1 profile white fascia is styled to blend into trouble free operation. Sealed for life any ceiling type, whether smooth, tiled or maintenance free bearings ensure Hole diameter: w246 x h268 (PX6) textured. For safety, a finger guard is suitability for running at any angle. w345 x h375 (PX9) integrated into the ultra slim high gloss Running costs are impressively low, w434 x h434 (PX12) ABS fascia. An integral spigot allows the and when not in use the silent attachment of flexible ducting, such as electro-thermal shutter cassette closes Duct Size: 200/250/315 XFlex. Installation in ceilings and wall silently against backdraughts. And panels is rapid thanks to the concealed cleaning has never been easier. The fixing points provided. Both the PX9 & housing, shutter cassette and impeller PX12 are reversible making them ideal are all removed in seconds. Select the right product for your application

PX6 PX9 PX12

Reference number 91300AW 91299AW 91298AW Remote switch (not supplied) nn n Extract only n Selectable intake, extract or controller operation nn Speeds 1 2* 2* Extract performance (FID, m3/h) high 246 790 1712 low 685 1290 Extract performance (FID, l/s) high 68 219 476 low 190 358 Intake performance (FID, m3/h) high 458 1037 low 433 845 Intake performance (FID, l/s) high 127 288 low 120 235 Sound pressure level (dB(A)@3m) high 39 50 54 low 47 48 Ducting size (mm) 200 250 315 Electrical power rating (W) 34 41 85 Hole diameter (w x h mm) 245 x 268 345 x 375 434 x 434 Spigot size (mm) 200 250 315 Weight (kg) 2.8 4.7 7.9 Guarantee (years, UK) 2 2 2 *low speed only applies if fan used with FR22/30 controller. If controller not used fan is only single (high) speed

92 Models Controllers

PX6 • Balanced external rotor motor and sickle Single Fan Controller FR22/30 Ref. 91300AW impeller for quiet efficiency Ref. 21868AW • High performance extract only axial flow • Sealed for life maintenance free bearings, • For use with PX9 and PX12 ventilation unit suitable for running at any angle • On/Off control with neon indicator. Used to • Operated by remote On/Off switch (not • Built in silent action electrothermal shutter select between high and low speed, intake and extract supplied) cassette • Suitable for installation at any angle in • Ultra slim high gloss ABS fascia with Group Fan Controller EC6H ceilings, voids and wall panels of any integral safety finger guard Ref. 21854AW thickness • For use with PX9 and PX12 • Totally enclosed motor • On/Off control with neon indicator. • Sealed for life maintenance free bearings, PX12 with sickle blade Infinitely variable speed selection controls suitable for running at any angle Ref. 91298AW extract and intake air flow. For use with up • Built in silent action electrothermal shutter • High performance intake / extract axial flow to four fans (not mixed sizes) cassette ventilation unit Group Fan Controller XCC1 • Ultra slim high gloss ABS fascia with • Choice of optional controllers. Ref. 21859AW integral safety finger guard • Suitable for installation at any angle in ceilings, voids and wall panels of any • For use with PX9 and PX12 thickness • On/Off control with neon indicator PX9 with sickle blade • Balanced external rotor motor and sickle Ref. 91299AW impeller for quiet efficiency • High performance intake / extract axial flow • Sealed for life maintenance free bearings, ventilation unit suitable for running at any angle • Choice of optional controllers • Built in silent action electrothermal shutter • Suitable for installation at any angle in cassette ceilings, voids and wall panels of any • Ultra slim high gloss ABS fascia with thickness integral safety finger guard

Typical Specifications on page 170. Wiring Diagrams on page 186. Controller Details on page 102. s

Performance n a PX6, PX9, PX12 f g n i l i e c l a i c r e m m o C | 2 1 X P & Dimensions (mm) 9

PX6 PX9 PX12 X P , 6 X P r i a l e p X 93 Xpelair RX6, RX9 & RX12 Commercial roof fans

Key features The Range

Type: Commercial duty roof With commercial wall space at a compression seal. For flat roofs an mount axial ventilation premium, sometimes the only way is up! optional roof mounting plate allows RX models to be fitted to dressed curbs. unit with roof cowl Xpelair RX models are a neat way of ventilating through glazed and solid Both the RX9 & RX12 are reversible. All roofs and can be used vertically in models offer a passive trickle vent Application: Pubs, restaurants, windows on exposed sites such as option for background ventilation when offices, kitchens, coastal areas and high rise buildings. the fan is off. On RX9 & RX12 units a factories, squash courts, The commercial duty roof fans are positive plug and socket assembly schools and shops particularly suitable for pubs, provides a means of isolation for restaurants, offices, kitchens, factories, service access without the safety risk of and squash courts, schools in areas accidental disconnection. Control options: Extensive range of like changing rooms, and kiln rooms RX9 & RX12 models feature totally optional controllers and a wide range of shops. enclosed external rotor motors available The contoured high gloss white providing constant volume outputs, housing is sleekly styled. For safety, a even in gusty external conditions. Pre- Legislation: Conforms to Building finger guard is integrated into the ultra balanced sickle bladed impellers Regulations Part F1 slim high gloss ABS fascia. The UV eliminate’ fan judder’ and ensure quiet stabilised roof cowl assembly is a trouble free operation. Sealed for life generous size to provide weather maintenance free bearings ensure Hole diameter: 184mm (RX6) protection at all angles. They are suitability for running at any angle. 257mm (RX9) suitable for single and sealed double Running costs are impressively low, 324mm (RX12) glazed windows and panels up to and when not in use the silent electro- 25mm. Installation in wire cast and thermal shutter cassette closes silently sealed double glazed roof lights is against backdraughts. And cleaning rapid using Xpelair’s unique metal has never been easier. The housing, ladderstrip and screw system, shutter cassette and impeller are all ensuring a secure and weather-tight removed in seconds. Select the right product for your application

RX6 RX9 RX12

Reference number 90818AW 90424AW 90425AW Remote switch (not supplied) nn n Extract only n Selectable intake, extract or controller operation n n Speeds 1 2* 2* Extract performance (FID, m3/h) high 206 511 1100 low 430 807 Extract performance (FID, l/s) high 57 142 306 low 119 224 Intake performance (FID, m3/h) high 438 915 low 384 709 Intake performance (FID, l/s) high 122 254 low 107 197 Sound pressure level (dB(A)@3m) high 39 52 56 low 49 48 Electrical power rating (W) 35 41 87 Hole diameter (Ømm) 184 257 324 Max wall thickness (mm) 25 25 25 Weight (kg) 3.8 4.5 7.9 Guarantee (years, UK) 3 3 3 *low speed only applies if fan used with FR22/30 controller. If controller not used fan is only single (high) speed

94 Models Controllers

RX6 RX9 Single Fan Controller FR22/30 Ref. 90818AW Ref. 90424AW Ref. 21868AW • High performance extract only axial flow RX12 • For use with RX9 and RX12 ventilation unit Ref. 90425AW • On/Off control with neon indicator. Used to • Operated by remote On/Off switch • High performance intake/extract axial select between high and low speed, intake (not supplied) flow ventilation unit • Suitable for single and sealed double • Balanced external rotor motor and sickle and extract glazed windows and panels up to 25mm bladed impeller for quiet efficiency Group Fan Controller EC6H • Built in electrothermal shutter cassette • Choice of optional controllers • Passive trickle vent option for background • Tamper-proof internal connection safety Ref. 21854AW ventilation with fan Off plug and socket • For use with RX9 and RX12 • Easy clean high gloss ABS housing • On/Off control with neon indicator. • Roof cowl assembly in UV stabilised Infinitely variable speed selection controls material provides weather protection at all extract and intake air flow. For use with up roof angles to four fans (not mixed sizes) • Unique metal ladderstrip/screw connection Typical Specifications on page 170. to external grille for security and Wiring Diagrams on page 186. weathertight seal Controller Details on page 102. • Supply voltage 220-240V 50Hz

Performance

RX6, RX9, RX12 Range s n a f f

Dimensions (mm) o o r RX Range l a i c r

Dimensions (mm) e Model A B C D E F G H J RX6 210 119 107 184 112 127 319 160 4/35 m

RX9 312 165 147 257 117 159 438 219 4/35 m o RX12 380 216 192 234 161 197 554 277 4/35 C | Installation and Accessories 2

Roof Mounting Plate XRP for flat roof applications 1 X R & 9 X R RX6 RX9/RX12 ,

Kerb Mounting Kerb Mounting 6 X

Hole diameter: 184mm Hole diameter: 257mm (RX9) R 324mm (RX12) r

Dimensions (mm) i Installation Accessories Installation Accessories Model W(min) X Y Z D hole a RX6 152 76 527 375 184 l Roof Mounting Plate Ref. 00370AK Roof Mounting Plate Ref. 00371AK RX9 152 76 711 559 257 e

Kerb detail see commercial Kerb detail see commercial RX12 152 76 711 559 324 p accessories on page 91 accessories on page 91 X 95 Xpelair WX6, WX9 & WX12 Commercial wall fans

Key features The Range

Type: Commercial duty Xpelair WX ventilation units – the All WX models come complete with a ventilation unit ‘classic’ face of commercial wall fans. wall mounting kit which include a Discretely slim, tough and reliable wall liner. within – a winning formula that has Application: Pubs, restaurants, Both the WX9 & WX12 are reversible served generations of pubs, offices, kitchens, and now feature totally enclosed businesses and local authorities. factories, schools external rotor motors providing and shops Stylish commercial duty unit ventilation constant volume outputs, even in gusty designed for pubs, restaurants, offices, external conditions. Pre-balanced sickle Control options: Extensive range of kitchens, factories, schools and shops. bladed impellers eliminate’ fan judder’ optional controllers Suitable for single, cavity brick and and ensure quiet trouble free operation. available current timber frame walls. Sealed for life maintenance free bearings ensure suitability for running The wall hugging, low profile white Legislation: Conforms to Building at any angle. Running costs are fascia is styled to blend in cleanly with Regulations Part F1 impressively low, and when not in use commercial surroundings. For safety, a the silent electro-thermal shutter finger guard is integrated into the Ultra Hole diameter: w245 x h268 WX6/WX6T cassette closes silently against slim high gloss ABS fascia and the w345 x h375 WX9 backdraughts. And cleaning has never exterior wall grille design. On WX9 & w434 x h434 WX12 been easier. The housing, shutter WX12 units a positive plug and socket cassette and impeller are all removed assembly provides a means of isolation in seconds. for service access without the safety risk of accidental disconnection. Select the right product for your application

WX6 WX6T WX9 WX12 Reference number 90822AW 90823AW 89996AW 90011AW Remote switch (not supplied) n n nn Integral adjustable run-on timer (2 to 20 mins) n Extract only n n Selectable intake, extract or controller operation nn Speeds 1 1 2* 2* Extract performance (FID, m3/h) high 246 246 783 1715 low 663 1162 Extract performance (FID, l/s) high 68 68 248 476 low 184 179 Intake performance (FID, m3/h) high 477 969 low 437 815 Intake performance (FID, l/s) high 133 269 low 121 226 Sound pressure level (dB(A)@3m) high 39 39 50 54 low 47 48 Electrical power rating (W) 34 34 41 85 Hole diameter (w x h mm) 245 x 268 245 x 268 345 x 375 434 x 434 Max wall thickness (mm) 292 292 508 522 Weight (kg) 2.9 2.9 4.7 8.3 Guarantee (years, UK) 3 3 3 3 *low speed only applies if fan used with FR22/30 controller. If controller not used fan is only single (high) speed

96 Models Controllers

WX6 WX9 Ref. 90822AW Ref. 89996AW Single Fan Controller FR22/30 • 6” high performance extract axial WX12 Ref. 21868AW ventilation unit Ref. 90011AW • For use with WX9 and WX12 • Suitable for single, cavity brick and current • High performance intake/extract axial • On/Off control with neon indicator. Used to timber frame walls ventilation unit select between high and low speed, intake • Sealed for life maintenance free bearings, • Choice of optional controllers and extract suitable for running at any angle. Integrated • Suitable for single, cavity brick and current safety thermal overload protection timber frame walls Group Fan Controller EC6H • Built-in silent action electrothermal • Balanced external rotor motor and sickle Ref. 21854AW shutter cassette bladed impeller for quiet efficiency • For use with WX9 and WX12 • Passive tricklevent facility for background • Sealed for life maintenance free bearings, • On/Off control with neon indicator. ventilation with fan Off suitable for running at any angle Infinitely variable speed selection controls Ultra slim high gloss ABS facia with Built-in silent action electro-thermal • • extract and intake air flow. For use with up integral finger safety guard shutter cassette • Shadow grey external grille for unobtrusive • Passive tricklevent facility for background to four fans (not mixed sizes) external appearance with built-in ventilation with fan Off Group Fan Controller XCC1 weather protection • Ultra slim high gloss ABS facia with Ref. 21859AW • IPX4 rated motor integral finger safety guard • Shadow grey external grille for unobtrusive • For use with WX9 and WX12 external appearance with built-in • On/Off control with neon indicator WX6T weather protection Ref. 90823AW • Tamperproof internal connection safety • As WX6 with overrun timer which typically plug and socket connects to a lighting circuit • IPX4 rated motor • Timer adjustable from 2-20mins run on period after light has been switched off Typical Specifications on page 171. • IPX4 rated motor Wiring Diagrams on page 186. Controller Details on page 102.

Performance

WX6/T, WX9, WX12 s n a f l l a w l a i c r e m m o

Dimensions (mm) C

WX6/T WX9 WX12 | 2 1 X W &

Installation 9 X W , 6 X W r i WX6/WX6T WX9/WX12 a l Wall Mounting Wall Mounting e p

Hole diameter: w245 x h268mm Hole size: w345 x h375mm (WX9) X w434 x h434mm (WX12) 97 Xpelair WXXL350, WXXL400 & WXXL450 High performance extract and intake wall fans

Key features The Range

Type: Commercial duty The New Xpelair WXXL range is a Security ventilation unit designed for use in larger applications Fitted with an electric shutter system where extra extract or input performance and a tough flush fitting aluminium Application: Pubs, restaurants, is required. grille complete with bird guard on the offices, kitchens, external wall face. Suitable for public areas in pubs, factories, schools schools, municipal facilities and Control and shops industry. Used in specialist applications Every fan comes complete with a built such as squash courts, swimming in control system which requires Control options: 3 speed controller pools, telephone exchanges, atriums. connection to a simple switch (also included included). Xpelair WXXL fans differ from Legislation: Conforms to Building comparable products in FOUR Ease of cleaning Regulations Part F1 significant ways: The easy clean inner grille has a ‘secret fixing’ which allows the core of Size Hole size: w400 x h400 WXXL350 the grille to be removed for cleaning Although the fan diameters are the w450 x h450 WXXL400 without the need to remove the frame. same WXXL fans require a substantially w500 x h500 WXXL450 smaller hole through the wall.

Select the right product for your application Extract wall fans Intake wall fans

WXXL350 WXXL400 WXXL450 WXXLS350 WXXLS400 WXXLS450

Reference number 91301AA 91302AA 91303AA 91383AA 91384AA 91385AA Extract wall fan n n n Intake wall fan n n n Electric shutter n n n Speeds 3 3 3333 Supplied with 3 speed control n n nnnn Max extract performance (FID, m3/h) 2700 3600 5000 Max extract performance (FID, l/s) 750 1000 1389 Max intake performance (FID, m3/h) 2700 3600 5000 Max intake performance (FID, l/s) 750 1000 1389 Sound pressure level (dB(A)@3m) 54 59 63 54 59 63 Electrical power rating (W) 130 160 245 130 160 245 Weight (kg) 12 15 17 12 15 17 Hole size (w x h mm) 400 x 400 450 x 450 500 x 500 400 x 400 450 x 450 500 x 500 Max wall thickness (mm) 375 375 375 375 375 375 Guarantee (years) 2 22 2 2 2

98 • • Fan assemblyisseparately guardedfor • Epoxycoatedaluminiuminternalwallgrille • • • G.S.M.telescopicwalllinerissuitablefor • • W WXXL400 Ref. WXXL350 Ref. 91302AA 91301AA • M Dimensions (mm) Performance XXL450 Ref. 91303AA Easy accessterminalbox switch providedforremotewallmounting slimline threepositionandOffselection Built inthreespeedcontrol.Separate w b section gravityshuttersystemishoused Electrically actuatedheavydutyaluminium a with removablecoreforeasycleaning e Balanced motorandimpellerforquiet E sealed forlifemaintenancefreebearings External rotormotorratedatIP44with 3 s olid andcavitywallsfrom275mmto fficiency 75mm dditional safety odels ehind ananodisedaluminiumexternal xtract wallfan eather louvreandbirdguard 450 400 350 Model W WXXLS400 Ref. WXXLS350 Ref. 91384AA 91983AA Builtinwashablefilteraccessiblefrom • • ExternalrotormotorratedatIP44with • • Epoxycoatedaluminiuminternalwallgrille • • • • • Dimensions (mm) 0 0 7 574 574 524 500 524 500 450 450 400 XXLS450 Ref. 91385AA I w s s G.S.M.telescopic walllinerissuitablefor a assembly isseparatelyguardedfor with removablecoreforeasycleaningfan Balanced motorandimpellerforquietefficiency w b section gravityshuttersystemishoused Electrically actuatedheavydutyaluminium Easy accessterminalbox switch providedforremotewallmounting slimline threepositionandOffselection Built inthreespeedcontrol.Separate ntake wallfan W olid andcavitywallsfrom275mmto375mm ealed forlifemaintenancefreebearings dditional safety ehind ananodisedaluminiumexternal ithin thebuilding eather louvreandbirdguard 400 H 474 X 474 I Ref. 91457AA Three SpeedController • W Telescopic wallduct Controllers XXL IntegralSpeedControlSystem e without motor‘hum’usuallyassociatedwith speed selectorprovidesthreefanperformances h A lectronic speedcontrols ousing. Theexternalslimlinesinglegang three speedtransformerislocatedinthefan Typical Specifications on page171. 99

Xpelair WXXL355, WXXL400 & WXXL450 | High performance extract and intake wall fans Xpelair ChefX Professional kitchen canopies

Tempo Mezzo

Presto

Key features The Range

Type: Commercial kitchen A range of kitchen canopies designed The three models in the range are extract canopies for small professional catering and manufactured complete with institutional applications. commercial duty filters and built in high Application: Kitchen extract pressure centrifugal fans allowing Suitable for pub food preparation and direct discharge to atmosphere or wash up areas, club kitchens, Control options: Transformer connection to ductwork. cafeterias, smaller commercial speed control kitchens, staff kitchenettes, student When specifying, as a general guide, block kitchens, and a range of the hood should protrude outwards Legislation: Conforms to Building commercial applications. approximately 200mm beyond the Regulations Part F1 working surface with the bottom of the ChefX canopies are an all in one hood 1900mm – 2000mm from the floor. solution to a range of standard commercial duty kitchen applications. Built to a professional specification. ChefX are designed for continuous heavy use and a more demanding environment. ChefX Presto and Mezzo canopies are fabricated in brush finish stainless steel complete with condensafe channel and drain.

Select the right product for your application

Tempo Presto Mezzo

Reference number 91309AA 91310AA 91311AA Air delivery (m3/h@100Pa) 400 2200 2800 Electrical power rating (W) 100 830 940 Electrical current rating (A) 0.45 3.8 4.4 Washable mesh filters n nn Width (mm) 600 1000 1000 Weight (kg) 6.5 44 43 Guarantee (years, UK) 22 2

100 Models Controllers

ChefX Tempo • Top centre outlet to accept rectangular or Five step auto transformer Ref. 91309AA circular ductwork Ref. 91369AA • Robust design for institutional applications • Centrifugal double inlet fan and scroll • Compatible with Presto and Mezzo models. such as student block kitchens and staff assembly 6 Amp transformer providing five speed rest room food preparation areas • Speed controllable motor operation. Robust ISO casing and IPX4 rated. • Brushed stainless steel housing • IPX4 rated motor • 400m3/h extraction capacity @100Pa • Max ambient temp 65oC • Washable G.S.M mesh filters • Built in lighting - 1 x 11W CFL ChefX Mezzo • Top LH outlet Ref. 91311AA • Built in isolator and speed control with • Higher duty model for cafeterias, fast food ’on’ light outlets, food preparation and wash up areas • Centrifugal fan / scroll assembly • Stainless steel housing with G.S.M support components 3 ChefX Presto • 2800m /h extraction capacity @100Pa Ref. 91310AA • Washable 25mm baffle filters • For cafeterias, fast food outlets, food • Top centre outlet to accept rectangular or preparation and wash up areas circular ductwork • Stainless steel housing with G.S.M support • Centrifugal double inlet fan and scroll components assembly Typical Specifications on page 172. • 2200m3/h extraction capacity @100Pa • Speed controllable motor. Wiring Diagrams on page 187. • Washable 25mm G.S.M mesh filters • IPX4 rated motor • Max ambient temp 65ºC Remote Sensors on page 154.

Performance

Tempo Presto Mezzo s e i p o n a c n e

Dimensions (mm) h c t Tempo Presto Mezzo i k l a n o i s s e f o r P | X f e h C r i a l e p X 101 Xpelair Commercial Sensors and Switches

Single Fan Controller FR22/30 Single Direction Group Fan Controller XCC1 Reversible Group Fan Electronic Ref. 21868AW Ref. 21859AW Controller EC6H • Sliding switches • Sliding switches and speed control knob Ref. 21854AW • On/Off • On/Off • Sliding switches and speed control knob • 2 speeds: low- high speed • Infinitely variable speed control • On/Off • Extract - intake airflow • Single direction: extract or intake • Infinitely variable speed control • Power 'on' indicator selected at installation • Extract - intake airflow • For surface or recess mounting • Power 'on' indicator • Power 'on' indicator • Supply voltage: 220 -240V 50Hz • For surface or recess mounting • For surface or recess mounting • Gloss white • Supply voltage: 220 - 240V 50Hz • Supply voltage: 220 - 240V 50Hz • Use with: GX9, GX12, WX9, WX12, PX9, • Gloss White • Gloss White PX12, RX9, RX12 • Use with: GX9, GX12, WX9, WX12, PX9, • Use with: GX9, GX12, WX9, WX12, PX9, • w210 x h86 x d41mm PX12, RX9, RX12 PX12, RX9, RX12 Note: do not mix fan size. For use with up Note: do not mix fan size. For use with up to 4 - size 12 or 6 - size 9 fans units. to 4 - size 12 or 6 - size 9 fans units. • w160 x h86 x d45mm • w160 x h68 x d45mm

Remote Humidistat XRH Passive Infrared Sensor XPIRA Time Controller DT20B Ref. 21856AW Ref. 21871AA Ref. 21850AW • Stand alone humidistat switches on when • Position to switch the fan on when body • Usually connected to the lighting circuit. RH rises to preset level and Off when movement is detected. Ideal for Fan switches On with the light. Provides it declines infrequently used public spaces continued ventilation run-on • Fan operation indicator light • Built in run on timer to avoid period after the light has been • Pullcord operated override switch nuisance tripping switched off • Surface or recess mounting • For indoor use only • User adjustable up to 20min • White finish • Use with: GX6, GX9, GX12, WX6, WX9, • Surface or recess mounting • Supply voltage 220 - 240V 50Hz WX12, PX6, PX9, PX12, RX6, RX9 & RX12 • White finish • Use with: GX6, GX9, GX12, WX6, WX9, WX12, • w86 x h86mm • Supply voltage 220-240V 50Hz PX6, PX9, PX12, RX6, RX9 & RX12 • Use with: GX6, GX9, GX12, WX6, WX9, • w160 x h86 x d41mm WX12, PX6, PX9, PX12, RX6, RX9 & RX12 • w100 x h86 x d45mm

Controller HC301 Air Quality Sensor AQS Ref. 21877AW Ref. 92097AW • On/Off switch • Provides fully automatic control • Fan only/fan and heater options • Detects contaminants such as cigarette smoke, • Variable thermostatic control body odours, toilet odours and cooking smells • Suitable for surface or recessed installation • Activates ventilation system when preset • Colour: White threshold level is exceeded • Used with WH30 and WHP30 • Can control up to six fans and accessories • w210 x h86 x d41mm • Integral timer adjustable from 3 - 30 mins • LED status indicator • Surface or recess mounting • Supply voltage 220-240V 50Hz • w160 x h86 x d41mm

102 Xpelair Commercial Accessories

GX Wall Kits WK Extendible Interlocking Wall Kits WK6 Darkroom Cowl DC9 WK6/8 200mm (GX6) Ref. 89369AA WK6/300 Ref. 90085AA Ref. 98409AK WK6/11 280mm (GX6) Ref. 89370AA WK6/450 Ref. 90086AA WK9/8 200mm (GX9) Ref. 89371AA • For use in scientific and photographic WK9/11 280mm (GX9) Ref. 89372AA • For bridging cavity wall constructions, applications WK12/8 200mm (GX12) Ref. 89373AA or lining solid double brick walls • Replaces the outer grille on GX9 and WK12/11 280mm (GX12) Ref. 89374AA • Interlocking facility to build up to GXC9 models required length • Roof, window or wall mounting • For bridging cavity walls and lining • Available in 300mm or 450mm lengths • Hole Ø257mm double brick walls • Complete with 508mm ladder strips • Colour: black • Steel wall liner • Use with: GX9, GXC9 • Length: 200mm and 280mm • w475Ø d144 x 117 • Set of 508mm ladder strips s e i r o s s e c

Distance Pieces GXDP Roof Cowls RC Roof Mounting Plates XRP c

Ref. 56708AA RC6 Ref. 89997AW (GX6, GXC6) XRP6 (RX6) Ref. 00370AK A RC9 Ref. 90048AW (GX9, GXC9) w592 x h542 x d89 Ø105

• Allows GX units to be fixed to distorted RC12 Ref. 90092AW (GX12) XRP9 (RX9) Ref. 00371AK & walls of 38mm minimum thickness w774 x h774 x d101 Ø257

• By spacing the fan unit and outer grille • For use in roof applications. XRP12 (RX12) Ref. 00371AK s

away from the wall or panel, distortion • The cowl is fitted in place of an exterior grille. w774 x h774 x d101 Ø324 e

through over tightening is prevented • Can also be used in exposed window or wall h

• Set of 6 applications subject to strong prevailing • Provides effective and secure installation c

winds in flat roof applications t • Flame retardant resin bonded fibre glass. i • Requires the installer to build a kerb onto which plate is fixed. Always use w sealant to bed in the outer cowl S

seal for weatherproof joint ,

• Colour black s r o s n e S l a i c

GX Longer Length Ladder Strips GXL Double Window Kits GXDW r

GXL20 20 pack Ref. 89382AA GXDW6 (GX6 & GXC6) Ref. 98229AA e GXL50 50 pack Ref. 89383AA GXDW9 (GX9 & GXC9) Ref. 98228AA GXDW12 (GX12) Ref. 98227AA m

• Used when installing GX fans m through walls • For hinged double windows only o • Length 508mm • For installation of GX fans into separate • Easy to cut double windows spaced between C

• GX6 & GXC6 2 strips 32mm and 102mm r • GX9 & GXC9 3 strips • Allows inner casement window to be i opened without dismantling the fan a

• GX12 4 strips l e p X www.xpelair.co.uk 103 Xpelair Commercial Accessories

Air-Replacement Grilles ARG Fire Blocks FB Protective Wall Grilles PG ARG20 w200 x h200 mm Ref. 89833AA FB20 w200 x h200 mm Ref. 89835AA PG6 (GX6, GXC6, WX6) Ref. 89375AA ARG30 w300 x h300 mm Ref. 89834AA FB30 w300 x h300 mm Ref. 89836AA PG9 (GX9, GXC9, WX9) Ref. 89376AA PG12 (GX12) Ref. 89377AA • For use with all commercial fans • For use with air replacement grille (ARG) PGW12 (WX12) Ref. 90204AA • Fitted to doors or partition walls to • Fitted between two grilles in a fire door provide adequate air replacement or compartment • For use with GX and WX fans to protect for a fan • Spec fire rated 60 mins to BS478 Part 8 the exterior grille from damage by vandals • Can be used in conjunction with FIRE • Constructed from steel mesh and finished BLOCK FB in fire doors and panels to in black expoxy powder paint prevent the breach of fire protected • Surface mounted to exterior wall using areas or compartments fixing screws and wall plugs provided • Each set comprises 2 grilles • w356 x h305 x d67mm

Flexible Ducting Xflex FD New Aluminium Flexible Ducting Xflex ALU Thermal Flexible Ducting Xflex TFD Dia Length Dia Length Dia Length FD100 100mm 3m Ref. 89663AA ALU100 100mm 10m Ref. 91435AA TFD100 100mm 5m Ref. 89847AA 6m Ref. 89669AA ALU125 125mm 10m Ref. 91436AA 10m Ref. 91459AA FD125 125mm 3m Ref. 89664AA ALU150 150mm 10m Ref. 91437AA TFD125 125mm 5m Ref. 89848AA 6m Ref. 89670AA Commercial Diameters 10m Ref. 91460AA Commercial Diameters ALU200 200mm 10m Ref. 91438AA TFD150 150mm 5m Ref. 89849AA FD150 150mm 3m Ref. 89665AA ALU250 250mm 10m Ref. 91439AA 10m Ref. 91461AA 6m Ref. 89671AA ALU315 315mm 10m Ref. 91440AA Commercial Diameters FD200 200mm 3m Ref. 89666AA ALU400 400mm 10m Ref. 91441AA TFD200 200mm 5m Ref. 89850AA 6m Ref. 89672AA 10m Ref. 91462AA FD250 250m 3m Ref. 89667AA • Tough foil construction on a high strength TFD250 250mm 5m Ref. 89851AA 6m Ref. 89673AA wire helix 10m Ref. 91463AA FD315 315mm 3m Ref. 89668AA • Over 40 minute fire rating BS 476: TFD315 315mm 5m Ref. 89852AA 6m Ref. 89674AA Part 20 (1987) 10m Ref. 91464AA

• Glass fibre fabric on a PVC coated close • Double skinned insulated aluminium pitch steel wire helix. 54 minute fire duct with high density fibreglass integrity from within as measured to BS insulation to minimise condensation 476: Part 20 - (1987) formulation • Can be interlocked and sealed with duct • 25 minute fire integrity from within as tape to form an airtight seal measured to BS 476: Part 20 - (1987) • Attached to spigots using worm drive clips • Can be interlocked and sealed with duct tape to form an airtight seal • Attached to spigots using worm drive clips

104 Xpelair Commercial Accessories

Worm Drive Clips WDC Grille Box GB Spigot Plates SP Dia Duct Dia Square Duct Dia Square WDC5 100 -125mm Ref. 89684AA GB20/100 100mm 200mm Ref. 89676AA SP100 100mm 180mm Ref. 89697AA WDC8 150 - 200mm Ref. 89685AA GB20/125 125mm 200mm Ref. 89677AA SP125 125mm 175mm Ref. 89698AA WDC13 250 - 315mm Ref. 89686AA GB20/150 150mm 200mm Ref. 89678AA SP150 150mm 200mm Ref. 89699AA GB30/200 200mm 300mm Ref. 89679AA SP200 200mm 250mm Ref. 89700AA • Steel clips for connecting flexible GB30/250 250mm 300mm Ref. 89680AA SP250 250mm 300mm Ref. 89701AA ductwork to spigots. GB45/315 315mm 450mm Ref. 89681AA SP315 315mm 365mm Ref. 89702AA • Supplied in packs of 10 GB50/315 315mm 500mm Ref. 89828AA GB60/315 315mm 600mm Ref. 90296AA • Fixes to the interior surface of wall to connect to Xflex ducting • Used in conjunction with egg-crate ceiling • Connect duct using worm drive clips grille and ceiling diffuser grille to connect • Material: plastic to ductwork • Use Xflex FD or TFD to attach to spigot and secure with worm drive dip s e i r o s s e c c A & Egg-crate Ceiling Grilles CG Ceiling Diffuser Grilles DG Air Volume Dampers AVD s Square SATIN SILVER Square SATIN SILVER Square e CG20 200mm Ref. 89675AA DG20 200mm Ref. 89816AA AVD20 200mm Ref. 89829AA h CG30 300mm Ref. 89532AA DG30 300mm Ref. 89818AA AVD30 300mm Ref. 89830AA DG45 450mm Ref. 89820AA AVD45 450mm Ref. 89831AA c CG45 450mm Ref. 89533AA t CG50 500mm Ref. 89827AA DG50 500mm Ref. 89822AA AVD50 500mm Ref. 89832AA i DG60 600mm Ref. 90292AA CG60 600mm Ref. 90295AA w • Clips directly to an eggcrate grille or Square WHITE S Square WHITE ceiling diffuser grille to adjust the volume DG20 200mm Ref. 89815AW , CG20 200mm Ref. 89823AW of air entering the room DG30 300mm Ref. 89817AW s

CG30 300mm Ref. 89824AW • Lever adjustment r DG45 450mm Ref. 89819AW

CG45 450mm Ref. 89825AW • Depth 44mm o DG50 500mm Ref. 89821AW

CG50 500mm Ref. 89826AW • Used together with Grille Box and s DG60 600mm Ref. 90603AW

Xflex ducting n

• Can be used on ceilings or internal walls • Material: Aluminium Mill finish e • For air input systems terminating at

as an air replacement grille with large S ceilings and internal walls free area • Adjustable grille vanes to set up l • Aluminium construction direction of airflow for a particular area a • Fixing screws provided (not size 600) i • Fixing screws provided (not size 600) • Use will grille boxes and Xflex ducting c

• Use with grille boxes and Xflex ducting r • Colours: Satin silver or white

• Aluminium construction e • Colours: Satin Silver or White m m o C r i a l e p X www.xpelair.co.uk 105

Heating and Air Treatment

Whether at home or work we In public places, body heat and odour Xpelair’s wide range of ventilation all try to create ‘just the right can be the overriding problem. The solutions now includes heating, cooling average heat output in a pub is about and filtration systems designed to provide atmosphere’. It affects our 250W per person. So, for example, a pub pleasant air movement that refreshes and comfort, our health and is with 80 people can be adding 20kW of combats stale air, remove airborne good for business. heat to an enclosed room. pollutants at source, and heat or cool on demand. In addition, controllers and Achieving that goal will vary by location, Solar heat gain can be a major Xpelair accessories allow you to design a time of day, the seasons and the activity. contributor to discomfort in glazed customised solution for individual It might be stale air and lack of air atriums and conservatories. applications. movement in a public house or factory, An open window may make matters worse hygiene concerns in a doctor’s waiting with the ingress of noise and fumes. room, a cold winter’s draught through a shop doorway or an uncomfortable The activity inside may limit or forbid bedroom on a hot summers night. unattenuated openings to the outside e.g. a factory process or a disco. Some points to bear in mind. At home, double-glazing and improved At work, employers are legally required to insulation provide higher levels of air ensure that during working hours tightness than ever before. This is good temperatures are reasonable and for our general comfort but often fails to comfortable. cope with seasonal extremes.

