Lounge Tech Spec., Revised 9/6/2016

THE LOUNGE ‘BIBLE’

W elcome to the Lounge

MAIN POINTS TO NOTE:

The venue is supplied without a show operator.

The front of house manager on duty is not available for the performance of any cue. This includes but is not limited to operating the house lights etc. at the top of the show.

A technician familiar with the venue can be booked for £15/ hr +VAT for a minimum of 4 hours.

Please Note: this document is intended to be as complete and clear as possible. If (after reading all the information provided) you are still not sure how to achieve what you want to; then you will need to employ an operator.

Shows are responsible for providing their own risk assessments and relevant insurance.

You must inform the when booking if you intend your performance to include fire, weapons, smoke, strobe or other hazards.

There are frequently as many as four shows per night in the Lounge.

Please remember that is shared and ALWAYS leave it tidy and clean.

It will be necessary to plan your performance including turnaround time to allow access for other companies using the space. You will be advised of the times you will have access and when you need to be clear of the venue on each night of your run.

It is not possible to alter the standard lighting and sound rig though you may bring in your own lanterns or use our additional lighting stock. i.e.:

You may not refocus any lantern that you did not rig yourself.

Please provide the theatre with a list of all lighting or sound equipment or set that you bring into the venue.

The lighting and sound desks and patches must be returned to default at the end of each and every performance.

Please return all equipment to the appropriate place after your show.

Any damage caused to the theatre or equipment may be recharged.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

Enquiries about booking or artistic policy should be directed to Jo Rigg. [email protected] 020 7534 1740

Enquiries about marketing should be directed to Helen Young. [email protected] 020 7534 1740

Enquiries about ticketing should be directed to: [email protected] 020 7734 2222

Lounge Tech Spec., Revised 9/6/2016

SAFETY:

This bit is IMPORTANT!

As specified at the booking stage; you should provide adequate insurance to indemnify yourselves and the theatre against all claims in respect of any incidents relating to the booking.

A comprehensive risk assessment and a signed copy of the theatre’s Health & Safety Rules must be provided to the theatre at least 4 weeks in advance of the show

The theatre reserves the right to cancel any activity or performance should it be deemed that is inadequately insured, is unsafe to the public or that presents high risk of public injury.

You and all your staff and performers must abide by the health and safety policies of the theatre at all times.

All electrical equipment plugged into the mains electricity supply must carry a Portable Appliance Test (“PAT”) certificate and must be safe and suitable for use in public spaces.

All set, costume and props brought into the venue must be adequately fireproofed.

You must inform the Theatre when booking if you intend the performance to include fire, weapons, smoke, strobe or other hazards. Any use of flame or effects must be approved by the council 4 weeks in advance of the show.

If you would like to bring any set or equipment into the venue, please make lists and plans available to the venue at least 4 weeks prior to the first performance. Technical arrangements not agreed in advance may not be able to be accommodated.

Please read, sign and return the attached:

 Health & Safety Rules  Risk Assessment Questionnaire

to [email protected] immediately if you have not already done so.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

2

Lounge Tech Spec., Revised 9/6/2016 ADDRESS:

The Lounge @ Theatre 6 Leicester Place WC2H 7BX

GET IN:

For loading & unloading of vehicles, the only entrance to the venue is on Leicester Place. Leicester Place is closed to all traffic at any time unless you have special dispensation.

There are three ways to arrive at the venue: You may drive on to Lisle Street between 00:00 and 07:00 though you may not stop. Between 07:00 and 12:00 you may stop at the top of Leicester Place about 30m (35 yards) from the front door of the theatre. Or, between 06:00 and 10:00 Monday to Saturday you may drive onto Leicester Square and up Leicester Place from Charing Cross Road. You may also apply for special dispensation to drive up Leicester Place from Leicester Square and stop outside the door of the theatre at any time. Access can be applied for by filling the form below; 48 hours’ notice is required. https:/ / payments.westminster.gov.uk/WebFormsLive/Highways_and_parking/ StreetAccess/ All of these are for loading and unloading only; do not leave your vehicle unattended at any time.

