RISK BULLETIN ALLIANZ GLOBAL CORPORATE & SPECIALTY® PRINCIPLES OF INDUSTRIAL VENTILATION

ALLIANZ RISK CONSULTING

Image: Shutterstock

INTRODUCTION COMMON VENTILATION SYSTEMS Ventilation systems are an important, but often In industrial settings, the two basic types of ventilation overlooked, element of a plant safety program. A properly systems are Dilution Ventilation and Local Exhaust designed ventilation system will provide good air quality, Ventilation. environmental comfort, removal of hazardous DILUTION VENTILATION SYSTEM contaminants, and offer protection against fire and explosion. In fact, ventilation systems are the preferred Dilution Ventilation is designed to reduce the method of controlling exposure to chemical contaminants of pollutants in a work area by mixing and other environmental hazards in the workplace. outside air with the contaminated air. It also acts as a general ventilation system within the work area. Before This Risk Bulletin will describe the two most common types deciding if a Dilution Ventilation system is right for your of industrial ventilation systems in use today. The purpose, facility, consider these questions: design, operation, maintenance, and inspection requirements of both are also discussed. • Considering the amount of toxicity, dosage, and individual susceptibility, do the contaminants represent (Note that Heating, Ventilation, and a relatively low health or safety hazard? (HVAC) systems will not be covered here. See Allianz’s “Proper Building Ventilation Systems” Risk Bulletin for information on HVAC systems.) • Will chemicals be released over a wide area Criteria to consider when selecting and designing a Local and throughout the day? Exhaust Ventilation system (one or more may apply): • Are the , , or fumes used in your facility • Do the chemical contaminants represent a significantly unlikely to settle to the ground? high hazard? • Is your plant located in a moderate climate? (Hot or • Do the contaminants consist of larger particles that can cold outside air may affect the efficiency of a dilution settle over time? ventilation system.) • Do emission patterns vary over time? Tip: Some ignore these limiting factors, and others • Do emissions emanate from a single source? consider a Dilution Ventilation system to be the answer for all situations. This may be a mistake. If the contaminant • Do employees work in the immediate vicinity is toxic and present in significant volume, a Dilution of emission sources? Ventilation system will simply circulate the hazardous Examples of Local Exhaust Ventilation systems include contaminants around the work area. Additionally, spray paint booths, capture hoods for welding, and slot employees working nearby may be exposed to the ventilation systems on plating tanks, among others. hazardous material. Local Exhaust Ventilation systems offer better control Tip: In work areas where chemicals are present in high of contaminants, improved housekeeping, and lower , a Dilution Ventilation system is not always energy costs over a Dilution Ventilation system. the control method of choice. Under these circumstances, All exhaust ventilation systems, whether large or small, consider “substitution” or “elimination” of the chemical are relatively complex, requiring five basic elements: hazard as alternatives. • Hoods The effectiveness of a Dilution Ventilation system is usually measured by the number of room air changes that take • Fans place in an hour. Four to six air changes per-hour (ACH) • Ducts is typical for most ventilation systems. Depending on the industry and circumstance, an ACH factor of 20-25 may be • Air cleaners appropriate. The number of ACH may need to be adjusted, • Stacks depending on the nature of the contaminant and the existing environmental conditions. Larger units usually require multiple branches and capture hoods with sophisticated designs and intricate engineering Guidelines for an efficient Dilution Ventilation system: to achieve the desired control. • Place room exhausts (ceiling and wall fans) as close HOODS to the emission source as possible. Hoods capture contaminants from an emission source. • Use auxiliary fans for effective mixing of room air. The hoods are either “enclosure,” “receiving,” or “exterior.” • Place employees upwind of contaminant sources. • Enclosure hoods (such as a paint booth) completely • Add tempered (depending on climate conditions) enclose the point of contamination. make-up air in situations where it will be the most • Receiving hoods are located in the path of the effective. discharged contaminant (such as particles that come Note: “Make-up air” is clean, fresh air, free of contaminants off a grinding wheel). supplied to a work area in quantities equal to the volume • Exterior hoods capture contaminants from a point of air exhausted through the ventilation system. outside the hood (such as slot ventilation used on Tip: In areas of ambient temperature extremes, plating tanks or overhead canopy hoods). considerations should be made to temper (or blend) Tip: Make sure all hoods fit properly. An ill-fitting hood make-up air. This may involve significant energy costs, may not capture all the contaminant, and can possibly which is a good reason to consider an alternative exhaust clean air. ventilation system (see below). Tip: Take care not to place a worker between the LOCAL EXHAUST VENTILATION contamination source and the hood. This is particularly The primary purpose of a Local Exhaust Ventilation system important in instances where canopy hoods are used and is to capture and remove chemical contaminants at or when spraying is done inside the booth against the airflow. near the source. The components of a typical Local Both situations can increase the worker’s exposure to Exhaust Ventilation system usually includes a capture hazardous chemicals. hood, booth or other capture system, ductwork, an air cleaning or scrubbing system, a , and an exhaust system that vents outside the building.