106 Heating and Air Treatment

Screen Electrostatic DigitempWH & WHP DCHPlinthHeat Heat Whispair Air Cleaners DigiPure

Page Number 108 110 112 112 114 116 118 120 Type Air Fan heater Fan heater Plinth Over door Circulation Air cleaner Air cleaner conditioner heater heater fan Application Heating and Commercial Domestic & Kitchen Hot air Destratification Air Air cooling commercial curtain purification purification Models 4 3 1 6 2 4 6 4 Max heating output (kW) 2.03 6 3 2 4.5 n/a n/a n/a Max cooling capacity (kW) 2.45 n/a n/a n/a n/a n/a n/a n/a Mounting Wall Wall Wall Cupboard Wall Ceiling Ceiling Floor, wall base ceiling

Control Options Remote Control nnnn Integral Controls nn n n n t n e m t a e r t r i A d n a g n i t a e

www.xpelair.co.uk 107 H Xpelair Digitemp Comfort and heating

Key features The Range

Type: Modular climate control Cool in summer, cosy in winter. Xpelair Digitemp is a stylish ‘slimline’ wall Digitemp offers all year climate control mounted ‘all-in-one’ solution, providing Application: Domestic, commercial for homes of all shapes and sizes. all year round comfort – cooling, and leisure Installing climate control can bring a heating and dehumidification all at the sense of comfort and style to a home, touch of a hand held remote control. Control options: Remote hand held fulfiling the expectations of modern With no outdoor condensing unit to family life. Hole diameter: 155mm install and no gas connections, the unit The self-contained Digitemp unit is is easy and quick to fit at high or low ideal for use in the bedroom and living level. Installation can be done internally spaces and studies. The quiet and with the only sign of the system on the sleek unit is installed internally without outside of the building being two the use of an unsightly outdoor discreet grilles. condensing unit – making it particularly suitable for use in apartments and multi The WA210N and WA245N models storey locations where other systems provide cooling only. Whereas the require planning permission. The WHP210N and WHP245N provide the Digitemp is even suitable for some convenience of heating and cooling in listed building applications. a single unit.

Select the right product for your application

WA210N WA245N WHP210N WHP245N

Reference Number 91173AA 91174AA 91175AA 91154AA Cooling capacity (kW) 2.1 2.45 2.1 2.45 Heating capacity (kW) 1.9 2.03 EER (Energy Efficiency Ratio) 2.66 2.66 2.23 2.23 COP (Coefficient of Performance) 2.64 2.61 Max. absorbed power rating (W) 930 1320 930 1320 Dehumidification capacity (l/h) 1.0 1.2 1.0 1.2 Energy efficiency class (cooling) A C A C Energy efficiency class (heating) C F Room air volume (m3/h) 350 390 350 390 Fan speed settings 3 3 3 3 Max. noise levels dB(A) 37 39 37 39 type R410a R410a R410a R410a Max range of infrared remote control (m) 8 8 88 Power supply (V) 230 230 230 230 Power supply (Hz) 50 50 50 50 Guarantee (years, UK) 2 2 2 2 Weight kg 58 52 52 52

108 Models Controllers

• Can operate in cooling, heating or Cooling and Dehumidification dehumidification modes to maximise comfort. Digitemp WA210N • Easy installation from within the room - 2.1kW (cooling) patented folding grille system eliminates the Ref. 91173AA need for external access • Everything needed to fit the unit is supplied Digitemp WA245N apart from a drill and Ø155mm core cutter! 2.1kW (cooling) • The electronic control system includes Ref. 91174AA infrared remote control night function and Cooling, Heating and Dehumidification automatic operation Digitemp WHP210N • Can be installed at high or low level for 2.1kW (cooling) and 1.9kW (heating) maximum flexibility and useable space Ref. 91175AA • Economic and efficient, combining low The automatic control system provides power consumption when cooling with a Digitemp WHP245N precise climate control at the press of a high efficiency heating capacity 2.45kW (cooling) and 2.03kW (heating) button. All operational modes are • Digitemp uses a three speed fan including Ref. 91154AA night mode for super-quiet operation programmable using the infrared handset • Factory sealed refrigerant system eliminates - no need to move to adjust the room the need to connect hoses temperature. • Self-diagnostic programme for all Typical Specifications on page 172. maintenance requirements Dimensions (mm)

Digitemp Range g n i t a

Installation e h d n a g n i n o i t i d n o c r High level installation Low level installation Internal appearance External appearance i a t r o f Installing Digitemp from within the room at high or low level is quick and easy. The refrigerant m system is factory sealed so installation does not o

involve opening the system or the connection of C any hoses.

Digitemp can only be positioned against an | outside wall. Where possible the unit should be

sited in the centre of the wall. p Two 155mm diameter holes are core drilled at a m sloping angle towards the outside. The diameter must not be reduced or restricted. e t i The indoor wall bracket and ducts are fitted. g The patented, folding, outside inlet and outlet i grilles are installed from within the room. D

The unit is fixed to the bracket with care taken r that it is perfectly level. i a

The unit is wired to a fused spur. l e p X 109 Xpelair WH30, WH60 & WHP30 Commercial wall heaters

WH30 WHP30

WH60

Key features The Range

Type: Wall Mounted Heaters The Xpelair WH range of wall heaters This has resulted in a range of tough, have stood the test of time to remain compact space heaters for the most Application: Commercial and market leaders. demanding environments. Industrial The WH range is perfect for use in The WH30 and WH60 models provide factories, warehouses, workshops, robust and rugged heating units, while Control options: Integral/remote canteens, and is also ideal for public the WHP30 provides comfortable, areas of shops, waiting rooms, office, reliable heating solutions for shops, garages, hospitals, large stores and offices, domestic workshops and even agricultural applications. conservatories.

Whatever the size, shape and The WH range has gained a worldwide application of a project, the WH range reputation for excellence and the range has a unit that will suit its heating continues to be built to the high requirements. Efficient, stylish, discreet standard that has won it this acclaim. and energy efficient, the WH range offers choice, flexibility and outstanding heating performance.

Select the right product for your application

WH30 WH60 WHP30

Reference number 98392AC 00147AC 89999AW Remote switch (not supplied) n n Electrical power (kW) 363 Phase 1 1 or 3 1 Air delivery (m3/h) 274 311 300 Air delivery (l/s) 76 86 83 Temperature increase (ºC) 26 45 30 Weight (kg) 5 6.5 2.9 Guarantee (years, UK) 1 1 1

110 Models Controllers

Xpelair WH30 Xpelair WHP30 HC301 Controller for WH30 and WHP30 Ref. 98392AC Ref. 89999AW Ref. 21877AW • 3kW industrial fan heater • 3kW commercial fan heater • Controller provides On/Off switching • Compact wall hung design • Fan heater complete with HC301 combined with fan only or fan and heater • Heavy duty steel casing with die cast thermostatic controller operation. Variable thermostatic control. Not aluminium guards • Compact wall hung design suitable for WH60. • Spiral wound Nichrome wire element • Flame retardant polycarbonate / glass filled • Metal wall bracket nylon casing • Multi directional positioning -180o horizontal • Spiral wound Nichrome wire element swivel and 45o vertical tilt then locked • Grey wall bracket in position • Multi directional positioning - 180o • Wall bracket cover horizontal swivel and 45o vertical tilt then • Double safety feature of thermal cut out locked in position with auto reset and one shot fusible link • Double insulated with two thermal cut outs • Single phase product • Finished in a white and grey casing • For cool air circulation facility and • Single phase product thermostatic heating control use HC301 • For cool air circulation facility and Controller (not supplied) thermostatic heating control use HC301 Controller (included)

Xpelair WH60 features over the WH30 Ref. 00147AC • 6kW industrial fan heater • Wall or ceiling mounting with multi directional positioning - 180o horizontal swivel and 45o vertical tilt then locked in position Typical Specifications on page 172. • Suitable for Single and Three phase supplies Wiring Diagrams on page 187. • Operated by remote switch (not supplied) Remote Sensors on page 102. s r e t

Dimensions (mm) a e h l WH30 WH60 WHP30 l a w l a i c r e m m o C | Installation and Accessories 0

WH30 WHP30 WH60 3 Should be sited between 2m and 2.5m from Should be sited at least 1.8m from the floor Recommended height 2.3m – 2.6m floor to P

the floor level to the centre of the unit, a level to the centre of the unit, a minimum of centre of heater H minimum of 200mm from the ceiling and 150mm from the ceiling and 300mm from 100mm from adjacent walls and other objects. adjacent walls and other objects. Not W Not recommend for rooms with a ceiling recommend for rooms with a ceiling height & height greater then 5m. greater then 5m. 0 6 H W , 0 3 H W r i a l e p X 111 Xpelair PlinthHeat & DCH3000A Plinth heaters and Commercial wall heaters

DCH

PlinthHeat

Key features The Range

Type: Unitary Heating The PlinthHeat range can provide vital Suitable for a variety of commercial warmth to a cold floor and rapidly heat applications including hallways, offices, Application: Shops, offices, kitchens a room. The unit sits neatly in the plinth pubs, restaurants, shops and hotel below a kitchen cupboard to provide rooms, the sleek wall-mounted unit fits Control options: Integral/remote an unobtrusive flow of warm air at perfectly into any busy area where floor level. reliable, comfortable heat is required. Hole diameter: w440 x h95mm Available with built-in control or for Requiring only two wall screw fixings, further convenience a thermostat and the unit is easy to fit and lightweight, switch can be wall mounted elsewhere making it ideal for rented or additional in the room. spot heating applications. The heater offers a choice of three heat outputs The units are available in three colours to and can be automatically regulated match modern décor; ice white, conker using the built in thermostatic control. brown and brushed stainless steel. For all year round comfort, the heater The wall fitted DCH 3000A fan becomes a circulation fan at the flick powered heater circulates instant of a switch. warmth to a room. From its unobtrusive position on any wall, the heater spreads heat and comfort around the room while remaining inconspicuous and quiet.

Select the right product for your application

PlinthHeat BR PlinthHeat WR PlinthHeat SR PlinthHeat B PlinthHeat W PlinthHeat S DCH3000A Reference number 91468AB 91467AW 91313AW 91466AB 91465AW 91312AW 90792AW Integral Control nnnn Remote Control nn n Requires remote control kit 87100 nn n Electrical power (kW) 2 2 2 2 2 2 3 No. of heat settings 2 2 2 2 2 2 3 Phase 1 Air delivery (m3/h) 110 110 110 110 110 110 115 Air delivery (l/s) 28 28 28 28 28 28 32 Colour brown white stainless steel brown white stainless steel Weight (kg) 2.35 2.35 2.35 2.35 2.35 2.35 4.5 Guarantee (years, UK) 1 1 1 1 1 1 1

112 Models

PlinthHeat with remote control* • Available in a choice of models with integral Xpelair DCH3000A Ref. 91467AW controls or with remote thermostatic controls Ref. 90792AW Finish: Ice white • 1kW and 2kW settings • 3kW wall mounted heater with circulation fan • Stitched ‘black heat’ element • Three heat settings - 1kW, 2kW and 3kW PlinthHeat with remote control * • Maintenance free motor with sealed for • Adjustable EnergySaver temperature sensor Ref. 91468AB life bearings control regulates heat output Finish: Conker brown • Power ‘On’ indicator lamp • Easy installation and simple operation PlinthHeat with remote control* • Automatic thermal cut out for safety Ref. 91313AW • Fits flush with standard plinths of 120mm Finish: Stainless steel and over • Crossflow blower PlinthHeat with integral control • Available in ice white, conker brown and Ref. 91465AW stainless steel finishes Finish: Ice white s

* Requires remote thermostatic control kit r

PlinthHeat with integral control e

consisting of wall mounted single stage t Ref. 91466AB variable thermostat, fused double pole a

Finish: Conker brown switch, two gang box and cable wall clamp. e

Ref. 87100 h

PlinthHeat with integral control l l Ref. 91312AW a Finish: Stainless steel Typical Specifications on page 173. w l Wiring Diagrams on page 188. a i c r

Dimensions (mm) e m PlinthHeat DCH3000A m o C & s r e t a e h h

Installation t n i l

PlinthHeat DHC3000A P Hole size: 440mm width Heater should be mounted not less than 305mm

95mm height from the floor or 610mm from a ceiling and | nearby objects.

Electrical supply 220-240V 50Hz single phase. A

The unit must be mounted on an unbroken 0

surface which completely covers the back panel. 0 0 3 H C D & t a e H h t n i l P r i a l e p X 113 Xpelair ScreenHeat Doorway hot air curtains

Key features The Range

Type: Unitary Heating The ScreenHeat range of fan powered Suitable for a range of doorway doorway heaters provides the ideal applications in commercial premises Application: Shops, offices, kitchens solution for draught exclusion on such as shops, offices, workshops and external doors. When mounted on the stores, the ScreenHeat is designed for Control: Integral/remote inside of an external door, the fast installation with two key hole-slot ScreenHeat creates a ‘hot air curtain’ brackets providing complete flexibility to prevent cold draughts entering a of adjustment from vertical to building. horizontal. Easily accessible switches allow the option to run the unit on fan In summer, the ScreenHeat can be only or at half or full heat output. switched to run only with the fan to form a barrier against incoming dust ScreenHeat units are available in a and provide a refreshing breeze. contemporary powder coated finish.

Select the right product for your application

ScreenHeat 3 ScreenHeat 4.5 Reference number 91469AW 91470AW Integral Control n n Electrical power (kW) 3 4.5 No. of heat settings 2 & fan only 2 & fan only Air delivery (m3/h) 250 250 Air delivery (l/s) 69 69 Colour white/grey white/grey Weight (kg) 5.44 5.44 Guarantee (years, UK) 1 1

114 ScreenHeat • • • R ScreenHeat 3 Heaterelementisofopencoildesign • • Ceiling Mount Installation andAccessories D Models ef. 91469AW High volumethroughput250m Two heatoutputs:1.5kW, and3kW Doorway hotaircurtain supported byceramicinsulators overload protection g Smooth running,shadedpolemotor, with imensions (mm) reased forlifebearingsandsafetythermal 3 / h Wall Mount White/greyfinish • Tangential blower • • • • • Theheaterhasaseparatethermalcut-out • v Brackets allowtheunittoberotatedfrom f Two mountingbracketswhichcanbe Zinc coatedsteel,powderbody Integral switchingforeaseofinstallation itted priortomaincase ertical tohorizontal for the3and4.0mm floor. Therecommendedcablesizesare2.5mm door ataheightofbetween1.8to2.25mfromthe key slotholesprovided.Fitdirectlyabovethe The unitscanbefixeddirectlytothewallusing ScreenHeat Electrical supply220-240V50Hzsinglephase. and adjustment. These versatilebracketsofferflexiblepositioning use thebracketsprovided. 2 for the4.5.For anadjustableoutlet • • R ScreenHeat 4.5 ef. 91470AW Two heatoutputs-2.25kWand4.5kW Features overtheScreenHeat3 Wiring Diagrams T ypical Specifications 2 on page188. o n page 173. 115

Xpelair ScreenHeat | Doorway hot air curtains Xpelair Whispair Commercial ceiling fan range

Key features The Range

Type: Commercial quality Originally designed to provide a cool ceiling level (or the apex of the roof) circulation of air during warm periods, and cooler air sinks to ground level. cooling and Xpelair Whispair is a popular choice for Xpelair Whispair fans will effectively destratification fans winter applications too, where their use destratisfy the hot air which gathers at as heat destratification units can reduce ceiling height by pushing it downwards heating costs. These commercial to mix with cooler air nearer to ground Application: Commercial/Industrial quality products are designed for use in level, thus providing a more uniform public buildings, shops, theme pubs, temperature profile from floor to Control options: Range of optional restaurants, village halls, churches, ceiling. This results in reduced heating hospitals, schools, farm buildings, costs as all the hot air does not gather controllers available factories, warehouses and other at ceiling height, and thermal losses commercial buildings. are reduced. The units should be set for downward airflow at low speed for Whispair are designed for worldwide optimum effect. use, including hot and humid conditions. The units are rated for For automatic control all Whispair have continuous operation in commercial integral anti-vibration bobbins and a applications at temperatures up to continuously rated capacitor start and 40ºC and are suitable for upwards or run external rotor motor. The motor downwards airflow. The triple bladed incorporates two sets of caged ball units are available in four sizes with bearings for extra long life. swept diameters from 900 to 1500mm. Fan blades are steel and are supplied The optional Xpelair ThermoMiser in matched sets. Whispair products or sensor control system can automatically fans are supplied with a choice of two compare high and low level lengths of suspension rod giving temperatures and ensure that the fans overall drops of 375 or 750mm. are operated to maximise energy efficiency. This controller should be In summer the atmosphere can sited where the ambient is less than become stifling hot. Whispair can 35ºC, with the two sensors fitted at high provide immediate relief by quietly and low level and connected using the delivering a continuous cooling breeze cables supplied. In summer the control over a wide area. To maximise the knob can be used to manually override benefit it is good practice to introduce the sensors for manual control. fresh air into the area. For no-frills speed control the Xpelair Whispair controllers are available for In winter stratification will naturally the control of a single fan or groups of occur in a room as hot air rises to up to 6 fans. Select the right product for your application

NWAN36 NWAN48 NWAN56 NWAN60

Reference number 90409AW 90410AW 90411AW 90412AW Remote optional controllers available n n n n Swept diameter (mm) 900 1200 1400 1500 Reversible operation nn n n Maximum speed (rpm) 350 310 280 260 Air delivery (m3/h) 8761 10890 12474 13959 Air delivery (l/s) 2434 3025 3465 3878 Electrical power rating (W) 50 65 65 65 Overall drop options (mm) 375/750 375/750 375/750 375/750 Weight (kg)* 6.5 6.5 6.5 6.5 Guarantee (years, UK) 2 2 2 2 *All models 6.5kg with marginal weight variance according to sweep diameter

116 Models Controllers

NWAN36 Xpelair Single Whispair Controller WAC1 1 to 10 Whispair units. Three slide switches Ref. 90409AW Ref. 21852AW provides On/Off operation and upwards or • 900mm diameter sweep fan for cooling or • Two slide switches provides On/Off downwards rotation, manual override destratification operation and 5 speed settings. Complete • Complete with fan running light with transformer controller for quiet operation • w210 x h86 x d45mm NWAN48 and ‘fan running’ indicator light Ref. 90410AW • 1200mm diameter sweep fan for cooling Xpelair Group Whispair Controller WAC6 or destratification Ref. 21853AW • For the simultaneous speed control of 1 to 6 NWAN56 Whispair units. Two slide switches provides Ref. 90411AW On/Off operation and infinitely available • 1400mm diameter sweep fan for cooling speed settings or destratification • Complete with ‘fan running’ indicator light NWAN60 Xpelair Group Whispair Reversing Ref. 90412AW Controller WAC6R • 1500mm diameter sweep fan for cooling Ref. 21878AW or destratification • For the simultaneous speed control of 1 to 6 Tip! For optimum performance of Xpelair Whispair units. Two slide switches provides Whispair choose a dedicated Xpelair controller. On/Off operation and infinitely variable speed settings. Complete with ‘fan running’ indicator light and choice of winter/summer upwards or downwards airflow

Xpelair Whispair Auto Temperature Controller AWC Ref. 21857AW • De-stratification controller supplied with two thermo sensors at high / low level monitoring on page 174. between preset minimum and maximum Typical Specifications Wiring Diagrams on page 188. values. For the simultaneous speed control of

Air Movement

Heat Layers Summer cooling Heat conservation e g n a r n a f g n i l i e c l a i

Dimensions (mm) c r

Whispair Range e m m

Dimensions (mm) o NWAN36 NWAN48 NWAN56 NWAN60 C Sweep Diameter 900 1200 1400 1500

Overall Drop All models, ceiling to bottom of fan: | 375 or 750 (two down rods supplied) r i a p s

Installation i h Which fan diameter do I choose? Spacing will vary according to individual and a half diameters from pillars and walls in

Whispair units are delivered with two building layout. As a rule of thumb, in the order to avoid turbulence unbalancing the unit W suspension rods. Ideally the fan blade should majority of temperate climate applications and causing it to sway. Check that the units are r be at 2700mm or more from the floor (but Xpelair Whispair should be spaced 4500 – clear of lighting to avoid strobe effects. i never less than 2400mm) and a minimum of 6000mm between blade tips apart. In hot and a A speed controller is recommended l 375mm from the ceiling. humid applications this should be reduced by a particularly for multi unit installations. e third. The units should be no closer that one p X 117 Xpelair Electrostatic Air Cleaners Surface and recessed models

EAC400

EACF400

Key features The Range

Type: Ceiling Mounted With the introduction of non-smoking As well as healthier air quality, Air Cleaners areas in public places, other Electrostatic Air Cleaners means less contaminants are now more evident. frequent cleaning and redecoration, Application: Pubs, clubs, resulting in lower costs. Suitable for commercial premises such restaurants, offices as pubs, restaurants, conference rooms, Xpelair Electrostatic Air Cleaners are a offices, meeting rooms and clubs. convenient way of dealing with Control: Remote handheld airbourne contaminants at source, so Xpelair Electrostatic Air Cleaners can preventing it migrating to other parts of be used on their own or as part of a the building. complete ventilation strategy. Ventilation relies on a flow of air across a space. They are easy to fit to a ceiling or can be Often in pubs and restaurants, the recessed where a suspended ceiling or design of nooks and alcoves so called ceiling void is available. ‘dead areas’ areas creates unventilated All units come complete with a hand spaces. The area around the dartboard held remote On/Off, speed control so tends to be a 'hot spot'; and at the bar it that the unit can be easily operated is good practice to counter stale by staff. moistair drifting towards serving staff. Airborne dust is also removed down to 0.01 microns.

Select the right product for your application

EAC400K EAC400W EAC700K EAC700W EACF400W

Reference number 89869AK 89861AW 89870AK 89862AW 90015AW

Ceiling mounting Surface Surface Surface Surface Recessed Air flow (m3/h) High 1000 1000 2000 2000 780 Medium 660 Low 400 400 1000 1000 420 Sound pressure level (dB(A)@3m) 58 58 60 60 58 Number of cells 1 1 2 2 1 Max electrical power (W) 115 115 300 300 275 Finish Black/woodgrain White Black/woodgrain White White Installed weight (kg) 19 19 32 32 24.5 Guarantee (years, UK) 1 1 1 1 1

118 Models

Electrostatic Air Cleaners EAC • Particle charger and aluminium electrostatic • Available for max. area of 40sqm Surface mounted on ceiling plate cell • Designed for unobtrusive installation in • Effective air distribution pattern suspended 600 x 600mm ceiling tiles Airflow: 400 to 1000m3/h • Complete with hand held infrared • Fascia grille may be painted to match the EAC400K remote control ceiling décor Ref: 89869AK • High efficiency fans • Mesh pre-filter Black/wood grain • Five speeds • Particle charger and aluminium electrostatic • Pre selectable start-up speed plate cell EAC400W • Status indicator panel. A 'wash' LED indicates • Effective air distribution pattern Ref:89861AW the needs to clean the cell and pre-filter • Three speeds White • Available in black/woodgrain finish or white • High efficiency fans For odour removal such as hairdressing Complete with hand held infrared Airflow: 1000 to 2000m3/h • • sprays, kitchens etc. an additional active remote control EAC700K carbon filter is available • Pre selectable start-up speed Ref: 89870AK • Fits both sizes of unit • Status indicator panel. A 'wash' LED Black/wood grain Ref: 89884AA indicates the needs to clean the cell and pre-filter Electrostatic Air Cleaners EACF EAC700W • Fascia colour: off white Ref: 89862AW Recess mounted

White s Airflow: 420 to 780m3/h l • Available in two sizes/outputs for max. areas EACF400W White e of 45sqm and 90sqm Ref: 90015AW Typical Specifications on page 174. d o • Mounting rails provide simple and

fast installation m Mesh pre-filter • d e s

Dimensions (mm) s e c

EAC400 Range EAC700 Range EACF400 e r d n a e c a f r u S | s

Installation r e n The design of an Air Cleaning System is Light Medium Heavy Step 4: a straightforward, involving a set sequence of 6 air cleans/hr 8 air cleans/hr 10 air Size and Number of Electrostatic Air e

steps: cleans/hr Cleaners l Step 1: Office Restaurant Pub The EAC flow rates as calculated should not C Volume of Affected Area or Room Computer Room Conference Room Social Club exceed the value obtained at the three quarter r

Determine overall volume of affected area or Foyer area Dance Hall speed setting. This ensures that the system i room. Restaurant/Bar designed has some additional capacity should A pollution conditions be abnormal.

Step 2: Step 3: Room Size 6mx4mx3m=72m3 c i

Rate of Air Cleans per Hour Total Air Clean Rate Air Cleans/hr 10 t 3 3

From the table, select the most appropriate Calculate the total air clean rate for the problem Total Air Clean Rate 10x72m =720m /h a hourly air clean rate. The rates listed relate to the area: 1 EAC400 is required for this area. t likely severity of the indoor pollution problem. Room Volume (m3) s

[Step 1]xRate of Air Cleans per Hour=(m3/hr) o Width x Length x Average Height =m3. [Step 2] r t c e l E r i a l e p X 119 Xpelair DigiPure Polarising air filtration NEW NEW

XAC690UC XAC420/480P

XAC550/910CC

XAC520/640W

Key features The Range

Type: Air Cleaners Indoor pollution is a growing problem Xpelair DigiPure uses a unique and with air inside our buildings being up patented air cleaning technology that Application: Pubs, clubs, to 100 times more polluted than removes up to 98% of airborne restaurants, offices outdoors. Sources of indoor pollution pollutants. Available in several unit include dust, mould spores, biological types, air is drawn though the unit Control options: Remote handheld contaminants, pollen, tobacco smoke capturing pollutants down to 0.01 (in care homes and private clubs) and micron leaving the air we breathe clean, volatile organic compounds. They are safe and healthy. The system uses especially dangerous to the elderly, polarising screens and removable high infants and allergy sufferers. Xpelair specification filters. The system does introduces ESSA a unique technology not use HEPA filters and produces no that cleans indoor air to ozone in the process. unprecedented levels without The technology has been endorsed producing harmful ozone. by the British Allergy Foundation Suitable for care homes, hospitals, (allergy UK). hotels, schools, surgeries, leisure facilities, offices and commercial premises where there is a responsibility to provide a safe and comfortable environment for those who use them.