After 12:00 all roads around the theatre become pedestrianized. We do not have parking at the theatre; the nearest NCP (limited headroom) is Chinatown, Newport Place. There is a 20% discount available at Chinatown car park when you book on-line with promotion code China. Visit www.q-park.co.uk and search Chinatown.

Load in is via a narrow staircase with several turns. It is possible to bring an 8’ by 4’ stage flat down these stairs. It is advisable to arrange a visit to the space before finalising any set design to be brought in.

If you would like any advice about access to the theatre, please email Gareth Potts. [email protected].

TECH TIME:

You may book up to two hours for technical rehearsals prior to your first performance free of charge. Additional time may be made available but is chargeable at £30/hr +VAT. If yours is the first performance of the evening (usually 7pm) your two hours will normally be immediately prior to your performance, i.e. from 5pm to 7pm. Later shows will be scheduled to tech earlier in the day, e.g. if your performance is at 9:30pm you may be able to rehearse from 3pm to 5pm.

A technician familiar with the venue can be booked for £15/hr +VAT for a minimum of 4 hours.

Minimum calls cannot be split. i.e. if a technician is called for a rehearsal in the afternoon and a show later, they must be paid for two calls or the number of hours between the start of their first call and the end of their second, whichever is less. This is because all of our technicians are employed on a freelance basis.

Any technical assistance you need from the venue must be pre-arranged. There will not necessarily be trained staff on site.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

3

Lounge Tech Spec., Revised 9/6/2016

AUDITORIUM:

The stage area is flat on the floor. The floor covering is black carpet over concrete. The ceiling height varies between 3.0m and 2.75m in most of the room. There are other low clearance points marked on the plan below. The walls of the Lounge are covered with a hard substance called Masonite which is very difficult to drill or fix into. Please bear in mind the dimensions and construction of the Lounge when designing your set or performance.

Please take all necessary precautions to ensure your performance will not cause damage to the fabric of the venue. Any food waste or fluid spills left after a performance must be cleaned up before you vacate the premises. Please keep the use of gaffer tape on the painted walls to a minimum. You may not perform with the rear ‘lift shaft’ doors open as sound carries through to the church, offices and accommodation above.

Any damage to the theatre or equipment may be recharged.

The available playing area will depend upon the arrangement and number of seats specified on your booking form. Normal playing area between the pillars is 2.3m x 2.3m. Up to 65 seats are provided with the venue, a combination of wooden chairs and chrome bar stools. There are also 4 small round tables (about 20” diameter), which are available with or without black table cloths.

STAGE POWER: 1x twin 13A socket either side of stage 1x twin 13A socket at height stage left 1x single 13A socket on each pillar in the centre of the room

DRESSING ROOMS:

There are two dressing rooms attached to the space which can comfortably accommodate up to ten performers in total. There are hot and cold running water, counters, mirrors and electrical outlets in both dressing rooms. Dressing room ‘A’ may be accessed either from the space or from the stairwell leading to the theatre, which is the audience access route. Dressing room ‘B’ may only be accessed via the performance space.

Like all the spaces in the theatre, dressing rooms are shared between several productions. Please keep the theatre tidy and consider other productions’ needs. Set, costume and other equipment is left at your own risk & may not be left at the theatre outside the duration of your run. The theatre is not responsible for these, or for any valuables left in the dressing rooms.

Decisions about where items may be left are at the House Manager’s discretion. Any items left at the theatre must be clearly labelled with the name of your production and the contact details of a responsible person who will be at every performance. There are lockers in the dressing rooms which may be used for storing small props during your run. Locker keys are available from the House Manager in exchange for a cash deposit of £25. This deposit will be reimbursed upon return of the key if the locker is clear, clean and undamaged.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

4

Lounge Tech Spec., Revised 9/6/2016 FILMING:

It is prohibited to film, video, photograph or record any part of the performance without prior agreement. A facility fee will be charged where agreement is provided by the theatre for recordings that will be used in a commercial capacity including but not limited to DVD, CD, broadcast and streaming. Theatre accreditation must be agreed in advance.