2 FANS Typical air cleaners protect the components of the exhaust system and collect or trap solid , gases, and Fans move the air through the exhaust system and pull vapors. In some cases, this collected material can be taken contaminants through hoods, ductwork, and cleaners, to landfills or may be recycled. The regular maintenance ultimately exhausting to the outside. Fan design depends of air cleaners is essential to ensure the overall efficiency on the volume of air involved, desired velocity, type and of the ventilation system. concentration of contaminant, and the static pressure (or resistance) developed during the process. Tip: Take extreme caution when workers enter an air cleaner (especially a bag housing) to clean or make Tip: Many types of fans are available (from centrifugal repairs. The worker is at risk of exposure to high levels to axial). Carefully select the one that best suits your of contaminants and may suffer from insufficient oxygen. ventilation configuration and work environment. Follow applicable “Confined Space” rules. Tip: Improper fan selection or faulty installation can reduce air flow and cause short circuits, which could result STACKS in the contaminant being returned to the workplace The final component in a ventilation system is the exhaust and cause cross-contamination. stack. Stacks are usually mounted on the roof and direct exhaust into the outside air. Place stacks downwind from DUCTS any air intake vents, and calibrate the stack exhaust Ducts are passageways for the contaminants as they move velocity at 1.4 times the average wind velocity, or other from a hood, through the air cleaner or contaminant recommended value. collector, and to an exhaust outlet. Ducts are made with Tip: Place carefully sized stacks downwind from, different types of material, usually sheet metal, but plastic, and higher than, air intake vents to avoid re-entrapment fiberglass, and even concrete are becoming more of “bad air.” common. Design and arrange ductwork to minimize frictional loss (diminished airflow) and reduce the possibility of solid particles settling in the system. FIRE PROTECTION Tip: Too many side branches, elbows, and flex ducts tend Fire in exhaust ducts, kitchen hoods, or bag housings can to increase static pressure, which reduces fan present many problems. effectiveness. • Fire can be difficult to detect and extinguish Tip: “Blast gates” are often used with multiple branch • Ductwork can spread a fire quickly to other parts ventilation systems. They close off branches not in use, of the building thereby making the overall system more effective. Require that anyone adjusting blast gates receive proper training. Small particles such as wood or grain dust are highly combustible and can ignite from sparks generated Tip: Ducts that exhaust dust can clog easily. For maximum from metal contaminants (nails and staples) that strike efficiency, check and clean ports often. the inside of the ducts. Other potential fire hazards come Tip: Although the source of the contamination may have from buildup inside exhaust ducts and hoods in been shut down, keep the system operating to allow time commercial kitchens, exhaust ducts from paint booths, and for the contaminant to exit through the ventilation system dust collected inside bag house assemblies. Some control completely. measures include: Tip: Separate systems may be necessary to exhaust • Spark detection systems inside exhaust ducts incompatible materials. A good example is printing monitored by an alarm panel. operations where and oxidizers are both used. • Fire suppression systems inside ductwork and bag (Ozone from the plate developer is the oxidizer that could houses. mix with flammable vapors from the roller blanket wash). • Explosion venting built inside ducts. AIR CLEANERS • Regular inspections for accumulation of dust inside Air cleaners range from bag houses, cyclones, scrubbing ductwork; examination of exterior surfaces. towers, or thermal oxidizers, and are selected based on the nature of the contaminant. Governing agencies may • Sprinkler heads inside ducts and paint booths. mandate a specific type of air cleaner, so check local • Regular cleaning and treatment of kitchen exhaust codes and regulations. systems. • Regular servicing of kitchen fire suppression systems.