Robust construction Easy access filters

Select the right product for your application

XAC420P XAC480P XAC520W XAC640W XAC550CC XAC910CC XAC690UC

Reference number 91215AA 91216AA 91217AA 91218AA 91219AA 91220AA 91221AA Type Portable Portable Wall unit Wall unit Cassette Cassette Under ceiling Airflow (m3/h) High 1526 1717 1872 2304 1962 3276 2480 Medium 1145 1336 1318 1724 1638 2628 2099 Low 763 954 763 1145 1314 1962 1717 Sound pressure level (dB(A)@3m) max2 48 48 35 35 35 48 56 Weight (kg) 19 28 12 14 26 38 24 Guarantee (years, UK) 2 2 2 2 2 2 2

120 Models

DigiPure Portable Models • For commercial and medical use • Quiet centrifugal fan • High wall cabinet style • Status indicator XAC420P • Large grille inlet area • Hand held remote control and louvre control Ref. 91215AA • Adjustable outlet louvre • Easy access to filter section 2 • Suitable for floor areas up to 84m • Removable washable pre-filter DigiPure Under-Ceiling Units XAC480P • Balanced tangential fan for quiet operation Ref. 91216AA • Status indicator XAC690UC • Suitable for floor areas up to 84m2 • Hand held remote control provides On/Off Ref. 91221AA • Ideal for medical / nursing home and 3 speed control • Suitable for floor areas up to 163m2 environments where the requirement is for DigiPure Ceiling Cassettes • For commercial and medical use usage in varying locations in conjunction with • Surface mounted to the ceiling other treatment XAC550CC • For floor areas up to 1750sq ft • Status indicator Ref. 91219AA • Attractive louvre outlets at both ends • On/Off and three speeds • Suitable for floor areas up to 130m2 • Quiet centrifugal fan • Fully mobile • Status indicator • Robust construction XAC910CC • Easy access filters Ref. 91220AA • Hand held remote control provides on-off 2 DigiPure Wall Models • Suitable for floor areas up to 204m and 3 speed control • For commercial and medical use XAC520W • Recess mounting for suspended ceilings * Replacement Essa filter medium available for Ref. 91217AA • Requires 330mm void all models Ref. 91316AA 2 • Suitable for floor areas up to 102m • Attractively styled fascia with safety XAC640W fingerguard Ref. 91218AA • Adjustable four way outlet louvres for even • Suitable for floor areas up to 135m2 room distribution Performance n o i t a r t l i f r i a g n i s i r a l o P |

Dimensions (mm) e r XAC520/640W XAC420/80P XAC550/910CC XAC690UC Dimensions (mm) u Model Width Depth Height P

A B C i

XAC420P 630 270 870 g

XAC480P 930 360 960 i XAC520W 1020 200 370 D XAC640W 1200 200 330

XAC550CC 640 640 33 r XAC910CC 950 950 50 i XAC690UC 950 830 140 a l e p X 121

Industrial Ventilation

Industrial fans are used in a agents such as bacteria and other Workplace (Health, Safety & Welfare) wide range of commercial and micro organisms. Regulations 1992 (section 6) and the associated AcOP requires effective and industrial applications to Effective ventilation has an important part suitable provision is made so that every provide a healthy and safe to play in reducing these risks. enclosed workplace is ventilated by a sufficient quantity of fresh air. environment in which to work. Xpelair offers a comprehensive range of industrial products and associated Control of Substances Hazardous to Although no maximum temperature is ventilation accessories and controls, Health (COSHH) Regulations are specified in the Regulations, an accepted which can be combined to design particularly relevant to industrial zone of thermal comfort is between bespoke systems to suit a wide range of processes. Introduced in 2002 and 16-24ºC. specific ventilation applications. amended in 2005 they require employers Building design, shading, supply & in all workplaces to control exposure to Once a system is installed COSHH extract ventilation, destratification and air substances to prevent ill health. Regulations require it to be used and circulation can be combined to provide a Substances include adhesives, maintained, so access for routine, comfortable, healthy workplace cleaning agents, fumes from soldering documented inspection is also an environment. and welding, naturally occurring important consideration. substances such as dust and biological

122 Industrial Ventilation

Scimitar XPMS Scimitar XSCS Rapier XPMA Rapier XSCA Rapier XRA XMV XID

Page Number 124 126 128 130 132 134 136 Fan type Plate mounted Short case Plate mounted Short case Roof fan Mixed flow Metal axial axial axial axial & cowl roof inline Positioning Wall / ceiling Ducted Wall / ceiling Ducted Roof Roof Above ceiling Models 14 12 11 11 6296 Max diameter (mm) 630 630 710 710 630 450 315 Max extract rate (m3/s) 2.40 2.40 4.56 4.56 2.95 1.55 0.46 Max power (W) 400 400 890 890 600 1100 240

NEW NEW NEW NEW

XIDPXpress MinimX C LoSound C CubeX C HiFlo CMAX ManCoolers n

Page Number 138 142 144 146 148 150 152 o i

Fan type Plastic inline Mixed flow Compact Attenuated Versatile Attenuated Air circulation t inline inline inline attenuated inline inline a l

Positioning Above ceiling Above ceiling Above ceiling Above ceiling Above ceiling Above ceiling Free standing/ i

Suspended t

Models 6 4 6 6 8 97 n

Max diameter (mm) 315 355 315 355 450 400 560 e 3

Max extract rate (m /s) 0.38 1.36 0.41 0.69 1.13 1.05 3.06 V

Max power (W) 300 870 290 880 950 1240 550 l a For Industrial Controllers & Accessories see pages 154 - 159 i r t s u d n

www.xpelair.co.uk 123 I Xpelair Scimitar XPMS Sickle blade plate fans

Key features The Range

Type: Plate mounted axial Xpelair introduces a new generation of The robust wall plate incorporates a sickle blade fans designed for a wide bellmouth entry and four fixing points for range of commercial and industrial simple installation. Application: Commercial/Industrial ventilation applications. And for safety a roomside protective Control options: Electronic/Transformer The blade design optimises airflow finger guard is fitted as standard. performance whilst minimising speed control The Scimitar range can be installed at sound levels. any angle and is fully speed controllable. The blades are directly mounted to Plate mounted XPMS fans are supplied in capacitor start and run external rotor Form A running. motors and then dynamically balanced.

Models

• Plate and bellmouth: One piece • Fully speed controllable except galvanised steel pressing with corrosion XPMS315-12 resistant powder coat finish. Robust steel • Safety thermal overload protection as fingerguard to BS 848 Part 5 / EN 294 standard with terminals provided for • Impeller: Press steel sickle blade design connection for high performance and low noise • Protected to IP44 • Blades are dynamically balanced to ISO • Connection terminal box to IP54 1940 -1: 1986 Grade G 6.3 • Can be wired for reverse operation (with • Motor: Totally enclosed capacitor start & reduction in performance) run external rotor motor. Ball/Roller • Suitable for ambient temperatures from bearings are sealed for life -30ºC to +60ºC • Insulation is to class F 315mm are class B • Supply voltage: 220 -240v 50Hz Select the right product for your application

XPMS315-12 XPMS315-14 XPMS355-14 XPMS400-14 XPMS450-14

Reference number 91526AA 91527AA 91529AA 91530AA 91532AA Fan blade diameter (mm) 315 315 355 400 450 No. poles 2 4 4 4 4 Nominal fan speed (rpm) 2800 1410 1365 1400 1400 Extract performance (FID, m3/s) 0Pa 1.06 0.68 0.90 1.39 1.87 25Pa 1.03 0.62 0.78 1.26 1.76 50Pa 0.99 0.49 0.69 1.15 1.63 75Pa 0.94 0.30 0.56 1.03 1.52 100Pa 0.90 0.83 1.39 125Pa 0.86 0.47 0.90 150Pa 0.82 175Pa 0.78 Sound pressure level (dB(A) @3m) 68 54 54 61 67 Max electrical power rating (W) 360 120 180 300 470 Electrical current FLC (A) 1.58 0.56 0.78 1.35 2.20 Electrical current SC (A) 3.70 1.40 1.20 2.80 5.30 5 step speed controller 91367AA 91367AA 91367AA 91367AA Electronic speed controller 89903AA 89903AA 89903AA 89904AA Guarantee (years) 2 2 2 2 2

124 Controllers Dimensions (mm)

Industrial Fan Controller XCW Dimensions (mm) • Electronic speed control Model A B C ØD ØE F G H • Provides On/Off and infinitely variable XPMS315 430 380 9 324 330 100 70 81 speed control XPMS355 485 435 9 360 385 113 75 87 • Fan operation indicator light XPMS400 540 490 9 412 420 130 88 90 • Surface or recess mounting • w160 x h86mm XPMS450 575 535 11 463 480 126 96 110 XPMS500 655 615 11 517 535 198 104 120 5 Step Transformer Speed Controller XPMS560 725 675 11 568 600 223 119 135 • Multi-tapped auto transformer giving 5 XPMS630 805 750 11 643 670 275 130 150 stepped speeds allowing accurate adjustment to suit site conditions • Provides five speed and On/Off function • Robust ISO casing • IPX4 protected • Size Installation and Accessories

Xpelair XPMS Plate fans can be installed at any XLS External Louvre Shutter angle. Installation through a outside wall should XLS315 (XPMS315) Ref. 89905AA be with a finger guard if below 2.5 m with XLS350 (XPMS350) Ref. 91144AA Typical Specifications on page 175. suitable external weather protection. Either an XLS400 (XPMS400) Ref. 89906AA Wiring Diagrams on page 188. external louvre type EG or a louvre shutter type XLS450 (XPMS450) Ref. 89907AA Control Details on pages 154. XLS. Details on page 156. XLS500 (XPMS500) Ref. 90540AA XLS670 (XPMS630) Ref. 90541AA

Performance

XPMS250 to 450 XPMS500 to 630

X P M S 3 1 5 - 1 s 2 n

X ] ] a

P a

a M f S P P 4 [ [ 50 X - e P e 1 r M

r 4 u

S e u

s 5 s t s 6 s X 0 e

e P - M r r S 1 a 4 P 4 P 0 0- l 1 c c

4 i i t t X X a

a P p

t P t M M S S S5 S 60 63

- 0 e 16 - 16

X d PM XP S4 M X X X 5 S P P 0 a M P -1 5 M 6 0 l S M 0 S X 4 - 0 S 1 5 P 0 6 0

- b M 1 3 6 5 0 S - 5 1 3 - 4 1 1 5 4 e

- l 1 4 k c i

3 3

Airflow [m /s] Airflow [m /s] S

Select the right product for your application |

XPMS500-14 XPMS560-14 XPMS400-16 XPMS450-16 XPMS500-16 XPMS560-16 XPMS630-16 S

Reference number 91534AA 91536AA 91531AA 91533AA 91535AA 91537AA 91539AA P

Fan blade diameter (mm) 500 560 400 450 850 560 630 M No. poles 4 4 6 6 6 6 6 Nominal fan speed (rpm) 1347 1300 940 980 850 940 870 X 3 Extract performance (FID, m /s) 0Pa 2.31 3.15 0.91 1.31 1.55 2.28 2.78 r

25Pa 2.16 2.97 0.75 1.13 1.39 2.08 2.27 a

50Pa 2.05 2.77 0.47 0.89 1.11 1.85 1.67 t 75Pa 1.84 2.55 1.60 1.11 i 100Pa 1.67 2.30 1.18 m

125Pa 1.44 2.01 i

150Pa 1.00 1.72 c Sound pressure level (dB(A) @3m) 66 62 54 58 56 55 55 S Max electrical power rating (W) 953 1049 140 200 230 446 560

Electrical current FLC (A) 4.80 4.50 0.89 0.94 1.05 2.10 2.50 r i Electrical current SC (A) 5.90 6.50 0.90 1.50 1.65 4.50 4.70 a

5 step speed controller 91369AA 91369AA 91367AA 91367AA 91367AA 91368AA 91368AA l Electronic speed controller 89903AA 89903AA 89904AA 89904AA e Guarantee (years) 2 2 2 2 2 22 p X 125 Xpelair Scimitar XSCS Sickle blade short case fans

Key features The Range

Type: Short case axial Xpelair introduces a new generation of The robust short case is rolled and sickle blade fans designed for a wide electro welded with rolled flanges. range of commercial and industrial Application: Commercial/Industrial Cased units are supplied in form B ducted ventilation applications. running with motor downstream. The blade design optimises airflow Control options: Electronic/Transformer The Scimitar range can be installed at performance whilst minimising speed control any angle and is fully speed controllable. sound levels.

The blades are directly mounted to capacitor start and run external rotor motors and then dynamically balanced.

Models

• Casing: Compact and robust construction • Safety thermal overload protection as with corrosion resistant powder coat finish standard with terminals provided for • Impeller: Press steel sickle blade design connection for high performance and low noise • Protected to IP44 • Blades are dynamically balanced to ISO • Connection terminal box to IP54 1940 -1: 1986 Grade G 6.3 • Can be wired for reverse operation (with • Motor: Totally enclosed capacitor start & reduction in performance) run external rotor motor. Bearings are • Suitable for ambient temperatures from - sealed for life 30ºC to +60ºC • Insulation is to class F • Supply voltage: 220-240V 50Hz • Fully speed controllable except XSCS315-12 Select the right product for your application

XSCS315-12 XSCS315-14 XSCS355-14 XSCS400-14 XSCS450-14

Reference number 91570AA 91571AA 91573AA 91574AA 91576AA Fan blade diameter (mm) 315 315 355 400 450 No. poles 2 4 4 4 4 Nominal fan speed (rpm) 2800 1410 1365 1400 1400 Extract performance (FID, m3/s) 0Pa 1.06 0.68 0.90 1.18 1.97 25Pa 1.03 0.62 0.78 1.14 1.90 50Pa 0.99 0.49 0.69 1.02 1.76 75Pa 0.94 0.30 0.56 0.87 1.53 100Pa 0.90 0.69 1.22 125Pa 0.86 150Pa 0.82 175Pa 0.78 Sound pressure level (dB(A) @3m) 63 49 54 59 60 Max electrical power rating (W) 360 100 130 160 500 Electrical current FLC (A) 1.58 0.52 0.58 0.73 2.20 Electrical current SC (A) 3.70 1.40 1.40 2.00 4.50 5 step speed controller 91367AA 91367AA 91367AA 91367AA Electronic speed controller 89903AA 89903AA 89903AA 89904AA Guarantee (years) 2 2 2 2 2

126 Controllers Dimensions (mm) Installation and Accessories

Industrial Fan Controller XCW For ducted applications coupling flanges, mounting feet and anti-vibration mounts are • Electronic speed control recommended. These are supplied in the Short • Provides On/Off and infinitely variable Case Axial Fan Xtras installation packs comprising speed control of 2 steel matching coupling flanges, 2 flexible • Fan operation indicator light • Surface or recess mounting connectors, 4 worm drive clips, 2 mounting feet • w160 x h86mm and 4 anti-vibration mounts.

5 Step Transformer Speed Controller Cased Axial Installation Packs Fan size • Multi-tapped auto transformer giving 5 stepped speeds allowing accurate 315mm Ref. 91317AA adjustment to suit site conditions 350mm Ref. 91318AA • Provides five speed and On/Off function 400mm Ref. 91319AA • Robust ISO casing Dimensions (mm) 450mm Ref. 91320AA • IPX4 protected Model ØAB ØC ØD ØE F G H 500mm Ref. 91321AA XSCS315 366 8x45º 12 317 398 135 72 6 560mm Ref. 91322AA XSCS355 405 8x45º 12 356 438 135 72 6 XSCS400 448 12x30º 12 400 484 155 72 6 XSCS450 497 12x30º 12 451 534 160 72 6 XSCS500 551 12x30º 12 503 584 165 72 6 Typical Specifications on page 175. XSCS560 629 16x22.5º 14 559 664 210 72 6 Wiring Diagrams on page 189. XSCS630 698 16x22.5º 14 634 734 220 72 6 Control Details on page 154.

Performance

XSCS250 to 450 XSCS500 to 630 s X S C n S

3 a 1 5 f - 1 2 e s ] a ] a a P P c [ [ e e

r X r S t u

u C

X s r s S S s s C 5 e 6 e S r

r 0 4 - o P

P 0 1 0 4 c

c - i i 1 h t t 4 a a X t t

X S s S S C SC S S4 5 50 60 -1 - e 4 16 XS CS d 45 X X X 0- S S 1 X C S 6 C a S C S S 4 6 l X 00 S X C 3 S -1 3 S S 0- C 6 5 C 5 1 b S 5 S 0 6 3 - 5 0 1 0 - 1 1 5 4 0

4 e - -1 1 6 l 4 k c i S

Select the right product for your application |

XSCS500-14 XSCS560-14 XSCS400-16 XSCS450-16 XSCS500-16 XSCS560-16 XSCS630-16 S

Reference number 91578AA 91580AA 91575AA 91577AA 91579AA 91581AA 91583AA C Fan blade diameter (mm) 500 560 400 450 500 560 630 S No. poles 4 4 6 6 6 6 6 Nominal fan speed (rpm) 1347 1300 940 980 850 940 870 X 3 Extract performance (FID, m /s) 0Pa 2.69 3.15 0.91 1.31 1.77 2.28 3.46 r

25Pa 2.57 2.97 0.75 1.13 1.61 2.08 3.19 a

50Pa 2.43 2.77 0.47 0.89 1.31 1.85 2.89 t 75Pa 2.22 2.55 1.60 2.43 i 100Pa 1.99 2.30 1.18 m

125Pa 1.76 2.01 i

150Pa 1.72 c Sound pressure level (dB(A) @3m) 61 57 49 53 51 55 55 S Max electrical power rating (W) 760 1010 140 200 340 440 770

Electrical current FLC (A) 3.30 4.60 0.62 0.92 1.65 1.96 3.50 r i Electrical current SC (A) 6.20 7.30 0.90 1.50 2.90 5.20 5.20 a

5 step speed controller 91369AA 91369AA 91367AA 91367AA 91367AA 91368AA 91368AA l Electronic speed controller 89903AA 89903AA 89904AA 89904AA e Guarantee (years) 2 2 2 2 2 2 2 p X 127 Xpelair Rapier XPMA Plate mounted axial fans

Key features The Range

Type: Plate mounted axial Xpelair Rapier is a new range of cast At the heart of the unit is a proven aluminium aerofoil blade section plate capacitor start and run Class F external Application: Commercial/Industrial fans which now extends from 315mm to rotor motor cast aluminium blade 710mm. The range has also been assembly. extended to include 4 and 6 pole The wall plate with bellmouth entry is Control options: Electronic/Transformer versions. speed control manufactured in pressed steel with a Rapier plate fans are suitable for wall corrosion resistant powder coated finish. mounting and short duct in larger areas For safety the front is protected by a in commercial, agricultural and high robust finger guard. performance industrial installations including kitchens, factories, garages and All Xpelair Rapier fans are fully speed warehouses. controllable.

Models

• Aerofoil axial plate fan • Bearings are sealed for life • Plate and bellmouth - one piece • Fully speed controllable except XPMA galvanised pressing with corrosion 315-12 resistant two stagepowder coat RAL 9005 • Class F insulation finish. Steel fingerguard to EN 294 • Safety thermal overload protection as • Impeller - aerofoil section cast aluminium standard with terminals provide for • Dynamically balanced to G6,3 ISO 1940 connection part 1for high performance, low noise • Can be installed at any angle. Suitable for • Totally enclosed capacitor start and run ambient temperatures of -30 to +60ºC IP54 external rotor motor • Supply 220-240V 50Hz Select the right product for your application

XPMA315-12 XPMA315-14 XPMA355-14 XPMA400-14 XPMA450-14 XPMA500-14 XPMA400-16

Reference number 91540AA 91541AA 91543AA 91545AA 91547AA 91049AA 91546AA Fan blade diameter (mm) 315 315 350 400 450 500 400 No. poles 2 4 4 4 4 4 4 Nominal fan speed (rpm) 2650 1400 1330 1350 1370 1290 940 Extract performance (FID, m3/s) 0Pa 1.06 0.61 0.96 1.44 1.75 2.24 1.39 25Pa 1.02 0.57 0.86 1.33 1.64 2.12 0.81 50Pa 0.99 0.50 0.76 1.19 1.53 1.97 75Pa 0.95 0.40 1.39 1.81 100Pa 0.92 1.18 1.60 125Pa 0.88 1.26 150Pa 0.84 175Pa 0.79 Sound pressure level (dB(A) @3m) 61 48 53 58 58 60 48 Max electrical power rating (W) 470 130 190 290 360 510 130 Electrical current FLC (A) 2.1 0.59 0.84 1.45 1.6 2.3 0.6 Electrical current SC (A) 6 1.5 1.45 2.4 3.6 4.3 1.4 5 step speed controller 91367AA 91367AA 91367AA 91368AA 91367AA 91367AA Electronic speed controller 89903AA 89903AA Guarantee (years) 2 2 2 2 2 2 2

128 Controllers Dimensions (mm) Installation and Accessories

Industrial Fan Controller XCW Xpelair XPMA fans can be installed at any angle. Installation through an outside wall should be • Electronic speed control • Provides On/Off and infinitely variable with a finger guard if below 2.5m and suitable speed control external weather protection. Either an external • Fan operation indicator light louvre type EG or a louvre shutter type XLS. • Surface or recess mounting • w160 x h86mm XLS External Louvre Shutter 5 Step Transformer Speed Controller XLS315 (XPMA315) Ref. 89905AA XLS350 (XPMA355) Ref. 91144AA • Multi-tapped auto transformer giving 5 XLS400 (XPMA400) Ref. 89906AA stepped speeds allowing accurate XLS450 (XPMA450) Ref. 89907AA adjustment to suit site conditions XLS500 (XPMA500) Ref. 90540AA • Provides five speed and On/Off function XLS670 (XPMA630) Ref. 90541AA • Robust ISO casing Dimensions (mm) • IPX4 protected Model A B ØC ØD ØE F G H XPMA315 430 380 9 320 328 69 24 11 XPMA355 485 435 9 367 372 75 24 12 XPMA400 540 490 9 412 420 88 25 12 XPMA450 575 535 11 463 480 96 28 14 XPMA500 655 615 11 517 528 104 77 16 XPMA560 725 675 11 568 589 119 60 16 Typical Specifications on page 175. XPMA630 805 750 11 643 670 130 64 20 Wiring Diagrams on page 188. XPMA710 850 810 14.5 720 763 150 37 20 Control Details on pages 154.

Performance s n a f l a i x a d e t n u o m e Select the right product for your application t a l

XPMA450-16 XPMA500-16 XPMA560-16 XPMA630-16 XPMA710-16 P

Reference number 91548AA 91549AA 91551AA 91050AA 91553AA | Fan blade diameter (mm) 450 500 560 630 710

No. poles 6 6 6 6 6 A Nominal fan speed (rpm) 930 920 880 880 850 Extract performance (FID, m3/s) 0Pa 1.18 1.54 2.47 3.35 4.56 M

25Pa 1.04 1.35 2.22 3.08 4.31 P

50Pa 0.79 1.03 1.93 2.77 3.89 X 75Pa 1.50 2.34 3.47 r 100Pa e

125Pa i 150Pa p 175Pa a Sound pressure level (dB(A) @3m) 49 54 55 59 61 Max electrical power rating (W) 170 200 430 600 890 R

Electrical current FLC (A) 0.75 0.96 1.95 2.7 4.1 r Electrical current SC (A) 1.5 2.7 4.6 5.3 8 i

5 step speed controller 91367AA 91367AA 91368AA 91368AA 91369AA a l Electronic speed controller 89903AA e Guarantee (years) 2 2 2 2 2 p X 129 Xpelair Rapier XSCA Short case axial fans

Key features The Range

Type: Short case axial Xpelair XSCA is a high performance external rotor motor and die cast impeller range of sixteen compact and efficient assembly designed for high aluminium Application: Commercial/Industrial industrial aerofoil axial cased fans blade impeller assembly designed for featuring external rotor motors and high high output performance with low noise. pressure axial blade impellers. Control options: Electronic/Transformer The casing is manufactured in galvanised speed control Suitable for medium pressure, low noise steel with a corrosion resistant powder ducted applications in commercial, coated finish and the terminal box IP54 agricultural and high performance making it suitable for external applications. industrial installations including kitchens, The units are fully speed controllable. factories, garages and warehouses.

At the heart of the XSCA range is a proven capacitor start and run Class F

Models

• Casing: Compact and robust construction • Safety thermal overload protection as with corrosion resistant powder coat finish standard with terminals provided for to RAL9005 - black connection • Impeller: Die cast, high efficiency aerofoil • Protected to IP54 blade design for high performance and • Connection terminal box fitted to the low noise. Blades are dynamically outside of the case balanced to ISO 1940 -1: Grade G 6.3 • Can be wired for reverse operation (with • Motor: Totally enclosed capacitor start & reduction in performance) run external rotor motor • Suitable for ambient temperatures from • Insulation is to class F -30ºC to +60ºC • Bearings are sealed for life • Supply voltage: 220 -240V 50Hz • Fully speed controllable except Select the right product for your application XSCA315-12

XSCA315-12 XSCA315-14 XSCA355-14 XSCA400-14 XSCA450-14 XSCA500-14

Reference number 91584AA 91585AA 91587AA 91589AA 91591AA 91078AA Fan blade diameter (mm) 315 315 350 400 450 500 No. poles 2 4 4 4 4 4 Nominal fan speed (rpm) 2650 1400 1330 1350 1370 1290 Extract performance (FID, m3/s) 0Pa 1.06 0.61 0.96 1.44 1.75 2.24 25Pa 1.01 0.57 0.86 1.33 1.64 2.12 50Pa 0.99 0.50 0.76 1.19 1.53 1.97 75Pa 0.94 0.40 1.39 1.81 100Pa 0.92 1.18 1.60 125Pa 0.88 1.26 150Pa 0.83 175Pa 0.78 Sound pressure level (dB(A) @3m) 61 48 53 58 58 60 Max electrical power rating (W) 470 130 190 290 360 510 Electrical current FLC (A) 2.1 0.59 0.84 1.45 1.6 2.3 Electrical current SC (A) 6 1.5 1.45 2.4 3.6 4.3 5 step speed controller 91367AA 91367AA 91367AA 91368AA 91367AA Electronic speed controller 89903AA Guarantee (years) 2 22222

130 Controllers Dimensions (mm) Installation and Accessories

Industrial Fan Controller XCW For ducted applications coupling flanges, mounting feet and anti-vibration mounts are • Electronic speed control recommended. These are supplied in the Short • Provides On/Off and infinitely variable speed Case Axial Fan Xtras installation packs control comprising of 2 steel matching coupling flanges, • Fan operation indicator light • Surface or recess mounting 2 flexible connectors, 4 worm drive clips, 2 • w160 x h86mm mounting feet and 4 anti-vibration mounts.

5 Step Transformer Speed Controller Cased Axial Installation Packs Fan size • Multi-tapped auto transformer giving 5 stepped speeds allowing accurate 315mm Ref. 91317AA adjustment to suit site conditions 350mm Ref. 91318AA • Provides five speed and On/Off function 400mm Ref. 91319AA • Robust ISO casing 450mm Ref. 91320AA • IPX4 protected Dimensions (mm) 500mm Ref. 91321AA Model ØA ØB ØC ØD EF G 560mm Ref. 91322AA XSCA315 382 316.5 9.5 356 135 8x45º 6 XSCA355 421 356 9.5 395 135 8x45º 6 XSCA400 466 400 9.5 438 155 12x30º 6 XSCA450 515 451 9.5 487 160 12x30º 6 XSCA500 567 503 9.5 541 165 12x30º 6 XSCA560 635 559 11.5 605 210 16x22.5º 8 Typical Specifications on page 176. XSCA630 707 634 11.5 674 220 16x22.5º 8 Wiring Diagrams on page 189. XSCA710 785 711 11.5 751 260 16x22.5º 10 Control Details on pages 154.

Performance s n a f l a i x a e s a c t r

Select the right product for your application o h XSCA400-16 XSCA450-16 XSCA500-16 XSCA560-16 XSCA630-16 XSCA710-16 S

Reference number 91590AA 91592AA 91593AA 91594AA 91595AA 91597AA | Fan blade diameter (mm) 400 450 500 560 630 710 No. poles 6 6 6 6 6 6

Nominal fan speed (rpm) 940 930 920 880 880 850 A 3 Extract performance (FID, m /s) 0Pa 1.39 1.18 1.54 2.47 3.35 4.56 C 25Pa 0.81 1.04 1.35 2.22 3.08 4.31 S 50Pa 0.79 1.03 1.93 2.77 3.89 75Pa 1.50 2.34 3.47 X

100Pa r

125Pa e 150Pa i 175Pa p

Sound pressure level (dB(A) @3m) 48 49 54 55 59 61 a

Max electrical power rating (W) 130 170 200 430 600 890 R Electrical current FLC (A) 0.6 0.75 0.96 1.95 2.7 4.1 r

Electrical current SC (A) 1.4 1.5 2.7 4.6 5.3 8 i

5 step speed controller 91367AA 91367AA 91367AA 91368AA 91368AA 91369AA a Electronic speed controller 89903AA 89903AA l

Guarantee (years) 2 2 2 2 2 2 e p X 131 Xpelair Rapier XRA Axial roof fans

Key features The Range

Type: Roof fan and cowl The XRA is a versatile range of six rotor motor and blade impeller assembly compact and efficient industrial roof axial designed to run efficiently with the fans featuring external rotor motors and minimum of noise. On all models the Application: Commercial/Industrial high pressure axial blade impellers. impellers are die cast aerofoil section.