If the recording is for private use, there may not be a charge but it must still be agreed in advance. Capacity may need to be reduced to accommodate cameras and operators; please advise box office immediately if seats need to be taken off sale (I estimate 3 seats per camera). Placement of filming equipment and personnel must not be allowed to affect fire escape or access routes. The front of house manager or supervisor on duty will need to be certain that routes are not blocked before opening the house and their decision is final.

LIGHTING:

The fixed lighting rig (which cannot be altered) consists of 21 LED fixtures and one conventional fixture controlled by a computerised lighting desk. In the default program (lounge3), these lanterns are grouped such that the standard playing area can be divided into sections and can be lit in any colour by combining red, green, blue and white elements. Conventional fixtures may be used in conjunction with the in house dimmers. A smoke machine is available for use in the Lounge. It is shared with the large auditorium so if you wish to use it, the smoke machine must be booked in advance. There is a small additional charge for the use of the smoke machine.

The maximum total load on the three Alphapack dimmers must not exceed 3000W. Additional lighting elements may only be rigged by prior arrangement.

LIGHTING CONTROL: Zero88 Jester ML24 lighting console 3 x Zero88 Alphapack 3-channel dimmer packs 6 way soca multi from dimmer patch bay to lighting grid 1 x Showtec 4 way DMX distribution booster

LIGHTING STOCK: 2x Chauvet Colorado 1 Quad Tour LED fixtures (personality Arc2+S) 14x Chauvet Colordash Accent LED fixtures (personality Arc2) 2x Chauvet Colorrail IRC LED batten fixtures (26ch mode) All in fixed positions, as per plan in Appendix 4 1x Chauvet Ovation E-190WW LED Profile fixture 4x Selecon PL1 LED Fresnel fixtures 24 lamp festoon of 40W filament lamps Used as houselights 3x additional Chauvet Colordash Accent LED fixtures (personality Arc2) 5x Birdie par16 fixtures May be rigged and focused by incoming companies as specials 2x par30 fixtures on a first-come first-served basis 1x strobe light (to be used on an independent feed, not dimmed)

ATMOSPHERIC EFFECTS: 1x QTX Light QTFX-V1 Vertical Fog Machine There is a charge of £5 per performance for the use of the smoke machine.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

5

Lounge Tech Spec., Revised 9/6/2016 SOUND:

Venue hire includes use of four corded microphones, two DI boxes, electric piano and twin CD player all controlled through an analogue mixing desk. Two wireless microphones are available for a small additional charge. It is also possible to connect an MP3 player or computer sound source to the system via a 3mm stereo jack connection. A MacMini computer is available for this purpose for a small additional charge. A selection of music CDs are available for use as play-in music.

If you wish to use your own radio microphones the following frequencies may not be used at any time: 840.125MHz & 845.500MHz. Other frequencies may also be off limits if used by shows in the main house. Please check before you arrive. Additional sound equipment may only be brought into the venue by prior arrangement. Please put any CDs or sound equipment you use back in the appropriate place after your show.

SYSTEM: 1x Yamaha MG206C-USB Mixing desk – 12 mono, 4 stereo input channels, stereo and control room out & 4 aux sends 2x Mackie SRM-350 active speakers (may not be re-focused) 1x Numark dual CD player 1x phono to mini jack cable (for Ipod/laptop) 1x 4 in & 4 out stage box to desk (back of stage left pillar) 1x Alesis Microverb 4 reverb box 1x Behringer Ultragraph FBQ-Pro 3102 graphic equalizer

MICROPHONES: 4x Shure SM58

DI BOXES: 2x DI

MIC STANDS: 8x tall stands: a mixture of bases, straight and boom.

INSTRUMENT: 1x Classenti cdp3 electric upright piano

RADIO MICS: There is an additional charge of £5 each per performance for the use of the radio microphones. 2x Shure PG58 handheld cardioid radio microphones

COMPUTER: There is an additional charge of £30 per performance for the use of the computer. 1x Apple MacMini computer running Q-Lab show control software with a full video license. OS X version 10.8.5 Qlab version 3.0.8

VARIOUS AUDIO AND POWER CABLES.

ATMOSPHERIC EFFECTS: 1x QTX Light QTFX-V1 Vertical Fog Machine There is an additional charge of £5 per performance for the use of the smoke machine. AV:

There is a video projector permanently rigged in the centre of the venue, focused on the area upstage, this can be fed from a VGA source. There is a projection screen available which may be hung against the back wall.

