ISV Certification

Current Version 1.0 Approved By Jianwen Yin Approval Date 07/09/2012

Dell EqualLogic and Compellent Platform Certification Exit Form: Bloombase - Phase 1 (CEF)

This document contains information of a proprietary nature. ALL INFORMATION CONTAINED HEREIN SHALL BE KEPT IN CONFIDENCE. None of this information shall be divulged to persons other than employees authorized by the nature of their duties to receive such information, or individuals or organizations authorized by Dell research and development in accordance with existing policy regarding the release of company information

DELL Confidential Page 1 of 13

ISV Certification

Table of Contents

1. Document Revision History ...... 3 2. Introduction ...... 3 3. Certification Details ...... 4 Company Name: Bloombase Technologies Ltd ...... 4 4. Certification Test Scenarios ...... 4 5. Storage Platform Validation Confirmation ...... 5 Appendix ...... 6 A. Key Management ...... 6 1. Key Management -> Create Key Wrapper ...... 6 2. Generate and Submit ...... 6 3. Find Key Wrapper ...... 7 4. Assign Key to Virtual Storage ...... 8 5. Modify Virtual Storage Handler ...... 9 6. Add Encryption Key ...... 9 7. Find and Select the Encryption Key ...... 10 B. Access Control ...... 11 1. From Virtual Storage, select “Modify Virtual Storage Access Control” ...... 11 2. For FC-SAN, add allowed Host WWN ...... 11 3. For iSCSI, select CHAP users and Host/Subnet Access control ...... 12 C. Network Encrytpion ...... 13

DELL Confidential Page 2 of 13

ISV Certification

1. Document Revision History Revision Date Revised By Comments 0.1 05/11/2012 Dell Initial Draft For Discussion 0.2 06/10/2012 Bloombase Template details for Bloombase applications 0.3 07/06/2012 Bloombase Certification test results 1.0 07/09/2012 Dell Final Updates.

2. Introduction

The Dell Equallogic and Compellent Platform Certification Exit Form documents the evaluation of the Bloombase solution over Dell PowerEdge server and Equallogic and Compellent storage.

This Exit Form is meant to augment an existing Use Cases and Certification document (UCC) between Dell and Bloombase. The use cases documented in the UCC document are captured here in Pass/Fail test scenarios.

All test scenarios must pass for the ISV solution to be certified.

DELL Confidential Page 3 of 13

ISV Certification

3. Certification Details

Company Name: Bloombase Technologies Ltd

Usage Details: The Dell PowerEdge server R710 will be used for Bloombase Spitfire StoreSafe. Both Dell Equallogic and Compellent will be used as the storage device.

Testing Date: 07/05/2012

Dell Representatives: Jianwen Yin, Ryan King

Bloombase Representatives: Justy Wong, Derek Fung

Item Version Details Dell PowerEdge Server R710 Intel Xeon CPU X5550 (2.67GHz) 8 cores Dell Equallogic system system Bloombase Spitfire StoreSafe 3.5 Data at-rest encryption security server for NAS, SAN and object stores

4. Certification Test Scenarios Pass | # Test Scenario Required Result Notes Fail Solution is successfully Pass Refer to use case configured to use the Dell document Documentation: PowerEdge server, the Documents to cover the Equallogic and Compellent 1 deployment and use of the system; The solution shall Dell-Bloombase solution. include instructions on how to configure the Dell PowerEdge server and the storage device. 2 Interoperability Testing:  Discovery Pass All information is iSCSI data encryption  Connect Pass encrypted on the storage  Dell PowerEdge  Dump in raw device Pass device. R710  Dump out raw device Pass  Intel GbE NIC  Create filesystem Pass  Dell PowerConnect  Write to filesystem Pass Ethenet switch  Read from filesystem Pass  Dell Equallogic  Delete from filesystem Pass

DELL Confidential Page 4 of 13

ISV Certification

 Initialize disk Pass All information is FC-SAN data encryption  Dump in raw device Pass encrypted on the storage  Dell PowerEdge  Dump out raw device Pass device. R710  Create filesystem Pass  QLogic HBA  Write to filesystem Pass  Brocade SAN switch  Read from filesystem Pass  Dell Compellent  Delete from filesystem Pass 3 Performance Testing: Single LUN throughput tests  Over 80Mbps Pass 840Mbps  iSCSI  Over 100Mbps Pass 1.2Gbps  FC-SAN Multi-LUN throughput tests As limitation of the LUN and Link speed, test only  iSCSI  Over 800bps Pass with 2 LUNs and the results should be speed multiplied by #CPU

 FC-SAN  Over 1Gbps Pass cores. For iSCSI, 6.7Gbps for 8 cores For FC-SAN, 9.6Gbps 8 cores FINAL RESULTS Pass

5. Storage Platform Validation Confirmation

By completing this Exit Form Bloombase confirms that the Dell PowerEdge server, Equallogic and Compellent system will be validated by the typical QA process employed by Bloombase solution testing procedure and that issues found with the solution will be reported to Dell.

DELL Confidential Page 5 of 13

ISV Certification

Appendix Bloombase Spitfire StoreSafe Web Administration Console A. Key Management

1. Key Management -> Create Key Wrapper

2. Generate and Submit

DELL Confidential Page 6 of 13

ISV Certification

3. Find Key Wrapper

DELL Confidential Page 7 of 13

ISV Certification

4. Assign Key to Virtual Storage

DELL Confidential Page 8 of 13

ISV Certification

5. Modify Virtual Storage Handler

6. Add Encryption Key

DELL Confidential Page 9 of 13

ISV Certification

7. Find and Select the Encryption Key

DELL Confidential Page 10 of 13

ISV Certification

B. Access Control

1. From Virtual Storage, select “Modify Virtual Storage Access Control”

2. For FC-SAN, add allowed Host WWN

DELL Confidential Page 11 of 13

ISV Certification

3. For iSCSI, select CHAP users and Host/Subnet Access control

DELL Confidential Page 12 of 13

ISV Certification

C. Network Encrytpion Network packets between hosts and Bloombase Spitfire StoreSafe is protected by IPsec.

Sniffing the network sees no plain contents but only encrypted packets.

DELL Confidential Page 13 of 13