Control options: Electronic/Transformer The fans are suitable for roof extract The plate, bellmouth entry and finger speed control applications in commercial agricultural guard are manufactured in galvanised and high performance industrial steel with a corrosion resistant powder installations including kitchens, factories, coated finish and each of the units is fully garages and warehouses. The cowl and speed controllable. base assemblies are made of tough and As part of our desire to develop durable polymer that will resist exposure increasingly sustainable products the to ultraviolet light. Xpelair XRA and XMV roof cowls are now Central to the XRA range is a proven 100% recyclable. capacitor start-and-run Class F external

Models

• Roof cowl and base are manufactured • Motor - totally enclosed capacitor start from fibreglass with a gloss UV & run external rotor motor stable finish • Bearings are sealed for life • Colour - goose wing grey • Fully speed controllable except • Complete with integral birdguard XRA315-12 • Plate and bellmouth: one piece galvanised • Insulation is to Class F steel pressing with corrosion resistant • Safety thermal overload protection as powder coat finish. Robust steel standard with terminals provided for fingerguard to EN 294 connection. • Impeller - die cast, high efficiency aerofoil • Protected to IP54 bade design for performance and low • Connection terminal box IPX4 noise. Blades are dynamically balanced to • Suitable for ambient temperatures from - ISO 1940-1: 1986 Grade G 6.3 30ºC to +60ºC • Supply voltage: 220-240V 50Hz Select the right product for your application

XRA315-12 XRA355-14 XRA400-14 XRA450-14 XRA500-16 XRA630-16

Reference number 91997AA 91998AA 91999AA 92000AA 92001AA 91340AA Fan blade diameter (mm) 315 350 400 450 500 630 No. poles 2 4 4 4 6 6 Nominal fan speed (rpm) 2650 1330 1350 1370 880 880 Extract performance (FID, m3/s) 0.98 0.89 1.30 1.58 2.23 2.95 Sound pressure level (dB(A)@3m) 61 53 58 58 54 59 Max electrical power rating (kW) 0.13 0.19 0.29 0.36 0.2 0.6 Electrical current FLC (A) 2.1 0.84 1.45 1.6 0.96 2.7 Electrical current SC (A) 6 1.45 2.4 3.6 2.7 5.3 5 step speed controller 91367AA 91367AA 91368AA 91367AA 91368AA Electronic speed controller 89903AA Includes XRC roof cowl nn n n nn Guarantee (years, UK) 2 2 2 2 2 2

132 Controllers & Accessories Dimensions (mm)

Industrial Fan Controller XCW XRC Roof Cowls Without Fan XRA Range

• Electronic speed control XRC315-350 Ref. 91051AA A • Provides On/Off and infinitely variable XRC400-450 Ref. 91053AA speed control XRC500-560 Ref. 91055AA • Fan operation indicator light XRC630-710 Ref. 91056AA

• Surface or recess mounting XRC800-1000 Ref. 92195AA C • w160 x h86mm • Cowl and base manufactured in fibreglass

with glass UV stable finish G • Colour - Goose wing Grey F • Suitable for air inlet or out applications • See page 113 for cowl dimensions and curb details E D B 5 Step Transformer Speed Controller • Multi-tapped auto transformer giving 5 MODEL A B C D E F G speeds allowing accurate adjustment to suit XRA315 737 737 368 650 450 100 100 site conditions XRA355 737 737 368 650 450 100 100 • Provides five speed and On/Off function XRA400 830 830 410 750 550 100 100 • Robust ISO casing XRA450 830 830 410 750 550 100 100 • IPX4 protected XRA500 1000 1000 466 850 650 100 100 XRA560 1000 1000 466 850 650 100 100 XRA630 1100 1100 608 990 790 100 100 XRA710 1100 1100 608 990 790 100 100 XRA800 1403 1403 705 1300 1100 100 100 XRA1000 1403 1403 705 1300 1100 100 100

Typical Specifications on page 176. Wiring Diagrams on page 188. Control Details on pages 154.

Performance

XRA single phase

X

R

A

3

1

5

- s

1

2 n a f f o o r l a i x ] a P [ A e r u s s e | r P c i t a t S A

X

R R A 4 0 X 0 X - R 1 A 4 5 0 r 0 - X 1 R 6 e

A

4 i 5 0 X - R p 1 A 6 4 3 X 0 R -1 a A 6 3 5

5 R - 1 4 r i a l

Airflow [m3/s] e p X 133 Xpelair XMV Mixed flow vertical discharge roof fans

Key features The Range

Type: Mixed flow roof The Xpelair roof mounted mixed flow overload protection and an integral vertical discharge roof XMV range is an service isolator. The tough mouldings are Application: Commercial/Industrial ideal solution for the ventilation of high manufactured in High density temperature applications up to 100°C, polyethylene which is UV stabilised, such as commercial kitchens, in-store resistant to all weather conditions down Control options: Starters/Transformer bakeries, school kiln rooms and a wide to -30°C and, to meet regulatory speed control range of industrial processes. requirements, is 100% recyclable. Designed for horizontal installation on By including a high velocity vertical roofs, the XMV range features a unique discharge pattern in the design of the high performance aluminium-polyamide XMV range, Xpelair has minimised the mixed flow impeller and twin-wall casing risk of extracted air re-entering design. This construction and a motor the building. located out of the air-stream means it can Supply voltage: 220-240V 50Hz. be used with air-duct temperatures of up to 100°C. As part of our desire to develop increasingly sustainable products the The XMV range is available in six Xpelair XRA and XMV roof cowls are now diameters from 225mm to 500mm all with 100% recyclable. IP55 Class F motors, safety thermal

Select the right product for your application

XMV225-14 XMV250-14 XMV315-14 XMV400-14 XMV225-16 XMV250-16 XMV315-16 XMV400-16 XMV450-16

Reference number 91346AW 91347AW 91348AW 91349AW 91356AW 91357AW 91358AW 91359AW 91360AW Diameter (mm) 225 250 315 400 225 250 315 400 450 4 or 6 pole 444 4 6 66 66 Nominal fan speed 1400 1400 1400 1400 900 900 900 900 900 Extract performance (m3/s) 0Pa 0.53 0.83 1.25 1.48 0.35 0.53 0.79 0.98 1.55 50Pa 0.46 0.76 1.18 1.44 0.26 0.46 0.68 0.89 1.43 100Pa 0.41 0.69 1.11 1.34 0.11 0.30 0.47 0.72 1.25 150Pa 0.32 0.62 1.00 1.16 0.18 0.50 1.06 200Pa 0.20 0.53 0.89 1.07 0.40 0.83 250Pa 0.39 0.69 0.90 0.46 300Pa 0.14 0.55 0.75 350Pa 0.21 0.56 400Pa 0.27 450Pa 500Pa Sound pressure level (dB(A)@3m) 48 52 56 58 48 52 56 58 60 Max electrical power (kW) 0.09 0.18 0.37 0.55 0.09 0.18 0.37 0.55 1.1 Running current (A) 0.8 1.8 2.6 3.4 0.34 0.63 1.1 1.5 2.6 5 step transformer (Ref.) 91367AA 91368AA 91368AA 91369AA 91367AA 91367AA 91367AA 91368AA 91368AA Starter (Ref.) 91372AA 91372AA 91372AA 91372AA 91372AA 91372AA 91372AA 91372AA 91372AA Weight (kg) 12 15 18 21 12 15 18 21 26 Guarantee (years, UK) 2 2 2 2 2 2 2 2 2

134 Dimensions (mm)

XMV Range Dimensions (mm) Model A B C D E F G XMV225 466 622 425 415 40 75 330 XMV250 540 710 565 435 40 100 450 XMV315 588 768 565 500 40 100 450 XMV400 640 860 645 550 40 120 535 XMV450 740 990 710 640 50 120 590

Typical Specifications on page 176. Wiring Diagrams on page 189.

Performance

XMV225 XMV250

XMV315 s

XMV400 n a f f o o r e g r a h c s i d l a c i t r e v

XMV450 w o l f d e x i M | V M X r i a l e p X 135 Xpelair XID Centrifugal metal inline fans

Key features The Range

Type: Metal inline Inline duct systems have grown in The range is manufactured in zinc coated popularity as a method of concealed corrosion resistant sheet metal with Application: Commercial/Industrial ducted ventilation over the past two 30mm long spigot connections for ease decades. The Xpelair XID inline range is of connection to ductwork. engineered for trouble free operation, The range benefits from external rotor Control options: Speed control and delivered complete with adjustable motor and impeller assemblies, whilst the humidity/PIR sensing mounting brackets and terminal box. connection box is easily accessible on The practical, reliable fans are ideal for top of the unit. The fan unit is speed ducted applications in shops, schools, controllable to offer flexibility and factories, offices, pubs, hotels, individual control. restaurants and kitchens. They are A full choice of ventilation accessories is available in 100-315mm duct size available to complement this range to diameters to suit any application. design a complete system.

Models

• Compact and robust zintec steel • Insulation Class F. Fitted with safety construction thermal overload protection - protected • Pressure developing, centrifugal inline fans to IPX4 suitable for extract or intake applications • Impeller is backward curved • Extra length 30mm spigots • Supply voltage: 220-240V 50Hz • Can be mounted at any angle using the universal mounting bracket supplied • External rotor motor - totally enclosed and lubricated for life

Select the right product for your application

XID100 XID125 XID150 XID200 XID250 XID315

Reference number 90101AA 90102AA 90103AA 90104AA 90208AA 90106AA Spigot diameter (mm) 97 123 147 197 247 312 Extract performance (m3/s) 0Pa 0.08 0.11 0.17 0.29 0.34 0.46 100Pa 0.06 0.09 0.12 0.23 0.29 0.41 200Pa 0.04 0.06 0.07 0.17 0.24 0.35 300Pa 0.01 0.03 0.02 0.12 0.17 0.28 400Pa 0.08 0.11 0.22 500Pa 0.02 0.04 0.16 600Pa 0.09 700Pa 0.03 Sound pressure level (dB(A)@3m) 25 26 26 29 32 36 Max electrical power rating (W) 85 85 99 157 194 244 Weight (kg) 2.5 2.5 3.7 5 5.6 6.5 Guarantee (years, UK) 3 3 3 3 3 3

136 Controllers Dimensions (mm)

Inline Fan Controller XIC1 Remote Humidistat XRH XID Range Ref. 21858AW Ref. 21856AW • Slide switch provides fan On/Off control. • Stand alone humidistat switches fan On/Off Adjustable speed control for infinitely variable when RH reaches pre-set levels. Complete speeds. Complete with power ‘On’ with pullcord override switch indicator light Remote Time Controller DT20B Ref. 21850AW • User adjustable run on timer (2-20mins)

Passive Infrared Sensor XPIRA Ref. 21871AA • Activates fan via body movement. Ideal for Dimensions (mm) infrequently used public spaces Model ØA B C D • Built in timer to prevent nuisance tripping XID100 97 320 30 240 XID125 123 320 30 240 XID150 147 360 30 250 Typical Specifications on page 177. XID200 197 404 35 250 Wiring Diagrams on page 189. XID250 247 404 35 260 Control Details on pages 154-155. XID315 312 444 40 260

Performance s n a f e n i l n i l a t

Installation and Accessories e

EXTERNAL WALL m An extensive range of accessories are available l to complete the installation of the Xpelair XID a g

range of inline fans. u D f i r The installation diagram shows a typical XID A t

B n ducted installation and associated accessories. e C

A Flexible ducting | B Spigot plate D

C Wall duct I

D External air operated louvre shutter G X E C XID INLINE FAN r

E Grille box i

F Ceiling grille a l SUSPENDED CEILING

G Worm drive clip e

F p X 137 Xpelair XIDP Centrifugal plastic inline fans

Key features The Range

Type: Plastic inline Centrifugal inline fans provide the ideal The moulded casing is designed to ventilation solution for many exposed and provide the best possible bellmouth entry, Application: Commercial/Industrial high humidity applications. guide vanes and outlet. The wall thickness provides sound insulation and The Xpelair XIDP range is suitable for will not corrode. The case is both impact applications where the unit will be Control options: Speed control and and fire resistant and a mounting foot is seen – in wet areas such as kitchens, humidity/PIR sensing provided for fast and easy installation. shower areas and a wide range of commercial situations. The XIDP range is Available in six popular sizes the range is based on the proven XID external rotor compatible with Xpelair Xflex ducts and motor and impeller units to provide a ventilation components. range of high performance plastic inline fans.

Models

• Pressure developing, centrifugal inline • Insulation Class F. Fitted with safety fans suitable for extract or intake thermal overload protection - protected applications to IPX4 • Compact and robust polymer construction • Impeller is backward curved with integral terminal box and guide-vanes centrifugal type • Can be mounted at any angle using the • Supply voltage: 220-240V 50Hz universal mounting bracket supplied • External rotor motor - totally enclosed and lubricated for life

Impact and fire resistant casing

Select the right product for your application

XIDP100 XIDP125 XIDP150 XIDP200 XIDP250 XIDP315

Reference number 91383AA 91384AA 91385AA 91386AA 91387AA 91388AA Spigot diameter (mm) 99 124 149 199 249 314 Extract performance (m3/s) 0Pa 0.07 0.10 0.15 0.22 0.28 0.38 100Pa 0.05 0.08 0.11 0.18 0.24 0.33 200Pa 0.03 0.05 0.08 0.14 0.20 0.27 300Pa 0.01 0.01 0.03 0.11 0.15 0.21 400Pa 0.08 0.11 0.14 500Pa 0.03 0.06 0.09 600Pa 0.01 0.05 Sound pressure level (dB(A)@3m) 24 25 25 28 31 41 Max electrical power rating (W) 85 85 99 157 194 244 Weight (kg) 2.0 2.1 2.5 3.8 4.3 5.5 Guarantee (years, UK) 3 3 3 3 3 3

138 Controllers Dimensions (mm)

Inline Fan Controller XIC1 Remote Humidistat XRH XIDP Range Ref. 21858AW Ref. 21856AW • Slide switch provides fan On/Off control. • Stand alone humidistat switches fan On/Off Adjustable speed control for infinitely variable when RH reaches pre-set levels. Complete speeds. Complete with power ‘On’ with pullcord override switch indicator light Remote Time Controller DT20B Ref. 21850AW • User adjustable run on timer (2-20mins)

Passive Infrared Sensor XPIRA Ref. 21871AA • Activates fan via body movement. Ideal for Dimensions (mm) infrequently used public spaces. Built in timer Model ØA B C D to prevent nuisance tripping XIDP100 99 288 30 247 XIDP125 124 288 30 247 XIDP150 149 379 30 230 XIDP200 199 379 30 230 Typical Specifications on page 177. XIDP250 249 379 30 230 Wiring Diagrams on page 189. Control Details on pages 154-155. XIDP315 314 452 30 275

Performance s n a f e n i l n i c i t s a l

Installation and Accessories p

EXTERNAL WALL l An extensive range of accessories are available to a g complete the installation of the Xpelair XIDP range of u f inline fans. i D r t

The installation diagram shows a typical XIDP ducted n

A e installation and associated accessories. B C

A Flexible ducting | B Spigot plate C Wall duct P D

D External air operated louvre shutter I

G X E Grille box E C F Ceiling grille XIDP INLINE FAN r i

G Worm drive clip a l

SUSPENDED CEILING e

F p X 139 Xpelair XID & XIDP Centrifugal metal and plastic inline fans

Installation and Accessories

ACF

Xflex Flexible Ducting (3 metre lengths) FD • Complete with steel wire helix. Can be Egg Crate Ceiling Grille CG interlocked and sealed with duct tape to form Wall duct WD Length • Constructed from aluminium and can be an airtight seal used on ceilings or walls • For bridging cavities or lining solid exterior walls • Finished in satin silver. Also available in white • 100mm diameter FD100 (see page 144) Ref. 89663AA • 100mm duct diameter WD100 Ref. 89543AA • W200 x H200mm grille CG20 • 125mm diameter FD125 Ref. 89823AW Ref. 89664AA • 125mm duct diameter WD125 Ref. 89703AA • W300 x H300mm grille CG30 • 150mm diameter FD150 Ref. 89824AW Ref. 89665AA • 150mm duct diameter WD150 Ref. 89704AA • W450 x H450mm grille CG45 • 200mm diameter FD200 Ref. 89825AW Ref. 89666AA • 200mm duct diameter WD200 Ref. 89705AA • W500 x H500mm grille CG50 • 250mm diameter FD250 Ref. 89826AW Ref. 89667AA • 250mm duct diameter WD250 Ref. 89706AA • 315mm diameter FD315 Ref. 89668AA • 315mm duct diameter WD315 A Ref. 89707AA

D G

Ceiling Diffuser Grille DG • Aluminium construction and finished in white. Also available in satin silver (see page 144) Spigot Plate SP • W200 x H200mm grille DG20 Grille Box GB Ref. 89815AW • Fixes to inside of exterior wall • Used in conjunction with egg crate ceiling grille and ceiling diffuser grille to connect to • W300 x H300mm grille DG30 • 100mm spigot diameter SP100 ductwork Ref. 89817AW Ref. 89697AA • 100mm ducting diameter with 200 x 200mm • W450 x H450mm grille DG45 • 125mm spigot diameter SP125 grille GB20/100 Ref. 89819AW Ref. 89698AA Ref. 89676AA

• W500 x H500mm grille DG50 • 150mm spigot diameter SP150 • 125mm ducting diameter with 200 x 200mm Ref. 89821AW Ref. 89699AA grille GB20/125 Ref. 89677AA • W600 x H600mm grille DG60 • 200mm spigot diameter SP200 Ref. 90603AW Ref. 89700AA • 150mm ducting diameter with 200 x 200mm • 250mm spigot diameter SP250 grille GB20/150 Ref. 89701AA Ref. 89678AA B • 315mm spigot diameter SP315 • 200mm ducting diameter with 300 x 300mm Ref. 89702AA grille GB30/200 Ref. 89679AA

• 250mm ducting diameter with 300 x 300mm E grille GB30/250 Ref. 89680AA Air Operated Louvre Shutter XLG • External louvre shutter mounted to outside wall • 315mm ducting diameter with 450 x 450mm suitable for duct sizes grille GB45/315 Ref. 89681AA • 100mm diameter XLG100 Worm Drive Clips WDC Ref. 89691AA • For connecting lengths of flexible ductwork to • 315mm ducting diameter with 500 x 500mm spigots. Supplied in packs of 10 grille GB50/315 • 120mm diameter XLG125 Ref. 89828AA Ref. 89692AA • 100mm - 125mm diameter WDC5 Ref. 89684AA • 160mm diameter XLG150 • 315mm ducting diameter with 600 x 600mm Ref. 89693AA • 150mm – 200mm diameter WDC8 grille GB60/315 Ref. 89685AA Ref. 90296AA • W200 x H200mm XLG200 Ref. 89694AA • 250 mm – 315mm diameter WDC13 Ref. 89686AA • W250 x H250mm XLG250 Ref. 89695AA • W315 x H315mm XLG315 Ref. 89696AA

140 • • 250mmductdiameterCFC250 • • 150mmductdiameterCFC150 • 125mmductdiameterCFC125 • GSMconstructionand92%efficiencyrating • Filter BoxCFC Typical XIDorXIDPinlineductedinstallation Installation andAccessories Additional Accessories 400mm ductdiameterCFC400 315mm ductdiameterCFC315 200mm ductdiameterCFC200 Filter materialEU3 Ref. 90288AA Ref. 90287AA Ref. 90286AA Ref. 90285AA Ref Ref . . 90290AA 90289AA • • 200mmductdiameterSIL200 • • 125mmductdiameterSIL125 • 100mmductdiameterSIL100 • GSMconstructionwithleakfreespigots • Circular SilencerSIL 315mm ductdiameterSIL315 250mm ductdiameterSIL250 150mm ductdiameterSIL150 Ref Ref Ref. 89840AA Ref Ref. 89838AA Ref. 89837AA . . . 89842AA 89841AA 89839AA 315mmductdiameterXMK315 • 250mmductdiameterXMK250 • • • 125mmductdiameterXMK125 • • Suppliedinpairs • Antivibrationpropertiesthroughfoamlining • For connectingrigidducting • Solid DuctFastener XMK Ref. 89623AA Ref. 89622AA Ref Ref Ref. 89619AA Ref 200mm ductdiameterXMK200 150mm ductdiameterXMK150 100mm ductdiameterXMK100 . . . 89621AA 89620AA 89618AA 141

Xpelair XID & XIDP | Centrifugal metal and plastic inline fans Xpelair Xpress XPRS High pressure mixed flow inline duct fans NEW NEW

XPRS200 XPRS250 XPRS355

Key features The Range

Type: Mixed flow inline The New Xpelair Xpress range redefines an Xpress 250mm at 200Pa has a inline fan performance to provide ultra volume output double that of an high pressure development, volume and equivalent size centrifugal inline fan and Application: Commercial/Industrial efficiency allowing smaller ductwork to be 50% higher than 315mm. This impressive used than conventional inline fans. performance means that smaller ducts Control options: Speed control and can be chosen with an energy use lower At the heart of the design is a humidity/PIR sensing than most DC fans of the same dynamically balanced mixed flow impeller performance. Xpress is no bigger in and bellmouth entry with minimised diameter than the ductwork in which it is clearances to ensure optimum pressure mounted. No flanges are required; simply development. Transferred though a flexible connections. It comes with its own meridian channel, the air then enters a mounting foot which is factory fitted to static three dimensional guide vane. This eliminate on site assembly. And the new dihedral twist retains a third of the Xpelair Xpress can be run at any angle. pressure build up which would otherwise be lost. The air management is so Space saving, smaller ductwork, quieter efficient that air turbulence noise and and costing less to run, the technically vibration associated with centrifugal inline advanced Xpelair Xpress redefines inline fans is virtually eliminated. For example performance.

Models

• High pressure inline mixed flow fans • Matching aerofoil section guidevanes • Steel housing with bell mouth entry • Integral mounting foot (XPRS200 is plastic) • Terminal box to IP44 Cutaway of Xpress showing design of • Mixed flow fabricated blade and hub • Voltage speed controllable impellor and down stream guidevanes assembly balanced to G2.5 ISO 1940 • Continuously rated capacitor start and run motor with integrated thermal overload protection

Select the right product for your application

XPRS200 XPRS250 XPRS315 XPRS355/1 XPRS355/2

Reference number 92358AA 91498AA 91499AA 91500AA 91501AA Extract performance (m3/s) 0.42 0.47 0.96 0.71 1.38 Casing break out (dB(A)@3m) 47 35 43 32 50 Motor electrical power (W) 110 190 520 145 990 Electrical current FLC (A) 0.5 0.9 2.5 0.7 4.6 5 step transformer speed controller n/a 91367AA 31968AA 91367AA 91369AA Guarantee (years) 2 2 222 Fan rpm 2800 2890 2860 1460 2840 Weight (kg) 3.6 6.7 14.3 17.1 13.5

142 Controllers Installation and Accessories

5 Step Transformer Speed Controller Solid duct fastners XMK Filter box CFC 200 Ref. 89621AA 200 Ref. 90287AA • Multi-tapped auto transformer giving 5 speeds 250 Ref. 89622AA 250 Ref. 90288AA allowing accurate adjustment to suit site 315 Ref. 89623AA 315 Ref. 90289AA conditions • Provides five speed and On/Off function • Robust ISO casing • IPX4 protected

Backdraft shutter XBD Inline Duct Heater IDH 200 Ref. 89639AA 200 Ref. 90273AA 250 Ref. 89640AA 250 Ref. 90274AA 315 Ref. 89641AA 315 Ref. 90275AA

Typical Specifications on page 177. Control Details on pages 154. Domestic Accessories on page 158-159.

Performance s n a f

t c u d

e n i l n i

X PR

S w 35 5+ o l f

X X XP P P X R R R PR S d S S S 31 2 2 35 5 e 0 5 5 0 0 x i m

e r u s

Dimensions (mm) s e r p

A h g i

Dimensions (mm) H

Model A ØB |

XPRS200 225 200

XPRS250 280 250 S

ØB XPRS315 355 315 R

XPRS355/1 400 355 P

XPRS355/2 400 355 X

s s e r p X

r i a l e p X 143 Xpelair MinimX C XCDF Compact inline duct fans

Key features The Range

Type: Compact inline In many ducted systems ceiling space For ease of service inspection and can be severely restricted preventing the cleaning the motor/fan unit swings out on use of circular inline fans. The NEW a hinged access door. The precision Application: Commercial/Industrial Xpelair MinimX range of inline fans made housing has integrated mounting reduces the product height to a flanges with key hole ‘first-fit’ slots and an Control options: Speed control and minimum, providing system design accessible terminal box for fast assembly humidity/PIR sensing flexibility and easier installation. and wiring. Available to suit the six most popular duct A full range of Xpelair Ventilation sizes, the Xpelair MinimX range features accessories allow the design of a fully speed controllable two pole external complete system. rotor motors for use with matching speed Refer to pages 154-155. controllers and auto sensor control options available.

Models

• Pressure developing low profile inline fans with hinged ‘swing out’ door for periodic inspection/service access • Available in six performance diameters • Precision made, compact G.S.M construction • Integral mounting flanges with first-fit key hole slots • Continuously rated two pole external rotor motor/fan assemblies. Insulation Class F with thermal overload protection • Bearings lubricated for life • IP44 protection Integral keyhole fixings for • Terminal box with knock outs and one fast and easy installation cable entry gland rated IP44

Select the right product for your application

XCDF100 XCDF125 XCDF150 XCDF200 XCDF250 XCDF315

Reference number 91502AA 91503AA 91504AA 91505AA 91506AA 91507AA Extract performance (m3/s) 0.08 0.084 0.09 0.17 0.27 0.43 Sound power level (dB(A)@3m) 35 41 42 47 541 51 Breakout (dB(A)@3m) 29 29 29 32 37 39 Motor electrical power (W) 90 95 95 95 190 290 Electrical current SC (A) 0.5 0.5 0.5 0.5 0.9 1.3 5 step transformer speed controller 91367AA 91367AA 91367AA 91367AA 91367AA 91367AA Electronic speed controller 89903AA 89903AA 89903AA 89903AA 89903AA 89904AA Guarantee (years) 2 2 2 2 2 2

144 Controllers

Remote Humidistat XRH Remote Time Controller DT20B Passive Infrared Sensor XPIRA Ref. 21856AW Ref. 21850AW Ref. 21871AA • Stand alone humidistat switches fan On/Off • User adjustable run on timer (2-20mins) • Activates fan via body movement. Ideal for when RH reaches pre-set levels. Complete infrequently used public spaces. Built in timer with pullcord override switch to prevent nuisance tripping

Typical Specifications on page 178. Details of Controls/Sensors on page 155.

Performance s n a f

t c u d

Dimensions (mm) e n i l n i

Dimensions (mm) t

Model ØA B C D E F G H I c

XCDF100 100 300 324 348 350 248 72 170 110 a

XCDF125 125 300 324 348 350 248 79 170 98 p

XCDF150 150 300 324 348 364 248 89 170 85 m

XCDF200 200 400 424 448 479 350 115 230 115 o XCDF250 250 400 424 448 478 350 141 280 140 C XCDF315 315 400 424 448 478 400 174 345 173 |

F

Installation and Accessories D C X

C A Louvred wall shutter XLG D C

A B Wall duct WD X C Spigot plate SP m

D Xflex ducting i

E Grille box GB n i F Egg-crate grille CG M

B r E XCDF INLINE FAN i F a l e p X 145 Xpelair LoSound C LQTC Attenuated inline fans

Key features The Range

Type: Attenuated inline The Xpelair LoSound range of attenuated All models can be installed with the inline fans consists of six models for use covers upwards or inverted. in ducted applications where high Application: Commercial/Industrial The Xpelair LoSound range is suitable for performance and low sound levels are ambient temperatures up to 40ºC. required. Suitable for commercial and Control options: Speed control and industrial applications such as schools, Optional speed controller is available. humidity/PIR sensing shops, offices, pubs and restaurants, the compact design allows easy installation above suspended ceilings or floor voids using the mounting points provided. The high performance, low noise level motor combined with a cabinet lined on four sides with 40mm sound absorbent material makes LoSound range particularly suitable where low sound operating levels are necessary.

Models

• Galvanised sheet metal casing with • The IP44 capacitor start and run motor is integral keyhole fixing points rated for continuous running • The casing is lined on four sides with • Class B motor 40mm faced attenuation material • The unit is provided with a removable • A 3m three core flexible cord is provided cover with quick release catches for with the unit periodic inspection and cleaning • External rotor motor and forward curved centrifugal fan assembly dynamically balanced in two planes. The motor is maintenance free with sealed for life bearings, and integral thermal overload protection

Select the right product for your application

LQTC125 LQTC150 LQTC200 LQTC250 LQTC315 LQTC355 Reference number 91989AA 91990AA 91991AA 91992AA 91993AA 91994AA Extract performance (m3/s) 0.10 0.11 0.21 0.31 0.48 0.69 Sound pressure level (dB(A)@3m) 31 32 39 39 42 48 Sound breakout (dB(A)@3m) 27 27 30 22 32 41 Motor electrical power (W) 100 100 165 275 550 880 Electrical current SC (A) 0.5 0.5 0.8 1.3 2.5 4.2 5 step transformer speed controller 91367AA 91367AA 91367AA 91367AA 91368AA 91369AA Guarantee (years) 22 2 2 22

146 Controllers

5 Step Transformer Speed Controller TI-1.5A Ref.91367AA • Multi-tapped auto transformer giving 5 speeds allowing accurate adjustment to suit TI-3.5A site conditions Ref.91368AA • Provides five speed and On/Off function • Robust ISO casing TI-6A • IPX4 protected Ref.91369AA

Typical Specifications on page 178.

Performance s n a f

e n i l n i

d e t a

Dimensions (mm) u n e t t

Dimensions (mm) A

Model ØA B C D E F G H I J |

LQTC125 125 400 406 448 464 365 368 247 126 154 LQTC150 150 400 406 448 464 365 368 247 126 154 C LQTC200 200 400 406 448 486 365 368 306 183 174 LQTC250 250 400 406 448 494 468 471 322 234 173 T

LQTC315 315 450 456 498 528 540 543 397 270 206 Q

LQTC355 355 600 606 648 678 600 603 467 236 268 L

C

Installation and Accessories d n An extensive range of accessories are Xflex FD u available to complete the installation of the Worm drive clips WDC o Xpelair LoSound C Range of inline Grille box GB S centrifugal fans. Egg crate ceiling grille CG Ceiling diffuser grille DC o

Circular silencer SIL L Inline duct heater IDH r

Air operated louvre shutter XLG i

Spigot plate SP a

Wall duct WD l

Flexible connector FCC e

For details refer to pages 156-159. p X 147 Xpelair CubeX CMAX CBXC Versatile attenuated inline fans

Key features The Range

Type: Versatile Where higher general ventilation duties Each model is available with a choice of attenuated inline are required the new Xpelair CubeX two spigot sizes to suit duct design. range provides a flexible solution The range is available in four sizes with a designed with a choice of duct sizes. Application: Commercial/Industrial choice of two spigot sizes for each Installed in offices, commercial buildings, ranging from 315mm to 450mm. public areas, the leisure industry and Control options: Speed control and A full range of Xpelair ventilation industrial applications. humidity/PIR sensing accessories is available. Xpelair CubeX models combine high performance backward curved centrifugal inline fans with sound attenuation and robust steel housings.