Please make sure you are able to connect your source to the projector. If you wish to run video from an Apple Mac computer, you must provide a video output adaptor.

AV EQUIPMENT: 1x Epson EB-S6 video projector For the time being, there is no charge for using the projector. 1x Quick screen for front projection 2.5m x1.5m VGA cable from projector to operating position VGA cable from projector to stage

ATMOSPHERIC EFFECTS: 1x QTX Light QTFX-V1 Vertical Fog Machine There is an additional charge of £5 per performance for the use of the smoke machine.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

6

Lounge Tech Spec., Revised 9/6/2016 Appendix 1:

Lounge3 LIGHTING DESK SHOW FILE:

The standard show file loaded into the Jester lighting desk when you arrive is called Lounge3. You may alter the patch and cues for your own performance but do not save over show file Lounge3.

The standard rig is patched into the desk in show file Lounge3 and the following states are pre- programmed into submasters 13 thru 24.:

Submaster 13: full stage warm white wash

Submaster 14: centre stage cover (between the pillars)

Submaster 15: SR cover

Submaster 16: SL cover

Submaster 17: Red cover

Submaster 18: Green Cover

Submaster 19: Blue Cover

Submaster 20: projection state (takes light off the upstage area)

Submaster 21: centre stage spot

Submaster 22: dramatic backlight (cold white backlight between the pillars)

Submaster 23: preset and houselights (a red and blue stage preset state and the festoon bulbs)

Submaster 24: ‘rock’ chase (flashes the white lights at a variable speed)

To use the submasters, make sure the desk is in show Lounge3, in Run Mode, and that fader bank B is assigned to Submasters 13-24.

Submasters can be combined to make other states. Individual channels may be accessed in run mode using fader bank A.

(note to lighting designers: the Lounge3.jsf show file pairs fixtures and treats their attributes as individual dimmer channels in order to provide submasters which act in a highest takes precedence (HTP) manner. If you require control of individual attributes of fixtures or wish to build palettes, you should base your show file on the show file LEDPATCH.jsf. See appendix 7)

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

7

Lounge Tech Spec., Revised 9/6/2016 Appendix 1(a):

PATCH REFERENCE SHEET FOR SHOW Lounge3:

CHANNEL FADERS: FIXTURE S:

Channel: 1 2 3 4 5 6 7 8 9 10 11 12 PAGE 1:

1 2 3 4 5 6 7 8 9 290 200+210 205+215

Address: Fixture: 1 2 3 4 5

Address: 070+075 071+076 072+077 073+078 055 Attribute Downstage Downstage Downstage Downstage SL Face, /description: cover, Red cover, Green cover, Blue cover, White Red

Attribute Par 30 Par 30 Festoon houselights Centre Spot, Open White LED pars, intensity * LED pars, Strobe * Fixture: 6 7 8 9 10 /description: Address: 056 057 058 050 051 Attribute SL Face, SL Face, SL Face, SL Face, SL Face, /description: Green Blue White Red Green

PAGE 2

Fixture: 11 12 13 14 15 Address: 052 053 060 061 062 Attribute SL Face, SL Face, SR Face, SR Face, SR Face, /description: Blue White Red Green Blue

Channel: 13 14 15 16 17 18 19 20 21 22 23 24 Fixture: 16 17 18 19 20

Address: 211 212 213 214 201 202 203 204 040 030 041 031 042 032 043 033 Address: 063 065 066 067 068 Attribute SR Face, SR Face, SR Face, SR Face, SR Face, +045 +035 +046 +036 +047 +037 +048 +038 /description: White Red Green Blue White

LED par, SL, LED par, SL, LED par, SL, LED par, SL, LED par, SR, LED par, SR, LED par, SR, LED par, SR, Upstage cover, Upstage cover, Upstage cover, Upstage PAGE 3: Attribute /description: Fixture: 21 22 23 24 25 Address: 015+020 016+021 017+022 018+023 010 + 025

cover, Attribute CS Backlight, CS Backlight, CS Backlight, CS Backlight, Wings Backlight, /description: Red Green Blue White Red