3 MAINTENANCE Tip: Leave the task of ventilation measurement to engineers or technicians familiar with system requirements. All ventilation systems require regular inspection and However, a quick check of flow rates can be performed by maintenance to assure effective and continual operation. maintenance staff using a variety of instruments and Local Exhaust Ventilation systems are especially prone to methods, including velometers, inclined manometers (as wear and tear, and any damage can greatly affect the seen on the sides of spray paint booths), and smoke tube performance of the system. Develop a regularly scheduled tests. inspection and maintenance program to help the staff Tip: Never force inappropriate material (such as large keep the system operating properly. wood chips or trash) through any ventilation system. An effective maintenance and inspection program should Ventilation systems are NOT designed to be trash include: receptacles. • Measuring static pressures in the system. SUMMARY • Checking the airflow capture velocity at the hoods. The most effective way to protect workers from airborne • Checking the fan performance against original design contaminants is through a ventilation system. It can and specifications. provide a comfortable environment, and reduce or • Checking the operation of the air cleaner. eliminate the need for personal protective equipment such as respirators. Properly designed systems can also help • Inspecting hoods, ducts, elbows, and connectors reduce fire and explosion hazards by removing flammable for damage or leaks. solvents or combustible dust from the work environment. • Re-balancing the system whenever additions It is important that management and employees know or changes have been made. and understand the design and proper operation of a • Tempering any recycled air (particularly relevant ventilation system, its limitations, and maintenance and in colder climates). inspection requirements. This will assure efficient and effective operation of the system. Your maintenance program should examine the system with these questions in mind: FOR FURTHER ASSISTANCE: • Has the ventilation system been modified in any way since originally installed? Visit these Government Web sites: • Have additional branch lines been added? • Occupational Safety and Health Administration: www.osha.gov • Has the nature of the contaminant changed since the original installation? • National Institute for Occupational Safety and Health: www.cdc.gov/niosh/ • Have OSHA or industry standards become more restrictive for the contaminants being removed? A “Yes” answer may require a reevaluation of your system to make sure it performs according to specifications and current conditions.

Design: Graphic Design Centre

Disclaimer & Copyright © 2020 Allianz Global Corporate & Specialty SE. All rights reserved.

The material contained in this publication is designed to provide general information only. While every effort has been made to ensure that the information provided is accurate, this information is provided without any representation or guarantee or warranty of any kind about its accuracy and completeness and neither Allianz Global Corporate & Specialty SE, Allianz Risk Consulting GmbH, Allianz Risk Consulting LLC, nor any other company of Allianz Group can be held responsible for any errors or omissions. This publication has been made on the sole initiative of Allianz Global Corporate & Specialty SE.

All descriptions of services remain subject to the terms and conditions of the service contract, if any. Any risk management duties as laid down in the risk service and/or consulting contracts and/or insurance contracts, if any, cannot be delegated neither by this document, no in any other type or form.

Some of the information contained herein may be time sensitive. Thus, you should consult the most recent referenced material. Some of the information given in this publication may not apply to your individual circumstances. Information relating to risk services is intended as a general description of certain types of risk and services to qualified customers. Allianz Global Corporate & Specialty SE does not assume any liability of any kind whatsoever, resulting from the use, or reliance upon any information, material or procedure contained in this publication. 4