Models

• Backward curved centrifugal impeller and • Galvanised double skin casing with 40mm external rotor motor assembly with insulation maintenance free long life bearings • Includes condensation drain facility • Thermal contacts connected to terminals • 220- 240V single phase • Full motor protection through external tripping device • Rigid frameless sheet metal construction

CubeX spigot options

Select the right product for your application

CBXC280S315 CBXC280S355 CBXC315S315 CBXC315S355 CBXC355S315 CBXC355S355 CBXC400S400 CBXC400S450

Reference number 91508AA 91509AA 91510AA 91512AA 91513AA 91514AA 91515AA 91516AA Spigot size (mm) 315 355 315 355 315 355 400 450 Extract performance (m3/s) 0.70 0.74 0.98 1.01 0.65 0.68 1.11 1.13 Sound pressure level (dB(A)@3m) 58 58 64 64 51 51 55 55 Max electrical power rating (W) 660 680 950 920 280 280 570 560 Electrical current SC (A) 3.5 4.0 4.9 4.8 1.4 1.4 3.2 3.2 Electrical current FLC 3.2 3.3 4.2 4.1 1.3 1.3 3.0 3.1 (dB(A)@3m) 43 43 n/a n/a n/a n/a n/a n/a 5 step transformer speed controller 91369AA 91369AA 91369AA 91369AA 91367AA 91367AA 91368AA 91368AA Guarantee (years) 2 2 2 2 2 2 2 2 Insulation Class F nnnnnnnn

148 Controllers Installation and Accessories Typical Specifications on page 178. Remote Sensors on page 154. Full Range of Ancillaries 5 Step Transformer Speed Controller An extensive range of accessories are available on pages 158-159. to complete the installation of the Xpelair CubeX • Multi-tapped auto transformer giving 5 speeds allowing accurate adjustment to suit CMAX Range of inline centrifugal fans. site conditions • Provides five speed and On/Off function • Robust ISO casing Solid duct fastener XMK • IPX4 protected Backdraft shutter XBD Filterbox CFC Xflex ALU

Performance

Volume (C.M.F.)

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 s n a

1200 f

e n i l n

1000 i

d e t

800 a u ] n a CBXC P 280 [ e

e t r t u s

s 600 a e r

P

c i e t C

B l a X t

C i

S 3 15 t

400 a s r e C BX V C400

200 CB | XC35 5

C

0 X

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 B

Airflow [m3/s] C

Dimensions (mm) X A

Dimensions (mm) M Model A BCØD C CBXC280S315 500 500 500 315 CBXC280S355 500 500 500 355 X CBXC315S315 500 500 500 315 e CBXC315S355 500 500 500 355 b u CBXC355S315 500 500 500 315 C

CBXC355S355 500 500 500 355 r

CBXC400S400 700 700 700 400 i

CBXC400S450 700 700 700 450 a l e p X 149 Xpelair HiFlo CMAX XSFA Attenuated inline fans

Key features The Range

Type: Attenuated inline The Xpelair HiFlo XSFA range of attenuated The high performance, low noise level inline fans is a nine model line up of fans for motor, combined with a cabinet lined with use in ducting applications where high fire rated sound absorbing material makes Application: Commercial/Industrial performance and low sound levels are XSFA units particularly suitable where low required. sound operating levels are critical. Control options: Electronic/Transformer speed control Suitable for light commercial and industrial All models can be mounted with the cover applications such as schools, shops, sports upwards or inverted. complexes, offices, pubs and restaurants, The HiFlo range is suitable for ambient the compact design of the range allows the temperatures from –30°C to +50°C and an fans to easily be accommodated above a optional range of speed controllers and suspended ceiling or floor void using the sensors are available. mounting points provided.

Models

• High performance pressure developing • Continuously rated capacitor start and run inline fan suitable for extract or input motor with sealed for life bearings and applications using circular ductwork safety thermal overload protection • Fan housing manufactured in G.S.M with • Metal impeller balanced to acoustic sound absorbing material to ISO 1940 – 1 : 1986 grade G 6.3 Class 0 fire rated to BS 476 parts 6 and 7 • IP54 terminal box to minimise noise break-out • Fans are easily disconnected from a • 50mm deep connection spigots mounting plate for cleaning • Insulation class B & F • Integral fixing slots (23 x 11mm) on each • Motors - Direct drive, double inlet, forward side of cabinet Select the right product for your application curved centrifugal fan / scroll assembly • Supply voltage: 220-240V 50Hz

XSFA100 XSFA125 XSFA150 XSFA200 XSFA250 XSFA315/1 XSFA315/2 XSFA400/1 XSFA400/2

Reference number 91389AA 91390AA 91391AA 91392AA 91393AA 91394AA 91395AA 91396AA 91397AA Spigot diameter (mm) 100 125 150 200 250 315 315 400 400 Extract performance (m3/s) 0Pa 0.07 0.13 0.19 0.24 0.54 0.56 0.70 0.72 1.05 50Pa 0.07 0.12 0.19 0.23 0.51 0.53 0.68 0.70 1.02 100Pa 0.06 0.12 0.18 0.21 0.46 0.49 0.66 0.68 0.99 150Pa 0.06 0.11 0.17 0.19 0.40 0.43 0.64 0.66 0.95 200Pa 0.05 0.11 0.16 0.18 0.30 0.33 0.60 0.62 0.91 250Pa 0.05 0.10 0.14 0.15 0.03 0.03 0.56 0.58 0.85 300Pa 0.04 0.08 0.11 0.12 0.47 0.48 0.75 350Pa 0.05 0.07 0.07 0.17 0.17 0.58 400Pa 0.00 0.01 0.01 0.01 Nominal fan speed (rpm) 2150 1150 1150 1150 1300 1300 1100 1100 1210 Sound pressure level (dB(A)@3m) 41 32 33 34 40 41 42 44 51 Motor electrical power (W) 88 195 195 195 360 360 700 700 1240 Electrical current FLC (A) 0.4 1 1 1 1.6 1.6 3 3 6 Electrical current SC (A) 1 3 3 3 4.5 4.5 7.5 7.5 16 Motor insulation class B B B B F F B B F Weight (kg) 14 14 15 15 26 32 35 40 45 5 step transformer speed controller 91376AA 91367AA 91367AA 91367AA 91368AA 91368AA 91368AA 91368AA 91370AA Guarantee (years, UK) 222 22 2 2 2 2

150 Controllers Dimensions (mm)

Inline Fan Controller XIC1 5 Step Transformer Speed Controller Ref. 21858AW • Multi-tapped auto transformer giving 5 • Slide switch provides On/Off control. speeds allowing accurate adjustment to suit Adjustable speed control for infinitely variable site conditions speeds. Complete with power ‘On’ • Provides five speed and On/Off function indicator light • Robust ISO casing • IPX4 protected

Typical Specifications on page 179. Remote Sensors on pages 154.

Dimensions (mm) Model A B C ØD XSFA100 450 515 250 100 XSFA125 450 515 250 125 XSFA150 450 515 250 150 XSFA200 450 515 250 200 XSFA250 600 915 450 250 XSFA315/1 600 915 450 315 XSFA315/2 600 915 450 315 XSFA400/1 600 915 450 400 XSFA400/2 600 915 450 400

Performance

Volume (C.M.F.)

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 s n a f

400 e n i l

350 n i

d

300 e t a ] a u

P 250 [

n e r e u t s t s 200 e r

X A P

S c F i X t A S a 4 150 | t 0 F

A S 0 / 4 1 0 0 X A / X S X 2 100 X S F S X X X F A F S F S A S S 3

F 2 A F 1 F F 5 A 5 3 S A A A 0 1 1 / 1 1 2 1 5 0 2 5 0 / X 50 0 5 0 0 2

X 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 A M Airflow [m3/s] C

o

Installation l F i H

r i a l e p X 151 Xpelair ManCoolers Commercial and industrial cooling fans NEW NEW

ManCooler Trapeze

Key features The Range

Type: Air re-circulation With more unpredictable fluctuations in our Xpelair ManCoolers can fulfil a wide weather the need for temporary solutions range of duties in industry and the public Application: Commercial/Industrial to deal with temperature extremes has sector. An effective and reliable answer never been more relevant. Xpelair portable where even large quantities of air are Building sites ManCoolers are an ideal spot cooling required quickly, the ManCooler range solution. comes complete with their own robust stand and are easy and quick to set up. The ManCooler range of commercial and The adjust-and-lock head allows the units industrial air coolers are ideal for use in to be tilted for maximum benefit. areas such as factory assembly lines, steelworks, factory moulding areas, For more permanent applications, or where hospitality marquees, and general floor space is at a premium the Xpelair movement applications in large areas. Trapeze model is ideal for suspension at high level. Trapeze units are also ideal for The range has also been designed to be reaching unventilated corners of otherwise used for drying outbuildings and still air on large sites. Or forcing hot air to equipment after flood damage. ground level.

Select the right product for your application

ManCooler Trapeze MC350 MC400 MC400 110V MC450 MC560 TP450

Reference number 91408AA 91409AA 92309AA 91410AA 91411AA 91412AA Fan diameter (mm) 355 410 410 460 560 460 Extract performance (FID, m3/s) 0.86 1.42 1.42 1.97 3.06 1.44 Nominal fan speed (rpm) 1440 1450 1380 1375 1375 950 Sound pressure level (dB(A)@3m) 59 64 64 68 72 57 Voltage (V) 230 230 110 230 230 230 Electrical power rating (W) 120 250 550 370 550 250 Electrical current FLC (A) 0.67 1.90 4.60 3.10 4.40 1.50 Weight (kg) 12 19 19 22 27 14 Guarantee (years, UK) 1 1 1111

152 Models

ManCooler Trapeze MC350 Ref. 91408AA TP450 Ref. 91412AA MC400 Ref. 91409AA • Suspended air circulation unit MC400 110V Ref. 92309AA • 460mm fan diameter MC450 Ref. 91410AA • For horizontal or vertical suspension MC560 Ref. 91411AA • The distance of the fan to the floor should be • Portable commercial cooling fans in no less than 2700mm four sizes • Stainless steel construction • Powder coated fan housing • Continuously rated totally enclosed • Angle adjustable and lock maintenance free motor with sealed for • Tubular steel frame life bearings • Safety finger guards to DIN 24167 • Protected to IP55 (UNE 20-359-74) fitted inlet and outlet • IP55 connection box • Continuously rated totally enclosed • Four suspension eyes maintenance free motor with sealed for • Suitable for ambient temperature up to 40ºC life bearings IP55 • Supply voltage: 220-240V 50Hz • IP55 connection box with On/Off switch • Suitable for ambient temperatures up to 40ºC • Supply voltage: 220-240V 50Hz Typical Specifications on page 179. 110V - MC 400 110V

Performance s n

ManCooler MC350 ManCooler MC400 a f

g n i l o o c

l a i r t

ManCooler MC450 ManCooler MC560 s u d n i

d n a

l a i c r e Dimensions (mm) m m

ManCooler Trapeze o C

Dimensions (mm) |

Model A B C D E F

MC350 415 489 736 420 230 355 s MC400 450 596 775 481 320 410 r e

MC400 450 596 775 481 320 410 l

110V o

MC450 453 596 795 481 360 460 o

MC560 522 726 945 594 400 560 C n a M

r i a l e p X 153 Xpelair Industrial Controllers & Accessories

Electronic Speed Controller SXCW Inline Fan Controller XIC1 5 Step Transformer Speed Controller T1/T3 1AMP XCW1.1 Ref. 89903AA Ref. 21858AW Single phase 3AMP XCW1.3 Ref. 89904AA T1 - 1.5A Ref. 91367AA IP54 6AMP XCW1.6 Ref. 90408AA • Suitable for use with all models. T1 - 3.5A Ref. 91368AA IP54 • Slide switch provides: On/Off T1 - 6A Ref. 91369AA IP54 • Adjustable control for infinitely • Electronic speed control T1 - 7.5A Ref. 91370AA IP54 variable speed • Provides On/Off and infinitely variable T1 - 12A Ref. 91371AA IP21 speed control • Power ‘On' indicator light 3 phase • Fan operation indicator light • Surface or recess mounting T3 - 1A Ref. 91361AA IP54 • Surface or recess mounting • Colour: white • w160 x h86mm • w160 x h86mm T3 - 2A Ref. 91362AA IP54 T3 - 3A Ref. 91363AA IP54 T3 - 5.2 Ref. 91364AA IP54 T3 - 7A Ref. 91365AA IP21 T3 - 14A Ref. 91366AA IP21

• In single and 3 phase suitable for speed control of all speed controllable fans • Robust light grey ISO sealed casing • Rotary switch • Fully impregnated transformer ISO class II, T40 E conforms to VDE 0550 • Max. ambient Temp. +40ºC • Automatic reconnection after mains failure • Integrated status signal lamp • Surface mounting

Dimensions of 5 Step Auto Transformers

Dimensions (mm) Model A B C T1 - 1.5A 105 180 98 T1 - 3.5A 166 230 118 T1 - 6A 166 230 118 T1 - 7.5A 240 284 131 T1 - 12A 270 323 163 T3 - 1A 240 284 131 T3 - 2A 240 284 131 T3 - 3A 270 323 163 T3 - 5.2 270 323 163 T3 - 7A 270 323 163 T3 - 14A 450 290 174

154 Starter and Thermal Overload Protection STP Remote Humidistat XRH Time Delay Controller DT20B STP1 Single phase 0.4 - 10A Ref. 91372AA Ref. 21856AW Ref. 21850AW STP3 3 phase 0.1 - 25A Ref. 91373AA • Stand alone humidistat switches On • Usually connected to the lighting circuit. • For single phase fans with thermal contact when RH rises to preset level and Off Fan switches On with the light. Provides leads wired to a terminal block and single when it declines continued ventilation run-on period after speed three phase fans with thermal contacts. • Fan operation indicator the light has been switched Off Used with motors of higher performance • Pullcord operated override switch • User adjustable up to 20min where the thermal contacts or PTC thermistors • Surface or recess mounting • Surface or recess mounting are wired to the terminal block and must be • White finish • White finish connected to a motor protection device • Supply voltage 220-240V 50Hz • Supply voltage 220-240V 50Hz • On/Off push button operations. Manual • w160 x h86 x d41mm • w100 x h86 x d45mm reset after failure (not after power loss) • Amp inductive load 2A @ 240V AC • Delay timer period 30 secs - 20 mins • Volts free contact for connection of alarm • Amp inductive load 2.5A @ 240V AC • IP55 enclosure • Surface mounting • w80 x h150 x d98mm

s e i r o s s e c c A

&

s r e l

Passive Infrared Sensor XPIRA Air Quality Sensor AQS l

Ref. 21871AA Ref. 92097AW o r

• For indoor use • Provides fully automatic control t • Automatically switches a fan on when • Detects contaminants such as cigarette n body movement is detected smoke, body odours, toilet odours and o

• Incorporates a delay timer details cooking smells C

• Supply voltage 220-240V 50Hz • Activates ventilation system when preset l

• Used with: Premier DX200, DX400, DX100, threshold level is exceeded a CMF, CX10, GX6 • Can control up to six fans and accessories i r

• w86 x h86mm • Integral timer adjustable from 3 - 30 mins t

• Amp inductive load 2A @ 230V AC 50/60Hz • LED status indicator s

• Surface or recess mounting u

• Supply voltage 220-240V 50Hz d • w160 x h86 x d41mm n

• Amp inductive load 3A @ 240V AC I

• Alarm connection has maximum inductive r load of 0.3A @240V AC i a l e p X www.xpelair.co.uk 155 Xpelair Industrial Controllers & Accessories

External Louvre Grilles EG Air Operated Louvre Shutters XLS Air Operated Louvre Shutters XLG Duct size Duct size Hole diameter EG30 300x300mm Ref. 89534AA XLS315 315x315mm Ref. 89905AA XLG100 100mm dia Ref. 89691AA EG45 450x450mm Ref. 89535AA XLS350 350x350mm Ref. 91144AA XLG125 120mm dia Ref. 89692AA EG50 500x500mm Ref. 90538AA XLS400 400x400mm Ref. 89906AA XLG150 160mm dia Ref. 89693AA EG67 670x670mm Ref. 90539AA XLS450 450x450mm Ref. 89907AA XLG200 200x200mm Ref. 89694AA XLS500 500x500mm Ref. 90540AA XLG250 250x250mm Ref. 89695AA • Weather resistant recess mounting XLS670 670x670mm Ref. 90541AA XLG315 315x315mm Ref. 89696AA fixed louvre grille for exterior walls XLG400 400x400mm Ref. 90294AA • Aluminium construction • Aluminium construction • Fitted birdguard • Fixed to outside of exterior wall • Plastic construction • Air operated • Fixed to outside of exterior wall • Use with: XPM • Air operated • Colour: white

Egg-Crate Ceiling Grilles CG Ceiling Diffuser Grilles DG Air Volume Dampers AVD Duct size SATIN SILVER Duct size SATIN SILVER Square CG20 200mm Ref. 89675AA DG20 200mm Ref. 89816AA AVD20 200mm Ref. 89829AA CG30 300mm Ref. 89532AA DG30 300mm Ref. 89818AA AVD30 300mm Ref. 89830AA CG45 450mm Ref. 89533AA DG45 450mm Ref. 89820AA AVD45 450mm Ref. 89831AA CG50 500mm Ref. 89827AA DG50 500mm Ref. 89822AA AVD50 500mm Ref. 89832AA CG60 600mm Ref. 90295AA DG60 600mm Ref. 90292AA • Clips directly to an eggcrate grille or Square WHITE Square WHITE ceiling diffuser grille to adjust the volume CG20 200mm Ref. 89823AW DG20 200mm Ref. 89815AW of air entering or leaving the room • Lever adjustment CG30 300mm Ref. 89824AW DG30 300mm Ref. 89817AW • Depth 44mm CG45 450mm Ref. 89825AW DG45 450mm Ref. 89819AW • Used together with Grille Box and DG50 500mm Ref. 89821AW CG50 500mm Ref. 89826AW Xflex ducting DG60 600mm Ref. 90603AW • Material: Aluminium Mill finish • Can be used on ceilings or internal walls as an extract grille with large free area • For air input systems terminating at • Aluminium construction ceilings and internal walls • Fixing screws provided (not size 600) • Adjustable grille vanes to set up • Use will grille boxes and Xflex ducting direction of airflow for a particular area • Colours: Satin silver or white • Fixing screws provided (not size 600) • Use with grille boxes and Xflex ducting • Aluminium construction • Colours: Satin Silver or White

156 Grille Box GB Four Way Ceiling Diffusers FW Spigot Plate/Damper FWS Duct Dia Square To fit square Diffuser Spigot GB20/100 100mm 200mm Ref. 89676AA duct size Square Dia GB20/125 125mm 200mm Ref. 89677AA FW225 225x225mm Ref. 91424AA FWS150 225mm 150mm Ref. 91430AA GB20/150 150mm 200mm Ref. 89678AA - - - FWS200 225mm 200mm Ref. 91431AA GB30/200 200mm 300mm Ref. 89679AA GB30/250 250mm 300mm Ref. 89680AA FW300 300x300mm Ref. 91425AA FWS250 300mm 250mm Ref. 91432AA GB45/315 315mm 450mm Ref. 89681AA FW350 350x350mm Ref. 91426AA FWS300 350mm 300mm Ref. 91456AA GB50/315 315mm 500mm Ref. 89828AA FW400 400x400mm Ref. 91427AA FWS400 400mm 400mm Ref. 91433AA GB60/315 315mm 600mm Ref. 90296AA FW450 450x450mm Ref. 91428AA FWS450 450mm 400mm Ref. 91434AA FW500 500x500mm* Ref. 91429AA - - - - • Used in conjunction with egg-crate ceiling grille and ceiling diffuser grille to connect *outer frame dim. 600x600 to ductwork • Rigid lightweight polypropylene frame • Interlock with four way diffusers • Use Xflex FD or TFD to attach to spigot • Four drop-in diffuser cassette can be set • Sloping spigot and barbs for easy duct and secure with worm drive dip up for angled or downward diffusion attachment • Grille box depth 97mm • Each cassette can be fitted eight ways • Built-in air volume damper in spigot sizes • Flange size 18mm providing multi directional air patterns up to 300mm • Secret fixings adjust to varying plasterboard and tile thickness without surface screws • Largest size drops into 600x600 mm ceiling grid system

s e i r o s s e c c A

&

s r e l

Wall Mounting Bracket WMB Short Case Axial Fan Xtras SCX Flexible Connection FCC l Fan size Ref. 90310AA Duct dia o SCX315 (XSCA315) Ref. 91317AA FCC1 125mm Ref. 90297AA r SCX350 (XSCA350) Ref. 91318AA t • Strong G.S.M construction FCC2 150mm Ref. 90298AA n • Sold in pairs SCX400 (XSCA400) Ref. 91319AA

FCC3 200mm Ref. 90299AA o • For use with XSFA SCX450 (XSCA450) Ref. 91320AA

SCX500 (XSCA500) Ref. 91321AA FCC4 250mm Ref. 90300AA C

SCX560 (XSCA560) Ref. 91322AA FCC5 315mm Ref. 90301AA l

FCC6 400mm Ref. 90302AA a • Installation pack comprising of: i r

2 steel matching coupling flanges • For reduction of vibration in a t

2 flexible connectors ducting system s

4 worm drive clips • 150mm length u

2 mounting feet • Neoprene rubber collar stitched to female d 4 anti-vibration mounts metal bands n I

r i a l e p X www.xpelair.co.uk 157 Xpelair Industrial Controllers & Accessories

Flexible Ducting Xflex FD New Aluminium Flexible Ducting Xflex ALU Thermal Flexible Ducting Xflex TFD Dia Length Dia Length Dia Length FD100 100mm 3m Ref. 89663AA ALU100 100mm 10m Ref. 91435AA TFD100 100mm 5m Ref. 89847AA 6m Ref. 89669AA ALU125 125mm 10m Ref. 91436AA 10m Ref. 91459AA FD125 125mm 3m Ref. 89664AA ALU150 150mm 10m Ref. 91437AA TFD125 125mm 5m Ref. 89848AA 6m Ref. 89670AA ALU200 200mm 10m Ref. 91438AA 10m Ref. 91460AA FD150 150mm 3m Ref. 89665AA ALU250 250mm 10m Ref. 91439AA TFD150 150mm 5m Ref. 89849AA 6m Ref. 89671AA ALU315 315mm 10m Ref. 91440AA 10m Ref. 91461AA FD200 200mm 3m Ref. 89666AA ALU400 400mm 10m Ref. 91441AA TFD200 200mm 5m Ref. 89850AA 6m Ref. 89672AA 10m Ref. 91462AA FD250 250mm 3m Ref. 89667AA • Tough aluminium foil construction on a high TFD250 250mm 5m Ref. 89851AA 6m Ref. 89673AA strength wire helix 10m Ref. 91463AA FD315 315mm 3m Ref. 89668AA • Over 40 minute fire rating BS 476: TFD315 315mm 5m Ref. 89852AA 6m Ref. 89674AA Part 20 (1987) 10m Ref. 91464AA • Can be interlocked and sealed with duct • Glass fibre fabric on a PVC coated close tape to form an airtight seal • Double skinned insulated aluminium pitch steel wire helix. 54 minute fire • Attached to spigots using worm drive clips duct with high density fibreglass integrity from within as measured to BS insulation to minimise condensation 476: Part 20 - (1987) formulation • Can be interlocked and sealed with duct • 25 minute fire integrity from within as tape to form an airtight seal measured to BS 476: Part 20 - (1987) • Attached to spigots using worm drive clips • Can be interlocked and sealed with duct tape to form an airtight seal • Attached to spigots using worm drive clips

Solid Duct Fasteners XMK Y Piece Splitters YPS Backdraught Shutters XBD Duct dia Duct dia Duct dia XMK100 100mm Ref. 89618AA YPS1 100x100x100mm Ref. 91281AA XBD100 100mm Ref. 89636AA XMK125 125mm Ref. 89619AA YPS13 100x100x125mm Ref. 92243AA XBD125 125mm Ref. 89637AA XMK150 150mm Ref. 89620AA YPS2 100x100x150mm Ref. 91282AA XBD150 150mm Ref. 89638AA XMK200 200mm Ref. 89621AA YPS3 125x125x125mm Ref. 91283AA XBD200 200mm Ref. 89639AA XMK250 250mm Ref. 89622AA YPS4 125x125x150mm Ref. 91284AA XBD250 250mm Ref. 89640AA XMK315 315mm Ref. 89623AA YPS5 150x150x150mm Ref. 91285AA XBD315 315mm Ref. 89641AA XMK400 400mm Ref. 90293AA YPS6 150x150x200mm Ref. 91286AA XBD500 500mm Ref. 90535AA YPS7 200x200x200mm Ref. 91287AA • For connecting XID and XIDP fans to rigid YPS8 200x200x250mm Ref. 91288AA • G.S.M construction ductwork YPS9 200x200x300mm Ref. 91289AA • Spring loaded flaps • Supplied in pairs • For use with XID, XIDP and cabinet fans YPS10 250x250x250mm Ref. 91290AA • Metal clamping band with vibration • Fits between two lengths of ducting absorbent foam YPS11 250x250x300mm Ref. 91291AA which are secured to the outside with YPS12 300x300x300mm Ref. 91292AA worm drive clips when using Xflex FD ducting or with solid duct fasteners for • Fire retardant ABS moulded splitters solid ducting • Leading lip for improved fixing to flexible ducting • Space saving two component construction

158 Circular Silencers SIL Inline Electric Duct Heaters IDH Bag Filter Cassettes CFC Duct dia Length Dia Watts Airflow Dia Duct dia Box square (mm) (mm) (mm) (m3/s) (mm) CFC125 125mm 155mm Ref. 90285AA SIL100 100 300 200 Ref. 89837AA IDH1 750 0.02 100 Ref. 90270AA CFC150 150mm 180mm Ref. 90286AA SIL125 125 300 225 Ref. 89838AA IDH2 1000 0.03 125 Ref. 90271AA CFC200 200mm 230mm Ref. 90287AA SIL150 150 300 250 Ref. 89839AA IDH3 1500 0.04 150 Ref. 90272AA CFC250 250mm 280mm Ref. 90288AA SIL200 200 300 300 Ref. 89840AA IDH4 2000 0.08 200 Ref. 90273AA CFC315 315mm 345mm Ref. 90289AA SIL250 250 300 350 Ref. 89841AA IDH5 3000 0.12 250 Ref. 90274AA CFC400 400mm 430mm Ref. 90290AA SIL315 315 300 415 Ref. 89842AA IDH6 4500 0.24 315 Ref. 90275AA IDH7 9000 0.31 400 Ref. 90276AA • G.S.M construction • Simple but effective inline filtration • For use with all circular duct systems IDH8 18000 0.49 500 Ref. 90277AA • For rigid ductwork the spigot • Filter medium EU3 • 92% efficient to BS 2831 number 2 test incorporates a duct seal for leak free • Built in manual reset thermal cutout for • All filter boxes are 130mm deep construction added safety • Lid secured by screw on 2 sides • G.S.M construction. • G.S.M sleeve • For use with rigid or flexible ductwork • Connection box on top of unit • Sheathed heating element • All duct heaters 400mm long • Duct heater height equals dia + 46mm • On/Off operation • Suitable for 240V/IPH/50Hz Electrical supply

Must be controlled via a suitable fan electric control

device complete with thermal overload protection and s

run-on-timer. To eliminate any possibility of fire especially e

when fan speed controllers are used. i r o s

NEW NEW s e c c A

&

s r

Circular Air Valves CAV Circular Air Valve with Fire Damper Worm Drive Clips WDC e l

Dia Dia • For connecting lengths of flexible ductwork l

CAV100 100mm Ref. 89682AA CAV125FD 125mm Ref. 91495AA to spigots. Supplied in packs of 10 o • 100mm - 125mm diameter WDC5 r

CAV125 125mm Ref. 91490AA • Valve includes built in fire damper for use t CAV150 150mm Ref. 89683AA in kitchens Ref. 89684AA n • Valve has adjustable centre disc • Valve has adjustable centre disc and can be • 150mm – 200mm diameter WDC8 o • Multi inlets/outlets for XID100, XID125 and used as outlet for XID125 and Xplus Ref. 89685AA

• 250 mm – 315mm diameter WDC13 C

XID150 • Tested to BS476 Part 20 - provides 1 hour

Ref. 89686AA l • Flexible ducting (FD) can be terminated at fire check

the valve a i r t s u d n I

r i a l e p X www.xpelair.co.uk 159

Xpelair Typical Specification

Xpelair Premier DX180, DX200 & CF20

The unit is to be supplied from the Xpelair • CF20 models shall be supplied with • The unit shall be suitable for zone 1 and Premier range by Applied Energy Products Ltd, outside grille zone 2 requirements as defined by IEE Morley Way, Peterborough PE2 9JJ Wiring Regulations 16th Edition BS 7674:2001 • DX200 models shall have selectable speed Tel. +44 (0)1733 456789 running facility with speed selection at • A rectangular cut out section shall be installation provided in the top of the fan housing to • DX200T shall have an adjustable overrun connect to Xpelair Profile kit Ref. 90547AA Model Ref timer (30s - 20min) with 2min start delay • The housing and stylish air inlet shall be DX180* 91181AW • CF20 shall have automatic operation through moulded in high gloss white ABS integral humidity sensor, manual boost speed DX180T* 91182AW • The front cover shall be held in position via pullcord and trickle ventilation DX180H* 91183AW by the retaining clips to facilitate removal • CF20T shall have automatic operation and adjustment DX200 91013AW through integral humidity sensor, manual • The motor shall be totally enclosed, fitted DX200T 91014AW boost speed via pullcord and trickle ventilation. Adjustable overrun timer with sealed self aligning maintenance free CF20 91015AW (30s - 20min). Optional 2 min start delay. bearings and include thermal overload CF20T 91016AW protection • It shall be possible to remotely select *IPX4 rated speeds using Xpelair switch Ref. 90108AW • Dimensions shall be W x H x D 222 x 252 x 118mm excluding spigot • The unit shall be designed for flush or • The unit shall be BEAB approved and rated surface mounting in walls, ceilings or through at IPX5. The fan shall conform to Building glass (using the GMK kit) supplied Regulations for use in toilets, bathrooms and complete with fixing clamps for flush utility rooms. The fan shall incorporate an mounting automatic air operated backdraught shutter

Xpelair Premier LoVolt LVDX200 & LVCF20

The unit is to be supplied from the Xpelair • A rectangular cut out section shall be • The unit shall be BEAB approved and Premier range by Applied Energy Products Ltd, provided to connect to Xpelair Profile 29 rated at IPX5. The fan shall Morley Way, Peterborough PE2 9JJ flatduct using Xpelair kit Ref. 90547AA conform to Building Regulations for use in toilets, bathrooms and utility rooms Tel. +44 (0)1733 456789 • LVCF20 models shall be supplied with an outside grille • The unit shall be suitable for zone 1 and zone 2 requirements as defined by IEE • LVDX200 shall be operated by a proprietary Model Ref Wiring Regulations 16th Edition BS remote switch or sensor LVDX200 91453AW 7674:2001 • LVDX200T shall have an adjustable overrun LVDX200T 91040AW • The housing and stylish air inlet shall be timer (30sec-20mins) with 2 min start delay LVCF20 91041AW moulded in high gloss white ABS • LVCF20 shall have automatic operation LVCF20T 91042AW • The front cover shall be held in position through integral humidity sensor, manual by the retaining clips to facilitate removal boost speed via pullcord and trickle • The unit shall be 12V Safety Extra Low and adjustment Voltage with a separate SELV transformer ventilation • The motor shall be maintenance free, • LVCF20T shall have automatic operation • The unit shall be designed for surface or totally enclosed, fitted with sealed self through integral humidity sensor, manual flush mounting using the fixing clamps aligning bearings and thermal overload boost speed via pullcord and trickle provided, in walls, ceilings or mounting protection through glass using the GMK kit ventilation. Adjustable overrun timer (30sec-20min). 2 min start delay • Dimensions shall be W x H x D • The fan shall incorporate an air operated 222 x 252 x 118mm excluding spigot backdraught shutter.