Red Green Blue White Red Green Blue White

Red Green Blue White Fixture: 26 27 28 29 30

*

*

*

*

Address: 011+026 012+027 013+028 220+250

*

*

*

*

Attribute Wings Backlight, Wings Backlight, Wings Backlight, Chauvet /description: Green Blue White Colorrails

* Channels 12 to 20 require channel 11 to be at full or they will not respond

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

8

Lounge Tech Spec., Revised 9/6/2016

Appendix 2:

HOW TO LOAD A PREVIOUSLY SAVED SHOW FROM A USB STICK ONTO THE ZERO88 JESTER ML24 LIGHTING DESK:

Hold down SHIFT & MODE until the ● SETUP mode light is lit.

You are in the SETUP menu.

  Use the arrow keys to select . Hit ENTER .

 Arrow down to select . Hit ENTER .

  Arrow to the show you want (e.g. Lounge3). will flash. Hit ENTER .

The desk will say: SUCCESS. will flash. Hit ENTER .

 Arrow across to . Hit ENTER .

You are back in the SETUP menu.

Hold down SHIFT & MODE until the light moves from ● SETUP to ● RUN.

CHANGING MODES

If the desk is in ● PRESET mode, hold down MODE to change to ● PROGRAM mode.

If the desk is in ● PROGRAM mode, tap MODE to change to ● RUN mode.

Please return the desk to show Lounge3 in ● RUN mode at the end of each performance. Thank you.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

9

Lounge Tech Spec., Revised 9/6/2016

Appendix 3:

PHOTOS OF THE VENUE:

Various set pieces have been built for in house productions, including: a D-shaped raised stage designed to fit between the onstage pillars; backcloths and various doorways and arches. Some of these are stored at the venue but may be used by incoming companies by prior arrangement ONLY. There will be a charge for use of set as a theatre technician is required to help move the set pieces and you must factor in moving the pieces into your turnaround time when playing on top of other shows.

All technical enquiries about the Lounge should be directed to David Meunier-Palmer. [email protected] 020 7534 1746

10

7m Twin 13A socket Twin 13A socket Lounge Tech Spec., Revised 9/6/2016 220 250

Twin 13A socket Appendix 4:

15 20 2.3m LIGHTING RIG PLAN:

Dressing

Overhead Tech Room ‘A’ at height2.55m Store 25

 10

35 Lighting grid height 2.64m 40

45 30

The Lounge @ Leicester Square Theatre 6 Leicester Place, London WC2H 7BX

Ground plan prepared 6/5/16 by David Meunier-Palmer Entrance 3.7m [email protected] 65

55 50 Diagram shows one possible 1 60 15 Lift Shaft arrangement of 65 seats in venue. 2 14 Scale = approx 1:25 at A3 3 13 Please check measurements in person. 4 12 5

6 7 8 9 10 11 31

1

- 3

30 200 210 32 16 300 320 340 360

29 Dimmer

4 -

Ovation Profile 6

17 Cupboard 290 28 Single 13A socket 18

27 7 - 19 20 21 22 75 9 33 70 23 24 25 26 46 Single 13A socket Single 13A socket 45 34 44 Projector 35 43 Key: 36 42 37 38 39 40 41 85 Colorado 1 Quad Tour fixture 80 DMX Address 54 Colordash Accent fixture 53

Zero88 Alphapack dimmer Bar 47 48 49 50 51 52

65 Colorrail IRC batten fixture 64

Dressing Room ‘B’ Selecon PL1 LED Fresnel fixture 55 56 57 58 59 60 61 62 63 

Lounge Tech Spec., Revised 9/6/2016 Appendix 6:

STANDARD LIGHTING PATCH:

DMX Address: Fixture: Attribute Position in rig: Focus: Notes:

001 Dimmer 002 Par 30 Dimmer CSR 003 Par 30 Dimmer CSL 004 Dimmer 005 Dimmer 006 Festoon Houselights Dimmer 007 Dimmer 008 Dimmer 009 Dimmer 010 Chauvet Colordash Accent (personality Arc2) Red USR stage right backlight 011 “ Green “ “ 012 “ Blue “ “ 013 “ White “ “ 014 015 Chauvet Colordash Accent (personality Arc2) Red USCR centre stage backlight 016 “ Green “ “ 017 “ Blue “ “ 018 “ White “ “ 019 020 Chauvet Colordash Accent (personality Arc2) Red USCL centre stage backlight 021 “ Green “ “ 022 “ Blue “ “ 023 “ White “ “ 024 025 Chauvet Colordash Accent (personality Arc2) Red USL stage left backlight 026 “ Green “ “ 027 “ Blue “ “ 028 “ White “ “ 029 030 Chauvet Colordash Accent (personality Arc2) Red mid SR up stage centre stage face light 031 “ Green “ “ 032 “ Blue “ “ 033 “ White “ “ 034 035 Chauvet Colordash Accent (personality Arc2) Red mid SR up stage centre stage face light 036 “ Green “ “ 037 “ Blue “ “ 038 “ White “ “ 039

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

12

Lounge Tech Spec., Revised 9/6/2016

DMX Address: Fixture: Attribute Position in rig: Focus: Notes:

040 Chauvet Colordash Accent (personality Arc2) Red mid SL up stage centre stage face light 041 “ Green “ “ 042 “ Blue “ “ 043 “ White “ “ 044 045 Chauvet Colordash Accent (personality Arc2) Red mid SL up stage centre stage face light 046 “ Green “ “ 047 “ Blue “ “ 048 “ White “ “ 049 050 Chauvet Colordash Accent (personality Arc2) Red SR doorway stage right face light 051 “ Green “ “ 052 “ Blue “ “ 053 “ White “ “ 054 055 Chauvet Colordash Accent (personality Arc2) Red mid SR stage right face light 056 “ Green “ “ 057 “ Blue “ “ 058 “ White “ “ 059 060 Chauvet Colordash Accent (personality Arc2) Red mid SL stage left face light 061 “ Green “ “ 062 “ Blue “ “ 063 “ White “ “ 064 065 Chauvet Colordash Accent (personality Arc2) Red SL doorway stage left face light 066 “ Green “ “ 067 “ Blue “ “ 068 “ White “ “ 069 070 Chauvet Colordash Accent (personality Arc2) Red DSR pillar down stage centre stage face light 071 “ Green “ “ 072 “ Blue “ “ 073 “ White “ “ 074 075 Chauvet Colordash Accent (personality Arc2) Red DSL pillar down stage centre stage face light 076 “ Green “ “ 077 “ Blue “ “ 078 “ White “ “ 079

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

13

Lounge Tech Spec., Revised 9/6/2016

DMX Address: Fixture: Attribute Position in rig: Focus: Notes:

080 Chauvet Colordash Accent (personality Arc2) Red DSR pillar down stage centre stage face light 081 “ Green “ “ 082 “ Blue “ “ 083 “ White “ “ 084 085 Chauvet Colordash Accent (personality Arc2) Red DSL pillar down stage centre stage face light 086 “ Green “ “ 087 “ Blue “ “ 088 “ White “ “

200 Chauvet Colorado 1 Quad Tour (pers. Arc2+S) Dimmer Mid SR centre stage face light 201 Red “ “ 202 Green “ “ 203 Blue “ “ 204 White “ “ 205 Strobe “ “

210 Chauvet Colorado 1 Quad Tour (pers. Arc2+S) Dimmer Mid SL centre stage face light 211 Red “ “ 212 Green “ “ 213 Blue “ “ 214 White “ “ 215 Strobe “ “

220 Chauvet Colorrail IRC (pers. 26ch) Dimmer USCL Midstage centre backlight 221 Red 1 “ “ 222 Green 1 “ “ 223 Blue 1 “ “ 224 Red 2 “ “ 225 Green 2 “ “ 226 Blue 2 “ “ 227 Red 3 “ “ 228 Green 3 “ “ 229 Blue 3 “ “ 230 Red 4 “ “ 231 Green 4 “ “ 232 Blue 4 “ “ 233 Red 5 “ “ 234 Green 5 “ “ 235 Blue 5 “ “ 236 Red 6 “ “ 237 Green 6 “ “ 238 Blue 6 “ “