Xpelair Premier LVCF20T DC

The unit is to be supplied from the Premier • The unit shall be suitable for use as an • The unit shall be rated at IPX5 UltraDC range by Applied Energy Products Ltd. intermittent fan in bathrooms and WCs or as Morley Way, Peterborough PE2 9JJ Tel. a decentralised continuous extract unit for • The fan shall be designed for flush or surface kitchens, utility rooms, bathrooms and WCs mounting on walls or ceiling and shall be +44 (0) 1733 456789 in accordance with the requirements of fitted with an automatic air operated Building Regulations Part L1 backdraught shutter Model Ref • The unit shall be fitted with an UltraDC low • The housing and air inlet fascia shall be Premier LVCF20T DC 92288AW energy external rotor motor with maintenance moulded in high gloss ABS free greased for life bearings • The front cover shall be held in position by • The unit shall be suitable for use in the splash two retaining clips to facilitate removal zone of a bath or shower identified as Zone 1 in the IEE regulations 16th edition. A separate Dimensions: SELV transformer shall be supplied with the W x L x H unit which shall be installed outside of Splash 222 x 252 x 118 excluding spigot zones 1 and 2

160 Xpelair Premier CF20/40T CV

The unit is to be supplied from the Premier intermittent ventilation with manual override in • An external grille shall be supplied with UltraCV range by Applied Energy Products Ltd. Kitchens and Bathrooms and continuous the fan decentralised ventilation in Kitchens, Utility Morley Way, Peterborough PE2 9JJ Tel. • The unit shall be rated at IPX5 making it rooms, Bathrooms and Sanitary +44 (0) 1733 456789 suitable for use in the splash zone 1 of a bath accommodation or shower • Performance shall be set by the installer by • The fan housing shall be moulded in high Model Ref way of installer accessible dip switches gloss ABS with the air inlet discreetly CF20/40T UltraCV 92293AW • For internal rooms, the Timer when selected concealed behind a baffle to the front cover shall be factory set at 15 minutes in • The front cover assembly shall be held in accordance with Part F1 but shall be installer position by clips to facilitate ease of removal • The unit shall feature UltraEC technology adjustable up to 20 minutes (minimum period for fan adjustment reducing energy use and providing longer shall be 20 seconds) motor life • A balanced impeller shall be integral with the • There shall be a 'Quick visit' timer feature motor assembly • The motor shall be of external rotor preventing nuisance tripping if the room is construction with sealed, maintenance free occupied for less than 2 minutes • The fan shall be rated at 220-240 50/60Hz bearings and include safety thermal overload protection • The fan shall have a constant volume feature Overall dimensions W x H x D which maintains the chosen performance 252 x 300 x 156mm excluding spigot • A choice of installation performances shall be irrespective system pressure up to 100Pa available to meet the installed performance requirements of Building Regulations Part F1- • The unit shall be designed for flush or surface intermittent ventilation in Kitchens, Utility mounting in walls or ceilings using the rooms, Bathrooms and Sanitary accessories provided accommodation; Humidity controlled

Xpelair Profile 29

The components are to be supplied from the Model Ref • Profile 29 system components shall be used Xpelair Profile 29 range by Applied Energy Elbow bend/plenum 91112AA in conjunction with Premier DX200 and CF20 models Products Ltd. Morley Way, Peterborough PE2 Long airbrick adaptor 91102AA 9JJ Tel. +44 (0)1733 456789 • The system shall use a XFD kit to connect to Universal support clip 91114AA the fan with further components appropriate Duct connector 91107AA for the application Airbricks horizontal Model Ref • The outer dimensions shall be w234 x h29mm terracotta 91103AA 2 Premier flat ducting adaptor 90547AA and have a cross sectional area of 5630mm white 91126AA Straight duct 2m 91106AA • Xpelair Profile 29 shall be manufactured in brown 91127AA self extinguishing flame retardant PVC Horizontal 45 bend 91109AA Cotswold stone 91128AA conforming to DIN 4102 B1 and UL94 V2 Horizontal 90 bend 91108AA Soldier course* 91246AA Vertical 45 bend 91111AA 100mm telescopic wall tube 91247AA Vertical 90 bend 91110AA *terracotta Round to rectangular adaptor 91113AA n o i Xpelair DX100 t a c

The unit is to be supplied from the Xpelair DX100 • The unit shall be designed for wall, • In addition it shall conform to Building i f

range by Applied Energy Products Ltd, ceiling, shaft (or window mounting in Regulations for use in toilets and bathrooms i

Morley Way, Peterborough PE2 9JJ glass up to 6mm thick) using the kit c • Dimensions shall be W x H x D

provided. An air operated backdraught e Tel. +44 (0)1733 456789 165 x 155 x 43mm excluding spigot

shutter shall be included p

• PC - Pullcord S • The fan housing shall be moulded in high

Model Ref l gloss white ABS and be of modern • T - Timer (2 - 20mins)

DX100 90839AW design with finger guarding for additional a

• H - Humidistat control (50 - 90%RH) c safety protection DX100PC 90840AW i

• HP - Humidistat/Timer control p DX100T 90841AW • The motor shall be lubricated for life with DX100H 90842AW built in safety thermal overload protection • PIR - Passive infrared control y T DX100HP 90843AW • The unit shall be rated at IPX5 r DX100PIR* 90844AW i a

*IPX4 rated l e p X www.xpelair.co.uk 161 Xpelair Typical Specification

Xpelair LoVolt LV100

The unit is to be supplied from the Xpelair • The unit shall be 12V Safety Extra Low • The unit shall be rated at IPX5. LoVolt 100mm range by Applied Energy Voltage design and supplied complete In addition it shall conform to Building Products Ltd, Morley Way, Peterborough PE2 with a remote SELV transformer Regulations for use in toilets and bathrooms 9JJ Tel. +44 (0)1733 456789 • The unit shall be designed for wall, • Dimensions shall be W x H x D ceiling, shaft (or window mounting in 165 x 155 x 42mm excluding spigot glass up to 6mm thick) using the kit • PC - Pullcord Model Ref provided. An air operated backdraught LV100 90845AW shutter shall be included • T - Timer (2 - 20mins)

LV100PC 90846AW • The fan housing shall be moulded in • H - Humidistat control (50 - 90%RH) LV100T 90847AW high gloss white ABS and be of modern design with finger guarding for additional • HP - Humidistat/Timer control LV100H 90848AW safety protection • PIR - Passive infrared control LV100HP 90849AW • The motor shall be lubricated for life with LV100PIR 90867AW built in safety thermal overload protection

Xpelair Slimline 100

The unit is to be supplied from the Xpelair • The unit shall be designed for wall, ceiling, • In addition it shall conform to Building SL100 & SL150 range by Applied Energy shaft (or window mounting in glass up to Regulations for use in toilets and bathrooms Products Ltd, Morley Way, Peterborough PE2 6mm thick) using the kit provided • P models shall include integral pullcord 9JJ Tel. +44 (0)1733 456789 • Shall be designed so that the front grille • T models shall include integral timer control thickness is no more than 10mm (3 - 15mins) Model Ref • The fan housing shall be moulded in • HT models shall include integral humidity high gloss white ABS and be of modern SL100 91225AW control (45 - 99%RH) and timer control design with finger guarding for additional SL100P 91226AW safety protection • HP models shall include a variable speed SL100T 91227AW humidistat with integral pullcord giving full • The motor shall be lubricated for life with SL100HT 91228AW speed override built in safety thermal overload protection • Dimensions shall be W x H x D • The unit shall be rated at IPX4 and a 140 x 140 x 125mm (including 15mm flange) double insulated appliance

Xpelair CentrX

The unit is to be supplied from the Xpelair • The unit shall be of panel design with a • The motor shall be fitted with sealed self CentrX range by Applied Energy Products Ltd, centrifugal high pressure performance aligning maintenance free bearings and Morley Way, Peterborough PE2 9JJ characteristic. The spigot outlet shall be include thermal overload protection suitable for connection to 100mm Tel. +44 (0)1733 456789 flexible or rigid wall tubes or ducting • P models shall include integral pullcord

• Models shall be available with built in • T models shall include integral timer control Model Ref time overrun and built in humidistat (3 - 15mins) auto control CT100 91236AW • HT models shall include integral humidity CT100T 91237AW • The unit shall be rated at IPX4. The fan control (45 - 99%RH) and timer control shall conform to Building Regulations for use CT100HT 91238AW • Dimensions shall be: W x H x D in toilets, bathrooms and utility rooms CT100+ 91239AW CT100 190 x 190 x 130mm CT100+P 91240AW • The housing shall be moulded in high CT100+ 208 x 208 x 139mm including gloss white ABS. The front cover shall be 17mm spigot CT100+HT 91241AW removable to facilitate removal and adjustment

162 Xpelair XIL Inline Shower Fan Systems

The unit is to be supplied from the Xpelair XIL The system shall comprise: • The motor shall be lubricated for life with built range by Applied Energy Products Ltd, in safety thermal overload protection • Inline axial fan Morley Way, Peterborough PE2 9JJ • The fan shall comply with Building • 3m of 100mm dia. flexible duct Tel. +44 (0)1733 456789 Regulations for use in bathrooms and shower • Four fixing clips rooms when typically installed Model Ref • Inline backdraught shutter XIL System • Internal ceiling grille in white XIL100 90329AW XIL125 91242AW • Outside soffit/wall grille in brown XIL150 91244AW • T models shall include overrun timer function adjustable between 2 - 20mins (100 range) XIL T System with integral overrun timer and 3 - 15mins (125/150 ranges) XIL100T 90330AW • The fan housing and grilles shall be moulded XIL125T 91243AW in ABS. The internal and external grilles should have finger guard protection. The fan and air XIL150T 91245AW operated backdraught shutter shall be installed in the space above the ceiling at the XXS100 fan only 90331AW highest point in the system XXS100T fan only 90332AW

Xpelair BriteX LoVolt & BriteX Turbo

The unit is to be supplied from the Xpelair • The system shall be suitable for installation in • The System shall be guaranteed for 3 years BriteX range by Applied Energy Products Ltd. Zone 1 as defined by the IEE regulations (BriteX LoVolt) or 2 years (BriteX Turbo) 16th Edition Morley Way, Peterborough PE2 9JJ • Supply voltage 220-240V 50Hz Tel. +44 (0)1733 456789 • The lamp shall be 12V 50W Safety Extra Low • T models shall include integral timer function Voltage sealed dichroic lamp with SELV adjustable between:- transformer. The fan shall be sited above the Britex Lovolt 1-20 min Model Ref ceiling at the highest point in the duct run. The Britex Turbo 3-15 min BX100C 92278AW fan shall be manufactured in ABS and have a maintenance free motor with safety thermal BX100W 92276AW overload protection. The fan shall be IPX4 BX100CT 92279AW when installed as per the instructions and BX100WT 92277AW double insulated Class II. The kit shall contain ducting, duct ties and a grille suitable for soffit BX100+C 91249AW or gable end fitting BX100+W 91248AW BX100+CT 91251AW BX100+WT 91250AW n

Xpelair XIM o i t The unit is to be supplied from the Xpelair XIM • The unit shall be suitable for ducted • All models shall be 2 speed (except XIM100 a range by Applied Energy Products Ltd. applications where high humidity is present and XIM100T) c i

Morley Way, Peterborough PE2 9JJ. • The unit shall be of polymer construction with • An optional change over switch shall be f i Tel. +44 (0)1733 456789 spigots for attachment to the ductwork available, COS Ref. 90108AW c

• The impeller shall be of mixed flow design • The unit shall be a double insulated e

Model Ref with matching guide vanes. A QuickLock appliance p

installation cradle shall be provided for easy S • Overall dimensions W x H x D XIM100* 91252AW installation l XIM100T* 91253AW 100mm 189 x 177 x 238mm a • The motor shall be maintenance free, with

125mm 200 x 217 x 263mm c XIM100+ 91254AW greased for life bearings and safety 150mm 192 x 244 x 293mm i XIM125 91255AW thermal overload protection 200mm 230 x 279 x 354mm p XIM150 91256AW • T models shall include integral timer function y XIM150T 91257AW adjustable between 3 - 15mins T r

XIM200 91258AW • The units shall be IPX4 rated and conform to i

*IPX2 rated Building Regulations for toilets, shower a rooms and bathrooms l e p X www.xpelair.co.uk 163 Xpelair Typical Specification

Xpelair Slimline 150

The unit is to be supplied from the Xpelair • Shall be designed so that the front grille • P models shall include integral pullcord SL100 & SL150 range by Applied Energy thickness is no more than 10mm • T models shall include integral timer control Products Ltd, Morley Way, Peterborough PE2 • The fan housing shall be moulded in (45sec - 15mins) 9JJ Tel. +44 (0)1733 456789 high gloss white ABS and be of modern • HT models shall include integral humidity design with finger guarding for additional control (45 - 99%RH) and timer control safety protection Model Ref • HP models shall include a variable speed • The motor shall be lubricated for life with SL150 91229AW humidistat with integral pullcord giving full built in safety thermal overload protection SL150P 91230AW speed override • The unit shall be rated at IPX4 and a SL150HT 91231AW • Dimensions shall be W x H x D double insulated appliance SL150HP 91496AW 190 x 190 x 130mm including SG150HP 92349AW • In addition it shall conform to Building (front flange depth 15mm) Regulations for use in toilets and bathrooms • The unit shall be designed for wall, ceiling, shaft (or window mounting in glass up to 6mm thick) using the kit provided

Xpelair GX6, GXC6 & GXC9

The unit is to be supplied from the Xpelair • The extract fan shall be suitable for window, • Operation of the shutter shall be by a silent GX/GXC range by Applied Energy Products Ltd. wall, or panel mounting. An optional WK tube electrothermal actuator on GX6 variants and Morley Way, Peterborough PE2 9JJ shall be used for wall installation GXC6T; pullcord on GXC6 and GXC9 Tel. +44 (0)1733 456789 • The motor shall be high efficiency, totally • The unit shall be BEAB approved enclosed, with sealed for life bearings and • T models shall include integral timer function safety thermal overload protection Model Ref adjustable between 2-20mins • The motor /impeller assembly shall be • GX6HT shall include integral humidity GXC6 90850AW housed in a rigid ABS moulded duct to function (50-90%RH) and timer GXC6T 90861AW ensure even, optimum impeller tip clearance • GX6HT2 shall include integral humidity and GX6 90800AW • The inner grille shall be moulded in timer function with 2 speeds GX6T 90812AW white ABS with a high gloss finish and GX6HT 90814AW incorporate a finger guard and removable • GXC6SC shall be speed adjustable shutter cassette for ease of maintenance GX6HT2 90863AW • Overall dimensions for • The impeller shall be pre-balanced and GXC6SC 91142AW removable for cleaning by means of a shaft W x H x D GXC9 89995AW screw fixing GXC6 & GX6 210 x 226 x 112mm GXC9 294 x 312 x 117mm • A trickle vent option shall be incorporated into the mechanism to provide 4000mm2 passive ventilation when the fan is Off

Xpelair GX6 EC2, GXC6 EC2

The unit is to be supplied from the Xpelair • The motor shall be an UltraEC type external • The inner grille shall be moulded in whit ABS GX/GXC EC2 range by Applied Energy rotor motor with sealed for life bearings and with a high gloss finish and incorporate a Products Ltd. Morley Way, Peterborough PE2 safety thermal overload protection. finger guard and removable shutter cassette Class II appliance for ease of maintenance 9JJ Tel. +44 (0) 1733 456789 • The products shall be capable to be set at • The impeller shall be pre balanced and one of two extract performances which will removable for cleaning by means of a shaft Model Ref satisfy Building Regulations Part F1 for screw fixing intermittant kitchen and Utility room use. GX6 EC2 92294AW • Operation of the shutter shall be by a silent The rated wattage shall not exceed electrothermal actuator on GX6 EC2 and GXC6 EC2 92295AW 0.036w/l/s for GX6 EC2 and 0.027w/l/s for pullcord on the GXC6 EC2 GXC6 EC2 • The 150mm extract fan shall be suitable for window, wall or panel mounting • The product shall be suitable for ambient temperatures up to 50C Overall dimensions for: • Hole size in glass shall be 184mm. An optional WK tube shall be used for wall • The motor / impeller shall be housed in a rigid GX6/GXC6 EC2 installation ABS moulded duct to ensure even optimum WxHxD impeller clearance 210 x 226 x 112 mm

164 Xpelair Premier DX400 & CF40

The unit is to be supplied from the Xpelair • DX400 fans shall have a two speed • The motor shall be of external rotor Premier range by Applied Energy Products Ltd, running facility and CF40 fans a room construction, IP44 rated with sealed size selector in the control system to maintenance free bearings and include Morley Way, Peterborough PE2 9JJ provide three preset speed settings for inbuilt safety thermal overload protection Tel. +44 (0)1733 456789 optimum room performance • A dynamically balanced balanced impeller • A further option of trickle ventilation shall shall be integral with the motor assembly be provided by way of a preset switch on Model Ref the unit (not DX400) • PC models shall be pullcord operated DX400 91083AW • CF versions shall be manually • T models shall include integral timer function DX400T 91084AW adjustable between 50 and 90% RH with adjustable between 30s-20mins DX400PC 91100AW fan running status indicated by lights • RS shall be remote switched use with MOS Ref. 90199AW DX400RS 91085AW • The unit shall be BEAB approved and rated IPX5. in addition the fan shall • TD shall have an integral timer CF40 91086AW conform to Building Regulations for use CF40TD 91087AW in kitchens, utility rooms and bathrooms • RSTD shall have an integral timer and remote delay switch. MOS Ref. 90199AW CF40RSTD 91088AW • The fan housing shall be moulded in high gloss white ABS and be of modern design • Overall dimensions: W x H x D • The unit shall be designed for flush or with the air inlet discreetly concealed 249 x 297 x 147mm excluding 35mm spigot surface mounting in walls and ceilings behind a stylish baffle fixed to the front cover using the fixing clamps provided • The front cover assembly shall be • An external grille shall be supplied with held in position by clips to facilitate ease the fan of removal for fan adjustment

Xpelair Kitchen Canopies

The unit is to be supplied from the Xpelair Built in Canopies • All models shall be suitable for extraction to Nouvelle Cuisine range by Applied Energy the outside using 125mm Xflex or Profile 60 Inset 520mm 282mm flat duct systems or can be set for Products Ltd, Morley Way, Peterborough Integrated 600mm recirculation, optional carbon filters to be PE2 9JJ Tel. +44 (0)1733 456789 available Standard 600mm Standard Plus (SS) 600mm • The Wall, Island and Standard Plus models shall be fitted with washable grease filters, Model disposable acrylic filters on other integrated models Wall Chimney Canopies • The kitchen canopy shall be offered in a Curved 900mm range of styles to suit wall, island and • The three speed continuously rated motors integrated applications. Models shall be Flat 900mm 600mm shall be maintenance free available in stainless steel/glass or Box 900mm 700mm white/brown finish to suit kitchen decor • There shall be a choice of performance to and have seperate switchable integrated fan meet the minimum requirements of Building Tonda 900mm 600mm and lighting Regulations Chimney 900mm 600mm • Three year guarantee Island Chimney Canopy Island 900mm 600mm n o i t

Xpelair Profile 60 a c The components are to be supplied from the • Also suitable for Xpelair range of kitchen i Elbow/plenum to 125mm dia 91259AA f

canopies i Xpelair Profile 60 range by Applied Energy Elbow/plenum to 150mm dia 91483AA c Products Ltd. Morley Way, Peterborough PE2 • The system shall use a plenum kit to connect

Duct coupling 89757AA e 9JJ. Tel. +44 (0)1733 456789 to the fan with further components T piece 90091AA p appropriate for the application Support clip 89756AA S

• The outer dimensions shall be 204 x 60mm l Model Ref Wall outlet grille 89751AA

and have a cross sectional area of a Straight duct 1m 89755AA 2

Flexible ducting 0.5m 91484AA 11200mm c Straight duct 1.5m 91188AA Fire break intumescent 91975AA i

• Xpelair Profile 60 shall be manufactured in p Horizontal bend adjustable 89750AA Round to rectangular adaptor 91482AA self extinguishing flame retardant PVC y

Horizontal 90 bend 89754AA conforming to DIN 4102 B.M1 T • Profile 60 system components shall be used

Vertical 90 bend 89753AA in conjunction with Premier DX200 and CF20, r i DX400 and CF40 models set at high speed

Elbow/plenum to 100mm dia 89752AA a l e p X www.xpelair.co.uk 165 Xpelair Typical Specification

Xpelair CX10 & CMF

The unit is to be supplied from the Xpelair CX • The unit shall be designed for flush ceiling • CMF models shall have a cassette style & CMF range by Applied Energy Products mounting in incorporate a finger guard for construction allowing first-fit ductwork to be Ltd. Morley Way, Peterborough PE2 9JJ safety protection fitted prior to the installment of the unit. Tel. +44 (0)1733 456789 • CX model shall be an axial fan unit and • Motors shall be lubricated for life and be CMF models centrifugal maintenance free

Model Ref • The units shall be fully recessed with only the • Safety thermal overload protection shall high gloss ABS moulded grille showing be fitted CX10 90209AB • There shall be spigots for the attachment of • The fascia grilles shall be demountable to CMF171 89955AW optional ductwork facilitate cleaning CMF241 89956AW CMF271 89957AW

Xpelair Xplus Whole House Multipoint Extract Fans

The unit is to be supplied from the Xpelair Xplus • The extract fan unit shall be designed for the • The fan shall have a backward centrifugal range by Applied Energy Products Ltd. Morley continuous extraction of condensation and curved impeller. The motor shall be rated for Way, Peterborough PE2 9JJ odours from the ‘wet’ rooms of a dwelling. It continuous running, have sealed for life may be installed in a loft space or services bearings and be maintenance free. AC and Tel. +44 (0)1733 456789 cupboard. Suitable ductwork such as DC motor variants shall be available Xflex125 of Profile 60 shall be used with • All models shall be speed controllable using RegulAir ventilation terminals Model Ref an optional hard wired switch. Xplus Xplus 275 91260AW • The fan housing shall be manufactured in a 340 DCFRF shall also be available with a polymeric material and be fitted with three 100M (line of sight) wireless transmitter Xplus 340 91261AW 125mm ‘room side’ extract spigots and one control system Xplus 340 DC 91262AW 125mm discharge spigot terminating at a wall • Xplus 340 DC shall be AppendixQ listed and or roof Xplus 340 DCRF 91263AW meet Best Pactice Criteria Controller 91457AW

Xpelair Xplus 250 & 400 DC 8CV

The unit is to be supplied from the Xpelair • To avoid tampering with speed settings in • The unit shall have 3 intake connections of LoSound range by Applied Energy Products use, the unit must be powered Off if switch 125mm diameter and1 extract connection Ltd. Morley Way, Peterborough PE2 9JJ. adjustment needs to be made. Altering the 125mm diameter switch position when the unit is powered will Tel. +44 (0)1733 456789 • Motor shall be Energy saving Longlife not change the speed setting UltraDC external rotor motor with greased for • A Boost function shall be available to life ball bearings Model Ref increase extract rate by one set point i.e. • Systems using these products should design the boost speed of speed 1 is equivalent to Xplus 250DC8CV 92290AW to achieve a duct velocity of less than 3m/s in speed 2 etc. Speed 8 boost is 36m_/h above order to minimise noise. The fan shall not Xplus 400DC8CV 92100AW speed 8 exceed a specific fan power of 0.6 w/l/s • Boost function shall be operated using @ 50pa standard Xpelair controllers i.e. COS switch, • There shall be two models with performances • Xplus 250 DC 8CV shall be Appendix listed XRH, XPIRA, DT20, and AQS controllers ranging from 48m3/h to 255m3/h and 206m3/h and meet Best Practice Criteria to 402m3/h (at 0Pa) • The product shall be rated at 230V, 50/60Hz, 1 phase • Each model shall have 8 selectable set up speeds to suit installation application with • Main body shall be manufactured in impact speeds in accordance with Building resistant polymeric material Regulations Part F1 continuous extract • The unit shall be supplied with 1m of requirements selected via an integral switch 4-core cable accessible from the outside of the product

166 Xpelair Xcell 150 & 200

Wholehouse ventilation unit from the Xpelair • The MVHR unit shall have a slimline • Hygenic coated steel anti-bacterial Xcell range by Applied Energy Products Ltd. insulated steel case with sealed access condensate tray and outlet shall be fitted Morley Way, Peterborough PE2 9JJ panel. The unit shall be suitable for ceiling • Xcell 150 has two 125mm roomside Tel. +44 (0)1733 456789 or loft mounting in confined spaces spigots • The heat recovery cell shall be up to 92% • Xcell 150R has a pair of twin flat duct efficiency depending on volume setting Model Ref spigots for connection to Profile 60 duct • The unit shall be fitted with multispeed Xcell 150 91981AA • Xcell 150V is a vertical version with all double inlet fans for whisper quiet Xcell 150R 91976AA spigots on top performance to be set at a speed based Xcell 150V 92004AA on the volume / duty of the dwelling in • Xcell 200 has two 150mm roomside Xcell 200 91977AA accordance with Building Regulations Part spigots F1. A remotely fitted switch shall be Xcell 200BP 91979AA provided with the unit • Xcell 200R has two pairs of twin flat duct Xcell 200R 91978AA spigots for connection to Profile 60 duct • Supply and exhaust filters shall protect Xcell 200RBP 91980AA the cell (Xcell 200 only) • Xcell 200BP and 200RBP shall have 100% motorised summer bypass

Xpelair Xcell 270 LongLife

The unit is to be supplied from the Xpelair • The MVHR unit shall be designed for • A hinged door shall be provided on the Xcell range by Applied Energy Products Ltd. installation in well insulated dwellings front of the cabinet for access to the stage 1 G4 filters and occasional visual Morley Way, Peterborough PE2 9JJ • The unit shall be wall mounted using a inspection of the cell Tel. +44 (0)1733 456789 wall bracket provided with 150mm duct spigots ready for connection to supply • The unit shall have 3 speed from a choice and return air ducts and ductwork to a of twelve to match the volume of the Model Ref wall or roof termination dwelling continuous ventilation including the choice of a boost speed if required. Xcell 270 91264AW • The cabinet shall be manufactured in steel As a result the heat recovery cell and powder coated in beige Xcell 270BP 91265AW shall be up to 93% efficient • The inner components and scroll shall be • The vent shall be be controlled by 3 made from non hygroscopic high density speed selective switch Ref. 91266AW structural foam mouldings with an integral double condensate tray. Provision shall be made for alternative condensate drain off points

Xpelair Xcell 300 & 400 LongLife

The unit is to be supplied from the Xpelair • The MVHR unit shall be designed for • Access shall be provided to the stage 1

Xcell range by Applied Energy Products Ltd. installation in well insulated dwellings G3 filters. The unit shall have a choice of n

speeds to match the volume of the dwelling o

Morley Way, Peterborough PE2 9JJ • The unit shall be wall mounted using a wall i in order to provide half an air change per Tel. +44 (0)1733 456789 bracket and provided with 150mm duct t hour continuous ventilation including the spigots on the 300 models and 180mm duct a choice of a boost speed if required. As a spigots on the 400 models ready for c result the heat recovery cell shall be up to i Model Ref connection to supply and return air ducts and f

91% efficient - certified by TZWL, depending i ductwork to a wall or roof terminations

Xcell 300 91267AW on chosen speed. The fans shall be c

Xcell 400 91269AW • The cabinet shall be manufactured in electronically balanced to provide equal e

extraction and air supply p Xcell 300BP 91268AW polypropylene to RAL 9002: White Xcell 400BP 91270AW • The inner components and scroll shall be • The motors shall be UltraDC motors S made from non hygroscopic high density with maintenance free greased for life l

structural foam mouldings with an integral ball bearings a

double condensate tray. Provision shall be c • A supply lead shall be provided to i made for alternative condensate drain facilitate wiring p off points y • Overall Dimensions W x H x D • Backward curved impeller T 740 x 600 x 540mm r

Weight :32kg i a l e p X www.xpelair.co.uk 167 Xpelair Typical Specification

Xpelair Xcell 600 Low Profile

The unit is to be supplied from the Xpelair • The MVHR unit shall have a slimline insulated • The condensate tray shall have an anti Xcell range by Applied Energy Products Ltd. steel case and sealed access panel. The unit bacterial coating. The unit shall have 200mm Morley Way, Peterborough PE2 9JJ shall be suitable for ceiling or loft mounting in spigots on the room side and discharge side confined spaces using the integral mounting Tel. +44 (0)1733 456789 • A further model shall be available fitted with a point detail provided motorised summer Bypass feature • The heat recovery unit shall be up to 70% • Dimensions H x W x L Model Ref efficient depending on volume setting and be 250 x 750 x 1100mm (Excluding spigots) Xcell 600 92002AA compatible with systems Xcell 600BP 92003AA • The unit shall be fitted with double inlet fans for quiet operation and be set at a speed calculated on the volume/duty of the dwelling in accordance with Building Regulations Part F1. A remotely fitted single gang switch shall be provided with the unit. Heavy duty supply and exhaust filters shall be included in the unit