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

14

Lounge Tech Spec., Revised 9/6/2016

DMX Address: Fixture: Attribute Position in rig: Focus: Notes:

239 Red 7 “ “ 240 Green 7 “ “ 241 Blue 7 “ “ 242 Red 8 “ “ 243 Green 8 “ “ 244 Blue 8 “ “ 245 Strobe “ “

250 Chauvet Colorrail IRC (pers. 26ch) Dimmer USCR Midstage centre backlight 251 Red 1 “ “ 252 Green 1 “ “ 253 Blue 1 “ “ 254 Red 2 “ “ 255 Green 2 “ “ 256 Blue 2 “ “ 257 Red 3 “ “ 258 Green 3 “ “ 259 Blue 3 “ “ 260 Red 4 “ “ 261 Green 4 “ “ 262 Blue 4 “ “ 263 Red 5 “ “ 264 Green 5 “ “ 265 Blue 5 “ “ 266 Red 6 “ “ 267 Green 6 “ “ 268 Blue 6 “ “ 269 Red 7 “ “ 270 Green 7 “ “ 271 Blue 7 “ “ 272 Red 8 “ “ 273 Green 8 “ “ 274 Blue 8 “ “ 275 Strobe “ “

290 Chauvet Ovation E-190WW LED Profile Dimmer C/S centre stage hard spotlight

300 Selecon PL1 LED Fresnel (pers. 8bit) Intensity SR SR top light 301 Red “ “ 302 Green “ “ 303 Blue “ “ 304 White “ “ 305 Preset “ “

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

15

Lounge Tech Spec., Revised 9/6/2016

DMX Address: Fixture: Attribute Position in rig: Focus: Notes:

306 Not Used “ “ 307 Timing “ “

320 Selecon PL1 LED Fresnel (pers. 8bit) Intensity MSR MSR top light 321 Red “ “ 322 Green “ “ 323 Blue “ “ 324 White “ “ 325 Preset “ “ 326 Not Used “ “ 327 Timing “ “

340 Selecon PL1 LED Fresnel (pers. 8bit) Intensity MSL MSL top light 341 Red “ “ 342 Green “ “ 343 Blue “ “ 344 White “ “ 345 Preset “ “ 346 Not Used “ “ 347 Timing “ “

360 Selecon PL1 LED Fresnel (pers. 8bit) Intensity SL SL top light 361 Red “ “ 362 Green “ “ 363 Blue “ “ 364 White “ “ 365 Preset “ “ 366 Not Used “ “ 367 Timing “ “

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

16

Lounge Tech Spec., Revised 9/6/2016

Appendix 7:

PATCH REFERENCE SHEET FOR SHOW LEDPATCH:

CHANNEL FADERS: FIXTURE S:

Channel: 1 2 3 4 5 6 7 8 9 10 11 12 Fixture: 1 2 3 4 5

1 2 3 4 5 6 7 8 9 290

Address: Address: 110 115 010

Attribute Moveable Moveable SR Backlight /description:

Fixture: 6 7 8 9 10 Attribute Par 30 Par 30 Festoon Centre Spot, Open White Address: 50 300 320 55 070+080 /description: Attribute SR Face SR Toplight MSR Toplight SR Face Downstage

houselights /description: Face

PAGE 2

Fixture: 11 12 13 14 15 Address: 015 220 250 020 Attribute Chauvet Chauvet /description: Colorrail Colorrail

Fixture: 16 17 18 19 20

Channel: 13 14 15 16 17 18 19 20 21 22 23 24 Address: 200 030 035+040 045 210

Attribute CS Face Upstage face Far upstage Upstage face CS Face Address: /description: face

PAGE 3:

Attribute Fixture: 21 22 23 24 25 /description: Address: 025 120 125 Attribute SL Backlight Moveable Moveable /description:

Fixture: 26 27 28 29 30 Address: 075+085 60 300 320 65 Attribute Downstage SL Face MSL Toplight SL Toplight SL Face /description: Face

PAGE 1:

All technical enquiries about the Lounge should be directed to David Palmer. [email protected] 020 7534 1746

17