Xpelair Profile 150

The components are to be supplied from the Roof Cowl 91277AA • A selection of bends constructed of the Xpelair Profile 150 range by Applied Energy Wall Cowl 91278AA same material shall be available. The duct Products Ltd. Morley Way, Peterborough and bends shall be connected using • Profile 150 ductwork shall be used in 100mm collar connectors with built in PE2 9JJ. Tel. +44 (0)1733 456789 conjunction with Xflex ductwork and Profile internal stops. For duct sections requiring 60 flat duct to provide the distribution subsequent disconnection for service or system for Xcell MVHR units cleaning access, a quick release collar Model Ref shall be available 2.5m straight duct 91272AA • Ducting shall be manufactured in steam resistant, self extinguishing EPE to class • Further interconnecting components shall 90º bend 91273AA B1, DIN 4102 be available from the Profile 60 flat duct 45º bend 91274AA range to complete the system • Density shall be 50kg/m3 and the duct 30º bend 91275AA shall have a thermal coefficient of 0.040 15º bend 91276AA W/m. K measured at 0ºC in accordance Pushfit collar 91279AA with DIN 52613. Temperature range shall be -40 to +100ºC Snap Clamp Collar 91280AA

Xpelair EverDri LongLife

The unit is to be supplied from the Xpelair EverDri • The unit shall continuously monitor the loft air • The fan motor shall be a high efficiency range by Applied Energy Products Ltd. Morley temperature and will automatically adjust the electronically commutated DC motor with Way, Peterborough PE2 9JJ. performance of the fan if the temperature sealed for life maintenance free bearings and Tel. +44 (0)1733 456789 rises above or falls below 19°C. thermal protection. Quiet running of the fan shall be ensured by incorporation of a • The fan shall automatically suspend forward curved centrifugal impeller operating operation if the temperature rises above 25°C Model Ref and re-continue when the temperature falls in a double inlet scroll housing. back down below that point. XEDL 90998AA • The fan shall be supplied complete with a • Four performance selection settings shall be supply cord fitted. • For installation in houses provided on the unit to provide the optimum • The incoming air shall pass through a filter, • The fan unit shall be designed for fully performance settings for differing dwelling these are to be available as a spare part automatic operation and continuous running sizes and severity of condensation. from Xpelair. and supplied complete with anti vibration • The operation status of the unit shall be mountings, interconnecting flexible ducting indicated by means of LED’s on the and purpose designed diffuser outlet with control panel. direction baffles

168 Xpelair LoVolt XHR150

The unit is to be supplied from the Xpelair XHR • The unit shall have two speeds: trickle for outgoing air. The incoming air shall be filtered range by Applied Energy Products Ltd. Morley constant background ventilation and a boost through a foam filter medium speed operated manually by way of a built in Way, Peterborough PE2 9JJ • The ventilator shall be fitted with a long life pullcord on the PC model and by way of an Tel. +44 (0)1733 456789 aluminium heat recovery cell having an automatic humidity sensor control on the efficiency of up to 80% HP model • BBA Agreement Board Certification Model Ref • The unit shall be of cylindrical construction XHR150PC 90821AA with integral outside intake / extract points • Overall dimensions: W x H x L XHR150HP 90820AA • The internal grille shall be moulded in 200 x 180 x 532mm white ABS with a high gloss finish and • The single room heat recovery ventilator shall incorporate a safety finger guard. To avoid be a Safety Extra Low Voltage LoVolt product cross contamination, the incoming air shall and supplied complete with exterior weather be delivered to the room at the side of the resistant bezel and a remote SELV transformer grille ensuring a 90º separation from the

Xpelair AutoFlow

The unit is to be supplied from the Xpelair • The ventilator shall be installed using a • The vent disc shall be capable of being AutoFlow range by Applied Energy Products core cutting drill adjusted manually by rotating the disc from automatic mode to increase or decrease the Ltd. Morley Way, Peterborough PE2 9JJ • The Passive ventilator shall be self regulating opening size. The temperature range shall be Tel. +44 (0)1733 456789 using a temperature sensitive piston to from -5ºC to +10ºC adjust the airflow in relation to the outside air temperature. The piston shall be maintenance • The disc, wall tube and external grille shall be Model Ref free. In automatic mode the airflow shall manufactured in ABS. The inside disc, bezel AutoFlow80 91295AW decrease with declining outdoor temperature and the external weather grille shall be white and increase with rising outdoor temperature. in colour AutoFlow100 91296AW The vent disc shall be insulated and tight AutoFlow160 91297AW fitting to the bezel when closed

Xpelair GX6, GX9 & GX12

The unit is to be supplied from the Xpelair GX • All models shall have totally enclosed AC • An outer grille shall be provided, this to be range by Applied Energy Products Ltd. Morley motors with sealed for life bearings with moulded in Shadow Grey ABS with high Way, Peterborough PE2 9JJ external rotor motors on GX9 / GX12 and gloss finish and incorporate weather safety thermal overload protection resistant vanes Tel. +44 (0)1733 456789 • The high efficiency moulded axial bladed • On GX9 and GX12 models customer impeller shall be pre-balanced and electrical connection shall be via an internal n

Model Ref designed for optimum performance and tamper-proof plug and socket o i

ease of removal for cleaning t GX6 90800AW • On GX9 and GX12 models a concealed a GX9 89994AW • Motor/impeller assembly shall be in a rigid switch on the unit shall predetermine the c GX12 90012AW ABS housing with high gloss white finish mode of operation: intake only, or extract i f

and incorporate a finger guard only or optional controller operation for i • The fan shall be suitable for window speed control and reversibility c • A passive trickle vent option shall be mounting (or wall mounting using optional incorporated into the inner grille shutter • The unit shall be BEAB approved e wall kit) cassette to provide low level ventilation Overall dimensions: W x H x D p

• Performance shall have been proven by when the unit is not in use GX6 210 x 226 x 112mm S

type testing in accordance with BS 848 Part GX9 294 x 312 x 117mm l • The shutter shall be operated by a silent

1 and FID performance determined to be: GX12 380 x 408 x 161mm a electrothermal actuator c 3 (m /h) extract intake External depth shall be 32mm/32mm i • It shall be possible to remove the inner grille

GX6 266 and 34mm respectively p and shutter cassette separately for cleaning GX9 728 456 y

GX12 1614 1002 T r i a l e p X www.xpelair.co.uk 169 Xpelair Typical Specification

Xpelair PX6, PX9 & PX12

The unit is to be supplied from the Xpelair PX • All models shall have totally enclosed AC • Customer electrical connection shall be via range by Applied Energy Products Ltd. motors with sealed for life bearings, with an internal tamper- proof plug and socket Morley Way, Peterborough PE2 9JJ external rotor motors on PX9 / PX12, and on PX9 and PX12 models safety thermal overload protection Tel. +44 (0)1733 456789 • A concealed switch on the unit shall • The high efficiency moulded axial bladed predetermine the mode of operation: intake impeller shall be pre-balanced and only, or extract only or optional controller Model Ref designed for optimum performance and operation for speed control and reversibility PX9 and PX12 only) PX6 91300AW ease of removal for cleaning (

PX9 91299AW • Motor/impeller assembly shall be in a rigid • The unit shall be BEAB approved PX12 91298AW ABS housing with high gloss white finish • Overall internal projection shall be: and incorporate a finger guard • The fan shall be suitable for ceiling or panel PX6 11mm mounting. Performance shall have been • A passive trickle vent option shall be PX9 / PX12 18mm proven by type testing in accordance with incorporated into the inner grille shutter BS 848 Part 1 and FID performance cassette to provide low level ventilation determined to be: when the unit is not in use

(m3/h) extract intake • The shutter shall be operated by a silent electrothermal actuator PX6 246 PX9 790 458 • It shall be possible to remove the inner grille PX12 1712 1070 and shutter cassette separately for cleaning on PX9 and PX12 models

Xpelair RX6, RX9 & RX12

The unit is to be supplied from the Xpelair RX • The fan shall be suitable for roof mounting • A passive trickle vent option shall be range by Applied Energy Products Ltd. through clear and obscure glazing, incorporated into the inner grille shutter Morley Way, Peterborough PE2 9JJ polycarbonate sheeting, roof mounting cassette to provide low level ventilation plates and materials up to 25mm when the unit is not in use Tel. +44 (0)1733 456789 • On non smooth glass surfaces a suitable • The shutter shall be operated by a silent sealant shall be applied to the outer gasket electrothermal actuator Model Ref • Performance shall have been proven by • It shall be possible to remove the inner grille RX6 90818AW type testing in accordance with BS 848 Part and shutter cassette separately for cleaning RX9 90424AW 1 and FID performance determined to be: • An outer roof cowl with internal deflector RX12 90425AW (m3/h) extract intake shall be provided, this to be moulded in RX6(T) 206 ABS with high gloss UV stabilised finish on RX9 511 438 RX9 and RX12 models RX12 1100 915 • Customer electrical connection shall be via • All models shall have totally enclosed AC an internal tamper-proof plug and socket on motors with sealed for life bearings, with RX9 and RX12 models external rotor motors on RX9 / RX12, and • A concealed switch on the unit shall safety thermal overload protection predetermine the mode of operation: • The high efficiency moulded axial bladed intake only, or extract only or optional impeller shall be pre-balanced for optimum controller operation performance and ease of removal for • The unit shall be BEAB approved cleaning • Overall internal projection shall be: • Motor/impeller assembly shall be in a rigid ABS housing with high gloss finish and RX6 112mm incorporate a finger guard RX9 117mm RX12 161mm

170 Xpelair WX6, WX9 & WX12

The unit is to be supplied from the Xpelair WX • The fan shall be suitable for wall mounting • The shutter shall be operated by a silent range by Applied Energy Products Ltd. electrothermal actuator • Installation shall be mortar free and the Morley Way, Peterborough PE2 9JJ product shall be supplied complete with • It shall be possible to remove the inner grille Tel. +44 (0)1733 456789 wall liner and shutter cassette separately for cleaning

• Performance shall have been proven by • An outer grille shall be provided, this to Model Ref type testing in accordance with BS 848 Part be moulded in Shadow Grey ABS with 1 and FID performance determined to be: high gloss finish and incorporate WX6 90822AW weatherproof vanes 3 WX6T 90823AW (m /h) extract intake WX6(T) 246 • On WX9 and WX12 models customer WX9 89996AW WX9 783 477 electrical connection shall be via an internal WX12 90011AW WX12 1715 969 tamper-proof plug and socket

• All models shall have totally enclosed AC • On WX9 and WX12 models a concealed motors with sealed for life bearings, with switch on the unit shall predetermine the external rotor motors on WX9 / WX12, and mode of operation: intake only, or extract safety thermal overload protection only or optional controller operation for speed control and reversibility • The high efficiency moulded axial bladed impeller shall be pre-balanced and • The unit shall be BEAB approved designed for optimum performance and • Overall internal projection shall be: ease of removal for cleaning WX6 11mm • Motor/impeller assembly shall be in a rigid WX9 / WX12 18mm ABS housing with high gloss white finish and incorporate a finger guard

• A passive trickle vent option shall be incorporated into the inner grille shutter cassette to provide low level ventilation when the unit is not in use

Xpelair WXXL

The unit is to be supplied from the Xpelair • WXXL models shall have G.S.M.telescopic • On intake models the shutter shall be WXXL range by Applied Energy Products Ltd. wall liner suitable for installation in solid and electro-mechanically opened and be fitted cavity walls from 275mm to 375mm with a washable prefilter Morley Way, Peterborough PE2 9JJ Tel. +44 (0)1733 456789 • The external rotor motor rated at IP44 shall • The fan shall have a built in three speed be fitted with sealed for life maintenance control. A separate slimline three position free bearings and off selection switch shall be provided for remote wall mounting Model Ref • On the inner wall face the fan shall be fitted Extract models with a white epoxy coated aluminium WXXL350 91301AA internal wall grille with removable core for easy cleaning. The fan assembly shall be

WXXL400 91302AA separately guarded for additional safety n o

WXXL450 91303AA • The shutter shall be manufactured from i aluminium housed behind a anodised t Intake models aluminium external weather louvre a c

WXXLS350 91383AA i f

WXXLS400 91384AA i

WXXLS450 91385AA c e p S l a c i p y T r i a l e p X www.xpelair.co.uk 171 Xpelair Typical Specification

Xpelair ChefX

The unit is to be supplied from the Xpelair • Professional quality extract canopy of robust • The motor shall be speed controllable using ChefX range by Applied Energy Products Ltd. construction designed for spot ventilation in optional electronic controller or a five step food preparation and wash up areas. voltage transformer. The tempo model shall Morley Way, Peterborough PE2 9JJ Designed for exhaust operation to the be fitted with a built in speed controller and Tel. +44 (0)1733 456789 outside using rigid ductwork supplied integral lighting by others • Dimensions Model Ref • The canopy housing shall be manufactured in stainless steel with G.S.M internal support H x W x L ChefX Tempo 91309AA Tempo 180 x 600 x 540 ChefX Presto 91310AA • Washable grease filters shall be provided Presto 2350 x 1000 x 460 Mezzo 400 x 1000 x 1000 ChefX Mezzo 91311AA • The hood shall have an integral fan assembly with continuously rated motor and • Performance @ 100pa duct resistance sealed for life beatings. The motor shall be Controls for Presto/Mezzo 3 IPX4 rated and be suitable for temperatures Tempo 400m /h 3 Transformer 91369AA up to 65oC Presto 2200m /h Mezzo 2800m3/h

Xpelair Digitemp

The unit is to be supplied from the Xpelair • The three speed unit shall be designed for • The unit shall be fitted with a pollen filter Digitemp range by Applied Energy Products surface mounting on walls at high or low level without the need for an external • The unit shall be sound insulated and have Ltd. Morley Way, Peterborough PE2 9JJ condenser a super quiet night time function Tel. +44 (0)1733 456789 • Two airside wall tubes shall be provided for • The unit shall have a self-diagnostic system, fitting through 155mm sloping core drilled which displays the condition of the unit using a series of LEDs Model Ref holes through the external wall to the outside Cooling • The maximum length of the tubes shall • Performance shall be as follows: WA210N 91173AA be 1000mm model cooling heating WA245N 91174AA • Two folding external grilles shall be supplied kW kW for fitting through the wall tubes from within WA210N 2.1 Heating & cooling the room WA245N 2.45 WHP210N 2.1 1.9 WHP210N 91175AA • All “cooling only” (WA210N & WA245N) units shall not require a condensate drain WHP245N 2.45 2.03 WHP245N 91154AA • Control shall be from a full function hand • Overall dimensions: held infrared controller with a range of 8m WxHxD 870 x 400 x 280mm Min. diameter of holes: 155mm • The unit refrigerant shall be factory sealed with no opening of the system or hose connections on site

• Refrigerant R410a shall be used having an Ozone Depletion Power Rating of ‘0’

Xpelair WH30, WH60 & WHP30

The unit is to be supplied from the Xpelair WH • The shall be suitable for wall • The terminal block shall be easily accessible range by Applied Energy Products Ltd. Morley mounting and in the case of the 6kW for wiring in position version also suitable for suspension Way, Peterborough PE2 9JJ from above • A control unit shall be available for the 3kW Tel. +44 (0)1733 456789 versions to enable the fan to be run during • The unit shall be capable of being adjusted warmer months or fan heater mode with both in the vertical and horizontal planes thermostatic control for heating and then fixed in position Model Ref • The 3kW versions shall be suitable for WH30 98392AC • The industrial models shall have a robust connection to a single phase supply. The WH60 00147AC steel casing with die cast aluminium guards. 6kW model shall be suitable for connection to either a singe phase or three phase supply WHP30 89999AW • Commercial model shall have a flame retardant polycarbonate/glass filled nylon • Overall dimensions including mounting case finished in white and grey bracket with the unit mounted vertically:

• The heating elements shall be of spiral wound nichrome wire design W x H x D WH30 254 x 368 x 270mm • The fan shall have a totally enclosed, WH60 276 x 429 x 327mm continuously rated, maintenance free motor WHP30 267 x 370 x 370mm with greased for life bearings

172 Xpelair DCH3000A

The unit is to be supplied from the Xpelair DCH • The fan assisted heater shall be suitable for automatic operation and lamp shall indicate range by Applied Energy Products Ltd. Morley wall mounting by way of two mounting the unit is operating points to the rear of the cabinet Way, Peterborough PE2 9JJ. • The unit shall be BEAB approved Tel. +44 (0)1733 456789 • The heater shall not require any feet and • Overall dimensions W x H x D shall be mounted clear of the floor surface 505 x 265 x 110mm Model Ref. • The tangential fan shall be balanced. The motor shall be maintenance free with sealed DCH3000A 90792AW for life bearings and safety thermal overload protection. In addition there shall be a safety cut out with disconnection from the mains to reset

• The heating element shall be a spiral wound design. There shall be three switches providing On/Off, and 1kW, 2kW or 3kW output. A further rotary knob will permit the setting of the for

Xpelair PlinthHeat

The unit is to be supplied from the Xpelair • The fan assisted heater shall be suitable for • A separate kit shall be available for the PlinthHeat range by Applied Energy Products installation in the standard plinths of a remote operated versions consisting of a Ltd. Morley Way, Peterborough PE2 9JJ. kitchen cabinet of 120mm or more thermostat and means of isolation. For safety the heater shall have an automatic Tel. +44 (0)1733 456789 • There shall be an air inlet on either side of thermal cutout the fascia plate and three horizontal outlet grille sections in the centre • The fan shall be of axial design with a Model Ref maintenance free motor having sealed for • The fascia shall be available in two powder life bearings and safety thermal overload With integral control switches: coated finishes and additionally available protection PlinthHeat W 91465AW in brushed stainless steel to match the PlinthHeat B 91466AB kitchen decor • Overall dimensions: W x H x D 470 x 120 x 240mm PlinthHeat S 91312AW • The fascia shall have six fixing holes for With remote controls*: secure attachment to the plinth • Hole dimensions shall be 95 x 440mm PlinthHeat WR 91467AW • The heating element shall be a spiral * Requires remote thermostatic control kit wound design consisting of wall mounted single stage PlinthHeat BR 91468AB variable thermostat, fused double pole • There shall be two switches on the integral PlinthHeat SR 91313AW switch, two gang box and cable wall clamp. control model providing On/Off, and 1kW *remote controller 87100 Ref. 87100 or 2kW output. A lamp shall indicate the output chosen n o i t

Xpelair ScreenHeat a c i

The unit is to be supplied from the Xpelair • The hot air curtain shall be suitable for wall • The fan shall be tangential and balanced to f ScreenHeat range by Applied Energy Products or ceiling mounting using the brackets provide quiet vibration free operation i c Ltd. Morley Way, Peterborough PE2 9JJ. provided. The units shall be in standard

• The element shall be of open coil e 600mm modular widths for side by side Tel. +44 (0)1733 456789 construction and supported by ceramic mounting over larger width doorways p insulators S • The brackets shall have key hole slots for • The casing shall be manufactured in zinc l Model Ref easy installation

coated steel, externally powder coated in a a 1.5 - 3kW 91469AW • Motor shall be shaded pole, maintenance white finish c 2.25 - 4.5kW 91470AW free, with sealed for life bearings and safety i

• Overall dimensions: W x H x D p thermal overload protection

610 x 185 x 105mm y T r i a l e p X www.xpelair.co.uk 173 Xpelair Typical Specification

Xpelair Whispair

The unit is to be supplied from the Xpelair • Air delivery shall be: Xpelair Group Whispair Reversing Whispair range by Applied Energy Products Controller WAC6R 3 Ltd. Morley Way, Peterborough PE2 9JJ. Blade dia. m /h Ref. 21878AW Tel. +44 (0)1733 456789 900mm 8761 • For the simultaneous speed control of 1 to 1200mm 10890 6 Whispair units. Two slide switches 1400mm 12474 provides On/Off operation and infinitely 1500mm 13959 Model Ref variable speed settings. Complete with • The motor shall be a continuously rated, ‘fan running’ indicator light and choice of NWAN36 900mm 90409AW capacitor start and run, external rotor motor winter/summer upwards or downwards airflow NWAN48 1200mm 90410AW design. It shall be maintenance free and incorporate two sets of caged ball bearings Xpelair Whispair Auto Temperature NWAN56 1400mm 90411AW for long life. The motor shall be suitable for Controller AWC hot and humid conditions up to 40ºC NWAN60 1500mm 90412AW Ref. 21857AW • Colour: White • De-stratification controller supplied with two thermo sensors at high / low level • The unit shall be suitable for suspension • Supply Voltage: 220-240V 50/60Hz monitoring between preset minimum and from a ceiling using the ceiling anchor and maximum values. For the simultaneous suspension rod with integral anti-vibration Xpelair Single Whispair Controller WAC1 speed control of 1 to 10 Whispair units. bobbin provided Ref. 21852AW Three slide switches provides On/Off • Two slide switches provides On/Off operation and upwards or downwards • Two lengths of rods shall be provided operation and 5 speed settings. Complete rotation, manual override namely 375mm and 750mm with transformer controller for quiet operation and ‘fan running’ indicator light • Complete with fan running light • The fan blades shall be powder coated steel and suitable for high humidity Xpelair Group Whispair Controller WAC6 • w210 x h86 x d45mm environments Ref. 21853AW • For the simultaneous speed control of 1 to 6 Whispair units. Two slide switches provides On/Off operation and infinitely available speed settings

• Complete with ‘fan running’ indicator light

Xpelair Electrostatic Air Cleaners

The unit is to be supplied from the Xpelair EAC • The electrostatic filtration unit shall be • The grille pattern shall provide a wide range by Applied Energy Products Ltd. Morley suitable for surface, and recess mounting, coverage on ceilings Way, Peterborough PE2 9JJ. • Overall dimensions: Tel. +44 (0)1733 456789 • The unit shall be supplied with a remote W x H x D control to provide On/Off operation and EAC 400 485 x 273 x 739 variation in fan speed EAC 700 739 x 320 x 739 Model Ref EACF 400 570 x 343 x 572 • The electrostatic cell shall be manufactured Surface mounted in aluminium having filtration effective to • Class 1 Earthed appliance Airflow: 400 to 1000m3/h 0.01 microns. There shall additionally be a • Supply voltage: 220-240V 50Hz EAC400W White 89861AW pre-filter to capture general airborne particles EAC400K Black/woodgrain 89869AK • The unit shall have a status indicator panel Airflow: 1000 to 2000 m3/h and a 'wash' indicator panel LED shall EAC700W White 89862AW illuminate when the electrostatic cell and EAC700K Black/woodgrain 89870AK pre-filter require cleaning

• The casing of the surface models shall be Recess mounted manufactured in a polymeric material Airflow: 420 to 780m3/h • The flush model shall be of G.S.M. EACF400W Off White 90015AW construction with a pressed steel fascia Airflow: 1080 to 1500m3/h louvre coated studio finish off white, ready for painting to tone with ceiling décor

174 Xpelair Scimitar XPMS

The unit is to be supplied from the Xpelair • The fan shall be suitable for reverse operation • Customer connection shall be conveniently XPMS range by Applied Energy Products Ltd. located in an IP54 rated terminal box • The fan plate shall be manufactured from a located on the rear of the motor Morley Way, Peterborough PE2 9JJ. single steel pressing to ensure perfect form Tel. +44 (0)1733 456789 of the inlet bell mouth and uniformity of • The fans shall be suitable for use in ambient impeller tip clearance temperatures ranging from -30°C to +60°C and higher on selected models Model Ref • The fan body, impeller and motor housing XPMS315-12 91526AA shall be further protected from deterioration • All fans shall be supplied with an integral XPMS315-14 91527AA by coating with corrosion resistant powder inlet guard to EN294 coat finish XPMS355-14 91529AA • The fan shall be fully speed controllable XPMS400-14 91530AA • The motor shall be IP44 and IP54 rated using the appropriate speed controller or 5 XPMS400-16 91531AA external rotor type, AC capacitor start and step auto transformer (available as an XPMS450-14 91532AA run and have sealed for life ball bearings. ancillary) Terminals will be provided for connection to XPMS450-16 91533AA • Must be suitable for 220-240V IPH 50Hz an external thermal/overload protection device XPMS500-14 91534AA electrical supply XPMS500-16 91535AA • Insulation is to be rated to class F XPMS560-14 91536AA • Impellers shall be high efficiency, low noise XPMS560-16 91537AA pressed steel sickle blade design. Rotors and XPMS630-16 91539AA Impellers are to be dynamically balanced to ISO 1940-1:1986 Grade G 6.3

Xpelair Scimitar XSCS The unit is to be supplied from the Xpelair • The fan housing shall be manufactured from • Rotors and impellers are to be dynamically XSCS range by Applied Energy Products Ltd. galvanised steel. Drilled flanges shall be balanced to ISO 1940-1:1986 Grade G 6.3 provided at either end of the case Morley Way, Peterborough PE2 9JJ. • Customer connection shall be conveniently Tel. +44 (0)1733 456789 • The fan body, impeller and motor housing located in an IPX4 rated terminal box shall be further protected from deterioration attached to the body of the fan by two coats of corrosion resistant powder Model Ref coat finish • Terminals shall be provided within the terminal box for connection to an external XSCS315-12 91570AA • Motor mounting shall be via rigid welded thermal overload protection device XSCS315-14 91571AA steel rod construction and support the XSCS355-14 91573AA motor at four points • The fans shall be suitable for use in ambient XSCS400-14 91574AA temperatures ranging from –30°C to +60°C • The unit shall be capable of mounting at minimum and higher on selected models XSCS400-16 91575AA any angle or in any plane XSCS450-14 91576AA • The fan shall be fully speed controllable XSCS450-16 91577AA • The motor shall be IPX4 rated external rotor type, AC capacitor start and run and have using the appropriate speed controller or 5 XSCS500-14 91578AA sealed for life ball bearings and inbuilt step auto transformer (available as an XSCS500-16 91579AA thermal protection. Insulation is to class F ancillary) XSCS560-14 91580AA • Impellers shall be high efficiency, low noise • Must be suitable for 220-240V IPH 50Hz XSCS560-16 91581AA pressed steel sickle blade design electrical supply XSCS630-16 91583AA

Xpelair Rapier XPMA n o The unit is to be supplied from the Xpelair • The fan shall be suitable for reverse operation • Rotors and impellers are to be dynamically i t balanced to ISO 1940-1:1986 Grade G 6.3

XPMA range by Applied Energy Products Ltd. a • The fan plate shall be manufactured from a

Morley Way, Peterborough PE2 9JJ. single steel pressing to ensure perfect form • Customer connection shall be conveniently c i

Tel. +44 (0)1733 456789 of the inlet bell mouth and uniformity of located in an IP54 rated terminal box f i impeller tip clearance located on the rear of the motor c

Model Ref • The fan body, impeller and motor housing • The fans shall be suitable for use in ambient e

XPMA315-12 91540AA shall be further protected from deterioration temperatures ranging from -30°C to +60°C p

XPMA315-14 91541AA by coating with corrosion resistant powder and higher on selected models S coat finish XPMA355-14 91543AA • All fans shall be supplied with an integral l XPMA400-14 91545AA • The motor shall be IP44 and IP54 rated inlet guard to EN294 a

external rotor type, AC capacitor start and c XPMA400-16 91546AA i • The fan shall be fully speed controllable run and have sealed for life ball bearings. XPMA450-14 91547AA using the appropriate speed controller or 5 p Terminals will be provided for connection to XPMA450-16 91548AA step auto transformer (available as an y an external thermal/overload protection device XPMA500-14 91040AA ancillary) T

XPMA500-16 91549AA • Insulation is to be rated to class F r

• Must be suitable for 220-240V IPH 50Hz i XPMA560-16 91550AA

• Impellers shall be high efficiency, low noise electrical supply a XPMA630-16 91050AA pressed steel sickle blade design l

XPMA710-16 91055AA e p X www.xpelair.co.uk 175 Xpelair Typical Specification

Xpelair Rapier XSCA

The unit is to be supplied from the Xpelair • The fan housing shall be manufactured from • Customer connection shall be conveniently XSCA range by Applied Energy Products Ltd. galvanised steel. Drilled flanges shall be located in an IPX4 rated terminal box provided at either end of the case Morley Way, Peterborough PE2 9JJ. attached to the body of the fan Tel. +44 (0)1733 456789 • The fan body, impeller and motor housing • Terminals shall be provided within the shall be further protected from deterioration terminal box for connection to an external Model Ref by two coats of corrosion resistant powder thermal overload protection device coat finish XSCA315-12 91584AA • The fans shall be suitable for use in ambient • Motor mounting shall be via rigid welded temperatures ranging from –30°C to +60°C XSCA315-14 91585AA steel rod construction and support the minimum and higher on selected models XSCA355-14 91587AA motor at four points XSCA400-14 91589AA • The unit shall be capable of mounting at • The fan shall be fully speed controllable XSCA400-16 91590AA any angle or in any plane using the appropriate speed controller or 5 step auto transformer (available as an XSCA450-14 91591AA • The motor shall be IPX4 rated external rotor ancillary) XSCA450-16 91592AA type, AC capacitor start and run and have sealed for life ball bearings and inbuilt • Suitable for 220-240V XSCA500-14 91078AA thermal protection. Insulation is to class F

XSCA500-16 91593AA • Impellers shall be high efficiency, low noise XSCA560-16 91594AA pressed steel sickle blade design XSCA630-16 91595AA • Rotors and impellers are to be dynamically XSCA710-16 91597AA balanced to ISO 1940-1:1986 Grade G 6.3

Xpelair Rapier Roof XRA

The unit is to be supplied from the Xpelair XRA • The roof cowl assembly shall be • Insulation rating shall be class F. Impellers range by Applied Energy Products Ltd. Morley manufactured in glassfibre with a UV shall be high efficiency, low noise pressed Way, Peterborough PE2 9JJ. stabilised external finish steel sickle design for sizes 315 to 450mm and die cast aluminium aerofoil section for Tel. +44 (0)1733 456789 • The assembly shall include a birdguard and sizes 500 and 630mm holes for fixing to the roof upstand (constructed by others) • Rotors and impellers shall be dynamically Model Ref balanced to ISO 1940 - 1.1986 Grade G 6.3 • The fan plate and bellmouth assembly shall XRA315-12 91997AA be manufactured from a single steel • Customer connection shall be conveniently XRA350-14 91998AA pressing to ensure perfect form and positioned in a IPX4 terminal box uniformity of impeller tip clearance XRA400-14 91999AA • The fan shall be suitable for use in ambient XRA450-14 92000AA • The fan body, impeller and motor housing temperatures ranging from -30ºC to +60ºC XRA500-16 92001AA shall be further protected from deterioration and higher on selected models by coating with corrosion resistant powder • The fan section shall have an integral inlet XRA630-16 91340AA coat finish guard to EN294 • The motor shall be IP54 rated on sizes 500 • The fan shall be fully speed controllable and 630mm and IP44 rated on 315 - 450mm. using the appropriate optional electronic external rotor motor type, AC capacitor start speed controller or 5 step auto transformer and run and have sealed for life bearings

• Terminals shall be provided for connection to • Suitable for 220-240V an external thermal overload protection device

Xpelair XMV

The unit is to be supplied from the Xpelair XMV • The motor shall be speed controllable using • The casing and twin wall body assembly range by Applied Energy Products Ltd. Morley a five step transformer and DOL starter shall be manufactured in high density Polyethylene and coloured RAL 9002 beige Way, Peterborough PE2 9JJ. • The models shall be available for single or Tel. +44 (0)1733 456789 three phase operation and in 4 and 6 pole • The unit shall be 100% recyclable

• The unit shall be designed for installation in • A service isolator shall be provided on • A full range of optional five step the horizontal plane on a suitable roof curb the unit transformers and starters shall be available or purlin box (supplied by others) for all models • The impeller shall be of aluminium • The unit shall be designed for the extraction construction with polyamide blades • Suitable for 220-240V of air with temperatures up to 100ºC • A discharge birdguard shall be provided • The motor shall be located out of the airstream and be suitable for external ambient temperatures from -30ºC to +40ºC

176 Xpelair XID

The unit is to be supplied from the Xpelair XID • The fan housing shall be manufactured from • External terminal connection box zinc coated sheet steel with integral bell range by Applied Energy Products Ltd. Morley • The capacitor shall be mounted out of the mouth inlet & down stream guidevanes Way, Peterborough PE2 9JJ. airstream and housed within the customer Tel. +44 (0)1733 456789 • The duct connection spigot shall be 30mm connection terminal box located on the deep minimum to facilitate secure connection fan body of the ductwork • The fans shall be suitable for use in ambient Model Ref • The fan shall be supplied complete with a temperatures ranging from –30°C to +50°C XID100 90101AA universal mounting bracket • The fan shall be fully speed controllable XID125 90102AA • The unit shall be capable of mounting at any using the XIC1 speed controller (available as XID150 90103AA angle or in any plane an ancillary Ref. 21858AW) XID200 90104AA • Motors shall be IP44 rated external rotor type, • Must be suitable for 220V-240V XID250 90208AA AC capacitor start and run and have sealed for life ball bearings and inbuilt thermal XID315 90106AA protection. Insulation is to be rated to class F

• Impellers are to be backward curved centrifugal and dynamically balanced to ISO 1940-1:1986 Grade G 6.3

Xpelair XIDP

The unit is to be supplied from the Xpelair XIDP • The fan shall be suitable for use with rigid or • The capacitor shall be mounted out of the range by Applied Energy Products Ltd. Morley flexible ductwork airstream and located on the fan body Way, Peterborough PE2 9JJ. • The housing shall be manufactured in a an • The fan shall be suitable for use in ambient Tel. +44 (0)1733 456789 impact resistant and fire retardant polymer temperatures from -30ºC to +50ºC with integral bell mouth entry, guidevanes • The fan unit shall be fully speed controllable and terminal connection box using XIC1 speed controller available as Model Ref • The fan shall be supplied with universal an ancillary XIDP100 91383AA mounting bracket. The unit shall be capable • Must be suitable for 220V-240V XIDP125 91384AA of being mounted at any angle and in any plane XIDP150 91385AA XIDP200 91386AA • Motors shall be IP44 rated external rotor type, AC capacitor start and run and have sealed XIDP250 91387AA for life ball bearings and inbuilt thermal XIDP315 91388AA protection. Insulation is to be rated to class F • Impellers shall be backward curved centrifugal, dynamically balanced to ISO 1940:1986 Grade G 6.3

Xpelair Xpress XPRS n o The unit is to be supplied from the Xpelair • The inline fan shall have a pressure • Wiring to the outside of the unit shall to to a i t Xpress range by Applied Energy Products Ltd. characteristic up to 250% higher than a terminal box rated at IP44 a conventional unit Morley Way, Peterborough PE2 9JJ. Tel. +44 • The fan diameter shall be no bigger than the c i

(0)1733 456789 • The fan shall have a steel housing with duct in which it will be installed f a contoured bellmouth entry and i

• The fan shall be speed controllable using a c integrated foot Five step auto transformer Model Ref e • The mixed flow fan blade shall be fabricated • Must be suitable for 220V-240V p XPRS250 91498AA and balanced on the hub assembly to G 2.5 S XPRS315 91499AA ISO 1940. There shall be matching aerofoil section guidevanes l

XPRS355 91500AA a

XPRS355+ 91501AA • The motor shall be a continuously rated c capacitor start and run motor with integrated i

thermal overload protection p y T r i a l e p X www.xpelair.co.uk 177 Xpelair Typical Specification

Xpelair MinimX C XCDF

The unit is to be supplied from the Xpelair • Pressure developing low profile inline fans • Bearings shall be lubricated for life. MinimX C range by Applied Energy Products with hinged ‘swing out’ motor/impeller panel IP44 protection for periodic inspection and service access Ltd. Morley Way, Peterborough PE2 9JJ. Tel. • The fan shall be fitted with a terminal box +44 (0)1733 456789 • Casing shall be manufactured in galvanised incorporating knock outs and one cable entry sheet metal with 20mm spigot flanges and gland rated IP44 integral first-fit key hole mounting slots • Must be suitable for 220V-240V Model Ref • Motor shall be continuously rated two pole of XCDF100 91502AA external rotor motor / fan assembly design XCDF125 91503AA balanced in two planes to DIN ISO 1940. Insulation shall be IP44 Class F with thermal XCDF150 91504AA overload protection XCDF200 91505AA XCDF250 91506AA XCDF315 91507AA

Xpelair LoSound C LQTC

The unit is to be supplied from the Xpelair • The casing shall be manufactured in • The IP44 Class F capacitor start and run LoSound range by Applied Energy Products galvanised sheet metal with integral keyhole motor shall be rated for continuous running fixing points Ltd. Morley Way, Peterborough PE2 9JJ. • A 3m three core flexible cord shall be Tel. +44 (0)1733 456789 • The casing shall be lined on four sides with provided with the unit 40mm faced attenuation material

• The unit shall be provided with a removable Model Ref cover with quick release catches for periodic LQTC125 91989AA inspection and cleaning

LQTC150 91990AA • External rotor motor and forward curved LQTC200 91991AA centrifugal fan assembly shall be balanced in LQTC250 91992AA two planes to DINISO 1940 LQTC315 91993AA • The motor shall be maintenance free with sealed for life bearings, and integral thermal LQTC355 91994AA overload protection

Xpelair CubeX CMAX CBXC

The unit is to be supplied from the Xpelair • Unit casings shall be constructed from • Speed control shall be through an optional CBXC range by Applied Energy Products Ltd. galvanised sheet metal using a frameless variable voltage device construction method. The casing shall be Morley Way, Peterborough PE2 9JJ. • Centrifugal impeller motor rating IP55 Class F double skin with the addition of 40mm of Tel. +44 (0)1733 456789 sound attenuating insulation, the casing shall be available with a choice of two spigot sizes for adaption to site ductwork Model Ref CBXC280S315 91508AA • Fan shall he high efficiency backward curved with matched external rotor. The motor shall CBXC280S355 91509AA be fitted with sealed for life bearings and be CBXC315S315 91510AA fitted with Thermal overload protection to the CBXC315S355 91512AA terminal block with full motor protection through an external tripping device CBXC355S315 91513AA CBXC355S355 91514AA CBXC400S400 91515AA CBXC400S450 91516AA

178 Xpelair HiFlo CMAX XSFA

The unit is to be supplied from the Xpelair XSFA • Unit casings shall be manufactured from best • Fans shall be mounted individually onto fan range by Applied Energy Products Ltd. Morley quality galvanised sheet steel with access decks to facilitate easy removal Way, Peterborough PE2 9JJ. from top or bottom • Motors shall be totally enclosed, high- Tel. +44 (0)1733 456789 • Reinforced slotted safety fixing points shall efficiency, split-capacitor type with power be incorporated to facilitate drop-rods or factors of better than 0.9. Maximum ambient mounting bolts within overall unit width operating temp. 40°C Model Ref XSFA100 91389AA • All permanent fixings shall be rivetted and all • Bearings shall be sealed-for-life, XSFA125 91390AA removable items shall be retained via maintenance-free, ball bearing type with a setscrews and nutserts minimum life expectancy of 50,000 hours XSFA150 91391AA under design operating conditions XSFA200 91392AA • Acoustic insulation shall be self adhesive XSFA250 91393AA foam construction meeting Class 0 rating • Insulation shall be to Class ‘B’ or ‘F’ with to BS476 Parts 6 and 7 to minimise enclosure to IP44 XSFA315 91394AA noise breakout XSFA315+ 91395AA • The fan shall be fully speed controllable using XSFA400 91396AA • Fans shall be single-inlet, single width, or the appropriate optional electronic speed double-inlet, double-width, centrifugal type controller or 5 step auto transformer XSFA400+ 91397AA with high efficiency, low noise, forward- curved, multiblade galvanised sheet steel • Single fan unit impellers housed within galvanised steel scrolls • Must be suitable for 220V-240V • Motor/impeller assemblies shall be statically and dynamically balanced, in two planes, in accordance with BS 5265, Part 1, 1979 to G2.5

Xpelair ManCoolers

The unit is to be supplied from the Xpelair • The floor standing units shall be supplied ManCooler range by Applied Energy Products complete with robust tubular stand for fast Ltd. Morley Way, Peterborough PE2 9JJ. set up on site

Tel. +44 (0)1733 456789 • The casing shall be adjustable and capable of being locked at the desired angle of operation Model Ref • The motor shall be totally enclosed with ManCooler maintenance free sealed for life bearings MC350 91408AA and safety thermal overload protection

MC400 91409AA • The impeller shall comprise of a central hub MC400 110V 92309AA with fully adjustable high performance MC450 91410AA blades aerofoil blades

MC560 91411AA • Finger guards to DIN24167 (UNE 20-359- n

74) shall be fitted to each end of the casing o i

Trapeze with bolted fixings t

TP450 91412AA • The terminal box shall be no less than IP55 a c

• The Trapeze model shall additionally be i f

available for suspension at high level using i

four steel suspension eyes provided c e p S l a c i p y T r i a l e p X www.xpelair.co.uk 179 Xpelair Wiring Diagrams

Xpelair Premier DX180 & DX180T/H

Premier DX180 Premier DX180T/H

Xpelair Premier DX200 & DX200T

Premier DX200 Premier DX200T

Xpelair Premier CF20 & CF20T

Premier CF20 Premier CF20T

Xpelair Premier LoVolt DX200 & LoVolt CF20

Premier LoVolt DX200T Premier LoVolt CF20 Premier LoVolt CF20T

Xpelair Premier LVCF20T DC

PremierLVCF20T CF20 DC Diagram 1 Use for intermittent ventilation of bathrooms, continuous ventilation of bathrooms, utility rooms and WCs

Diagram 2 Use for continuous ventilation of kitchens

Diagram 3 Use for intermittent ventilation of WCs

PremierLVCF20T CF20 DC PremierLVCF20T CF20 DC

180 Xpelair Premier CF20T/40T CV

Diagram 1 Use for intermittent ventilation of kitchens, utility rooms and bathrooms

Diagram 2 Use for intermittent ventilation of internal rooms

Diagram 3 Use for intermittent ventilation of sanitary rooms

Xpelair DX100 & XX100

DX100/PC/HP/PIR/XX100/P DX100T/H/XX100T

Xpelair LoVolt LV100

LV100/PC/H/HP/PIR LV100T

Xpelair Slimline SL100, SL100P & SL100T/HT

Slimline SL100 Slimline SL100P

Slimline SL100T/HT

Xpelair CentrX

CentrX CT100/100+/100+P CentrX CT100T/HT/100+HT Xpelair Wiring Diagrams www.xpelair.co.uk 181 Xpelair Wiring Diagrams

Xpelair XIL Inline shower fan systems

XIL100/125/150/XXS100 XIL100T/125T/150T/XXS100T

Xpelair BriteX LoVolt & BriteX Turbo

BX100W/C/BX100+W/C BX100WT/CT/BX100+WT/CT

Xpelair XIM

XIM100 XIM100T

XIM150/200/100+/125 XIM150T/XIM150+T

Xpelair Slimline 150

Slimline SL150 Slimline SL150P

Slimline SL150HT

182 Xpelair GX6, GXC6 & GXC9

GX6 GXC6, GXC6T, GXC6SC & GXC9

Xpelair Premier DX400 & CF40

DX400 DX400PC

DX400T/CF40/CF40TD DX400RS/CF40RSTD

Xpelair Nouvelle Cuisine Xpelair CX10 & CMF

Kitchen Canopies CX10/CMF

Xpelair Xplus

Xplus275/340 Xplus275/340 with 3 speed switch s m a r g a i D g n i r i W r i a l e p X www.xpelair.co.uk 183 Xpelair Wiring Diagrams

Xpelair Xplus 250 & 400 DC 8CV

Xplus250/400

Xplus250/400 with 3 speed switch

Xpelair Xcell 150 Longlife

Xcell 150

Xpelair Xcell 200 Longlife

Xcell 200 Xcell 200BP

184 Xpelair Xcell 270 Longlife

Xcell 270

Xpelair Xcell 300 & 400 Longlife

Xcell 300/400

Xpelair Xcell 600 Longlife

Xcell 600 Xcell 600BP s m a r g a

Xpelair EverDri LongLife Xpelair LoVolt XHR150 i D

EverDri XEDW/XEDL XHR 150 g n i r i W r i a l e p X www.xpelair.co.uk 185 Xpelair Wiring Diagrams

Xpelair GX6, GX9 & GX12

GX6 GX9/GX12

Xpelair PX6, PX9 & PX12

PX6 PX9/PX12

Xpelair RX6, RX9 & RX12

RX6 RX9/RX12

Xpelair WX6, WX9 & WX12

WX6 WX6T

WX9/WX12

186 Xpelair ChefX

ChefX Tempo/Presto/Mezzo

Xpelair WH30 & WHP30

WH30 WH30 with HC301

WHP30 with HC301

Xpelair WH60

WH60-single phase WH60-3 phase using a 240V contactor coil s

WH60-3 phase using a 415V contactor coil m a r g a i D g n i r i W r i a l e p X www.xpelair.co.uk 187 Xpelair Wiring Diagrams

Xpelair ScreenHeat & PlinthHeat

PlinthHeat with integral controls PlinthHeat with remote control

Xpelair Whispair

NWAN

Xpelair XPMS, XPMA & XRA

315/350/400 450

500/630 315/350/400 with XCW controller

450 with XCW controller 500/630 with XCW controller

188 Xpelair XSCS & XSCA

Xpelair XMV

Single phase 3 phase

Xpelair XID & XIDP

XID/XIDP XID/XIDP with XIC1 speed controller

Xpelair LoSound XSFA

XSFA s m a r g a i D g n i r i W r i a l e p X www.xpelair.co.uk 189 Your guide to a successful fan installation

We take the air that surrounds us for granted and yet small changes in for example - air purity, temperature, humidity and velocity - can effect our performance and at worst make us ill. Designing a ventilation system can in most cases be easily achieved by following the step by step approach described below. However, if the space or the activity is unusual, call in the experts - Xpelair who will be happy to advise and assist in proposing the most appropriate scheme.

Choosing a Ventilation Solution 2. Calculate performance requirement Air Replacement Multiply room volume by the number of The type of system chosen will be air changes appropriate to the room A tight fitting door can prevent a fan from dependant on the application and type from the guide table opposite. receiving adequate air replacement. building layout. A ventilation system A suitable gap between the underside of requires as even a flow of air across an Example continued: Recommended Air the door and the floor finish is usually area as possible. The most cost effective Changes Per Hour for domestic adequate for toilets and bathrooms method of achieving this is by extract kitchens is 10 to 15. 18m3 x 10 ACH - although Xpelair Slimline privacy air ventilation with appropriate air 180m3/h, 18m3 x 15 ACH = 270m3/h. transfer grilles are available. For larger replacement provision. extract volumes air replacement should Therefore a fan with an extract be carefully considered particularly in In the leisure industry input ventilation is performance between 180-270m3 is tightly sealed properties. preferred with air escaping from the appropriate. NOTE: it is always better Fuel Burning Appliances premises through doors and other to pick a fan at the higher end of the available openings. Many schemes use range rather than risk unsatisfactory Where a fuel appliance is fitted with a non both extract and intake fans which are ventilation. balanced , adequate air replacement often connected to a single control must be provided to prevent fumes being system. For fully automatic operation, a 3. Select your fans from the product drawn down the flue when the fan is range of sensors are available which will extract performance table opposite operating at its maximum performance. switch On immediately when required Example continued: selection might Refer to Building Regulations for specific but only when necessary for energy be a GX6 product: 266m3/h, DX400 requirements. Exhaust air must not be efficiency. or CF40: 245m3/h or a Kitchen discharged into a flue used for exhausting canopy: 350m3/h. fumes from applications supplied with 1. Calculate room volume energy other than electricity. Take measurements in metres. Further Considerations Intake fans or air replacement grilles Window, wall, ceiling or roof? should be sited well away from the flue to ensure that gases are not For effective operation the extract point reintroduced into the building. See should be as far away from the source of Building Regulations. air replacement - usually the door, and as close to the source of condensation or Splash Areas smells as possible. An electrical product in a bathroom or This usually determines the type of fan showeroom must be situated in (window, wall etc.) If the room has no accordance with IEE zoning requirements. For additional safety opening windows then a model fitted with Xpelair LoVolt SELV products operating an overrun timer will meet the requirements at 12 volts should be considered. of the building regulations. Multiply: General For automatic control choose from the Length x Width x Height = Room m3. convenience of an optional Xpelair When determining the method of humidity or PIR sensor. Example: ventilation and flow rates the A domestic kitchen 3m x 2.5m x requirements of all authorities concerned 2.4m = 18m3 must be observed.

190 Air change requirements Product Extract Performance

Situation (ach) Product Extract Performance (m3/h) Assembly Rooms* 6 - 10 min max Bakeries* 20 - 30 DX180, DX200 & CF20 36 108 Banks/Building Societies* 6 LVDX200 & LVCF20 36 108 Banquet Halls* 10 - 15 DX100 & XX100 76 Bathrooms 6 - 8 LV100 85 Bedrooms 2 - 4 SL100 & SL150 67 218 Billiard Rooms 6 - 8 CT100 & CT100+ 62 169 Rooms* 15 - 30 XIL & XXS 46 133 Cafés and Coffee Bars* 10 - 15 BriteX LoVolt & Turbo 56 74 Canteens* 8 - 12 XIM 77 845 Cellars 3 - 10 GX6, GXC6 & GXC9 83 549 Churches 1 - 3 DX400 & CF40 61 250 Cinemas and Theatres* 6 - 10 Nouvelle Cuisine 200 851 Club Rooms 8 - 10 CX10 & CMF 63 329 Rooms 10 - 20 Xplus 18 493 Conference Rooms* 6 - 10 Xcell 270 110 290 Dairies 8 - 10 Xcell 300 & 400 100 400 Dance Halls 12 EverDri 43 259 Dye Works 20 - 30 XRH150 12 31 Electroplating Shops 10 - 12 GX6, GX9 & GX12 266 1614 Engine Rooms* 15 - 30 WX6, WX9 & WX12 246 1715 Entrance Halls, Corridors 3 - 5 PX6, PX9 & PX12 246 1712 Factories and Workshops 6 - 10 RX6, RX9 & RX12 206 1100 Foundries 15 - 30 ChefX 400 2800 Garages* 6 - 10

Glass houses* 45 - 60 Product Extract Performance (m3/s) n

min max o Gymnasiums 6 i Hairdressing Salons 10 - 15 XPMA/XPMS 0.68 3.35 t a

Hospitals - Sterilising Wards* DHSS Guidance XSCA 0.61 3.61 l l Hotel Bars 6 - 10 XRMA 0.61 2.95 a

Kitchens - Hotel or Industrial* DWIT2 30 - 40 XMV 0.53 2.47 t Kitchens - Domestic 10 - 15 XDRA Twin 0.07 1.05 s n

Laboratories* 4 - 15 XID 0.08 0.46 i Launderettes 10 - 15 XIDP 0.07 0.38 n Laundries* 10 - 15 XSFA 0.07 1.05 a

Lecture Theatres* 6 - 10 XDFA Twin 0.07 1.05 f Libraries* 3 - 4 l u

Living Rooms 4 - 6 f

Mushroom Houses 6 - 10 s

Offices* 4 - 6 Airflow Performance s Photo and X-ray Darkrooms* 6 - 8 e Public House Bars 12 - 15 Product Airflow (m3/h) c c Recording Studios 10 - 12 min max u Restaurants* 10 - 15 Digitemp 350 390 s Schoolrooms* Building Bulletin 101 2005 8.3 l/s/Person WH30, WH60, WHP30 & DCH3000A 115 311

Shops and Supermarkets 8 - 10 ScreenHeat & PlinthHeat 110 250 a Shower/Bathrooms 15 - 20 SweepFan 8761 13959 o Stores and Warehouses 3 - 6 Electrostatic Air Cleaners 400 2000 t

Squash Courts 4 - 6 DigiPure 763 3276 e

Toilets (Public)* 5 min / 6 l/s/Pan d i Toilets (Domestic) 6 - 10 Product Airflow (m3/s) u Utility Rooms 15 - 20 min max g Welding Shops (General Extract) 15 - 30 ManCoolers 0.86 3.06 r

*Taken from CIBSE Guide, B2:2001 with their kind permission u o

www.xpelair.co.uk 191 Y

Service and Design Solutions

When buying Xpelair products, you already know that they will be of the highest quality and will provide many years of trouble-free operation.

However, for peace of mind, Xpelair’s after sales service is second to none. Products are covered by a full parts and labour guarantee from the date of purchase, so should the product become faulty within the guarantee period, it will be repaired by our dedicated service engineers, totally free of charge. As market leader, Xpelair prides itself on engineering excellence and the range of services offered to customers - Subject to the terms of Xpelair’s guarantee.

Application Design Technical Services Export

A design service is available to Our Technical Services Call Centre is Xpelair is a great British brand in every customers wishing to use Xpelair products staffed by a team trained in diagnosing and sense of the word but for many years it in their building projects. Design work can rectifying potential concerns over the has been a world leader in the ventilation be carried out from scaled architect’s phone, whether or not the product you and air quality markets with sales in plans (1:500 min) construction and have purchased is in guarantee. If for any excess of fifty countries world-wide. insulation data of the property, ventilation reason they are unable to solve the Xpelair has achieved this by taking into requirements etc. should be supplied with problem by phone, they will brief an consideration global market requirements any request for design work. engineer, prior to the visit, to ensure that and ensuring products are developed to wherever possible, the problem is fixed first meet these needs, as well as developing • Consultation to select the optimum time. The team also provides advice on products for specific countries and design and product specification of application, installation and operation, regions, taking into consideration the job ensuring that the customer receives the full approvals, electrical supply and climate. benefit from purchasing an Xpelair product. • Designs that meet both building Tel: +44(0)1733 456 737 and health & safety regulations Tel: 08709 000430 Fax: +44(0)1733 456 727 where required Fax: 08709 000530

• Sizing and selection of products to your own or national specification Spares requirements Regular maintenance and servicing of • Estimated operating and Xpelair products is recommended to equipment costs ensure the longevity of your Xpelair product. From time to time it may be Tel: 01782 385779 necessary to replace components to Fax: 01782 385893 extend the life of the product.

Xpelair provide a wide range of spare parts covering current and previous products, making maintenance simple and effective.

Tel: 08700 102829

192 Glossary of Terms

AC - Alternating current G.S.M. - Galvanised sheet metal Often referred to as positive pressure ventilation. Pressurises a building driving air ACH - Air changes per hour. The House Dust Mite Genus out through gaps in the . number of times the volume of air in a Dermatphagiodes - skin eater. room needs to be changed in one hour Species: pteronyssinus. RH - Relative humidity. The ratio of the depending on the activity in that space. Arachnids about 0.2 - 0.3mm long. amount of water in the air at that Normally given as a range e.g. 15-20 ach Habitat: bedrooms and family rooms temperature. Expressed as a % RH. UK based on the level of usage. where shed skin flakes and warm moist outside humidity levels are regularly conditions are present. Because they are between 60-70%RH. Indoors with heating Amps FLC - Full Load Current. Current heavily contaminated with faecal pellets, and appropriate ventilation a level of at normal fan/motor running speed. dust mites are identified as allergenic between 60 - 40% is most comfortable. material linked to asthmatic eczema, See also Condensation. Amps SC - Starting Current. This is hayfever and other allergic conditions. higher than amps FLC. Controllers and R.P.M.- Revolutions per minute starters need to be sized accordingly. IEE Regulations - Publication of the Institute of Electrical Engineers. Also Sensor Control - Fan switch activated Axial - Propeller Fan. Draws air from known as BS 7671. A safe and best by a change in selected ambient condition behind the blade to the front. Ideal for low practice document used throughout the e.g. humidity, temperature etc. pressure applications and expelling electrical installation industry. directly to the outside. SELV - Safety Extra Low Voltage IP Rating - Classification of degrees of Often referred to as separated low Building Regulations Documents - protection for an electrical product voltage. Used to describe fans operating Documents approved by the Secretary of developed by CENELEC. First digit under 50V (usually 12V AC). State as guidance to meeting the Building describes degree of protection from solids, Regulations 1991. Part F1: ventilation to the second from liquids. Examples: IP44 Temperature - Shown in this publication the living space; Part C: the structure; and 1st digit: protected against solid objects in degrees Centigrade (or Celcius). Ideal

Part J: provision of air for fuel burning over 1mm. 2nd digit: protected against target temperatures for ventilation design s appliances; Part L: improvement to energy sprays from all directions. IPX7 1st digit not are: efficiency and reduction of CO2 emissions. tested or not relevant. 2nd digit: protected Summer: between 19 and 24ºC m against the effects of temporary immersion Winter: between 18 and 23ºC r

European Committee for e CENELEC - between 15cm and 1m of water.

Electrical Standardisation Thermal Overload Protection - A T

l/s litres per second - Measurement of safety component designed to interrupt f Centrifugal - Also known as radial fans volume flow. the current to a motor before the windings Used where a high total pressure is exceed their design operating o required. Ideal for longer ducting runs.

LoVolt - Term used to describe SELV temperature. Types: One shot - acts like a y

12V product. fuse and cannot be reset. Self-resetting - r Condensation - In Buildings. Small water

reconnects the current when the a droplets forming where air with high RH has 3 temperature returns to an acceptable

m /h Cubic metres per hour - s contact with a cold surface (e.g. a mirror). Measurement of volume flow rate level. Manual reset - usually fitted to industrial fans and is a requirement for s

Conversion factor - Used to convert 3 o

m /s Cubic metres per second - inline duct fans; requires manual resetting. l from one set of units to another e.g. 1 l/s x Measurement of volume flow rate 3.6=m3/h. Transformer Control - Provides a G MEV - Mechanical extract ventilation. A number of fixed voltage outputs to vary the dB(A) - Unit of sound measurement

central extract unit drawing air from speed of speed controllable fan motors. d based on pressure measurements taken several extract points and discharging Available in single phase and 3 phase. at 8 octave bands. Sound diminishes as n though a single outlet. distances from the sound source increase. a UV stabilised - Additive or treatment Micron - Measurement equal to one designed to counter the deteriorating DC Motor - Direct current motor. DC s millionth of a metre or one thousandth effects of ultraviolet radiation from strong

motors used in Xpelair fan products have n an electronics interface which allows them of a millimetre. sunlight. o to be connected to a normal AC supply. i

Radial impeller with a VOC - Volatile Organic Compound t DC motors consume less electrical power, Mixed Flow - static pressure increase over an axial An organic chemical. Used in a wide run cooler and therefore have an extended u blade design. Ideal for longer duct runs or range of products: paints, varnishes, l life expectancy.

direct extraction of air in exposed areas. solvents, wax, disinfectants, cosmetics, o aerosol sprays, insect repellents, air

Part F1 - Refers to approved Part F1 S 'Means of Ventilation' in domestic and non- Motor Insulation Class - (B or F) Motor fresheners, dry cleaned clothing, insulation system classification indicating degreasers and fuels. Can cause ill domestic building. n F1: means of ventilation. the maximum motor working temperature health effects. for normal motor-life expectancy. g i Watt - Unit of power equal to one Joule Document L - Refers to Approved s Document L ' Conservation of fuel and m/s - metres per second. Air velocity per second. Power ratings of products are e power'. Compliance reduces the levels of or speed. quoted in Watts. One kW is 1000W natural air change. e.g. 1.2 kW = 1200W. D MVHR - Mechanical ventilation with heat recovery. Xcell - Heat recovery cell made of thin FID - Free air discharge. Performance d without any system resistance. membrane polymeric or non-ferrous Pa - Unit of pressure (Pascal) for materials. Allows two separated streams n Filter classes - measuring system resistance or static of air to pass through the cell, giving up a Coarse filter EU1 - EU4 pressure. 1 Pa = 0.10mm H2O. extracted heat to the incoming fresh air Fine filter EU5 - EU9 flow, whilst reducing its relative humidity. e

PVS - Positive ventilation system c

Absolute filter EU10 - EU14 i v r e

www.xpelair.co.uk 193 S UK Sales Sales Hotline: 08709 000420 Sales Fax: 08709 000520

International Sales Sales Hotline: +44 (0) 1733 456737 Sales Fax: +44 (0) 1733 456727

Technical Services Techline: 08709 000430 Techfax: 08709 000530

Brochure Hotline Telephone: 08709 000540

Xpelair Morley Way Peterborough UK PE2 9JJ t +44 (0) 1733 456789 Xpelair is a registered trademark of Applied Energy Products Ltd. f +44 (0) 1733 310606 Applied Energy Products reserve the right to alter product specification or www.xpelair.co.uk appearance without prior notice. All finishes in the brochure are as accurate as printing processes allow.

X056 January 2008 Applied Energy Products. All rights reserved.