A.Section Includes:Durable,Decorativewallpanelswith Smooth Or Textured Finishes.Mounting

A.Section Includes:Durable,Decorativewallpanelswith Smooth Or Textured Finishes.Mounting

Section097700 |SpecialWallSurfacing

PART1:GENERAL

1.01Summary

A.Section Includes:Durable,decorativewallpanelswith smooth or textured finishes.Mounting hardware,adhesives,accessoriesand trims.

B.RelatedSections:

1.Division06Section:RoughandFinishCarpentry.

2.Division09Section:GypsumBoardAssemblies.

1.02References

SpecifierNote:Articlebelowmaybeomittedwhenspecifyingmanufacturer’sproprietaryproductsandrecommendedinstallation.RetainReferencesArticlewhenspecifyingproductsandinstallationbyanindustryreferencestandard.Ifretained,liststandard(s)referencedinthissection.Indicateissuingauthorityname,acronym,standarddesignationandtitle.Establishpolicyforindicatingeditiondateofstandardreferenced.ConditionsoftheContractorDivision01ReferencesSectionmayestablishtheeditiondate of standards.This article doesnotrequirecompliancewithstandard,butismerelyalisting of referencesused.Articlebelowshouldlistonlythoseindustrystandards referencedinthissection.

A.General:Standardslistedbyreference,including revisionsbyissuing authority, formapart ofthisspecificationsectiontotheextentindicated.Standardslistedareidentifiedbyissuingauthority,authorityabbreviation,designationnumber,titleorotherdesignationestablishedbyissuingauthority.Standardssubsequentlyreferencedhereinarereferredtobyissuingauthorityabbreviationandstandarddesignation.

B.ASTMInternational:

1.ASTME84StandardTestMethodforSurfaceBurningCharacteristicsofBuildingMaterials.

2.ASTMD256StandardTestMethodsforDeterminingtheIzodPendulumImpactResistanceofPlastics.

3.ASTMD638StandardTestMethodforTensileProperties ofPlastics.

4.ASTMD790StandardTestMethodsforFlexuralPropertiesofUnreinforcedandReinforcedPlasticsandElectricalInsulatingMaterials.

5.ASTMD2583StandardTestMethodforIndentationHardness ofRigidPlasticsbyMeans ofaBarcolImpressor.

1.03SystemDescription

A.PerformanceRequirements:Providedurable,decorativewallpanelswhichhavebeenmanufacturedandinstalledtomaintainperformancecriteriastatedbymanufacturerwithoutdefects,damageorfailure.

1.04Submittals

SpecifierNote:ArticlebelowincludessubmittalofrelevantdatatobefurnishedbyContractorbefore,duringorafterconstruction.CoordinatethisarticlewithArchitect’sandContractor’sdutiesandresponsibilitiesinConditions oftheContractandDivision01SubmittalProceduresSection.

A.General:Submit listedsubmittals inaccordancewithConditions of theContract andDivision01300Submittal ProceduresSection.

B.Product Data: Submitmanufacturer’sproductdata, storage,handlingandpreparationrequirementsandinstallationinstructions.

C.Shop Drawings:Submit shopdrawings showinglayout,profiles andproduct components, includinganchorage,accessories,finishcolors, patterns andtextures.Indicatelocationanddimensionofjointsandfastenerattachment.

D.Samples: Submit selectionandverificationsamples forfinishes, colorsandtextures.Submit 2samplesofeachtypeof panel,trimandfastener.

General:Firmexperienced in successfulproductionofwall system similarto thatindicatedfortheProject.QualityAssurance/Control Submittals: Submit thefollowing:

1.Test Reports:Certifiedtest reports showingcompliancewithspecifiedperformancecharacteristicsandphysical properties.

2.Certificates:

a.Submitmanufacturer’s certificatethatproductsmeet orexceedspecifiedrequirements.

b.Submitcertificateofinstaller’s qualifications.

SpecifierNote:Formoreinformationoninstallationrecommendations,visitmanufacturer’swebsiteat

3.Manufacturer’sInstructions:Manufacturer’sinstallation instructions.

F.CloseoutSubmittals:Submitthefollowing:

1.OperationsandMaintenanceData:Operation and maintenance data forinstalledproductsinaccordancewithDivision 01 CloseoutSubmittals(Maintenance Data and OperationData) Section.Include methodsfor maintaining installedproductsand precautionsagainstcleaning materialsandmethodsdetrimentalto finishesand performance.

2.Warrantydocumentsspecifiedherein.

1.05QualityAssurance

SpecifierNote:Articlebelowshouldincludeprerequisites,standards,limitations andcriteriathatestablishanoveralllevelofqualityforproducts andworkmanshipforthissection.CoordinatearticlebelowwithDivision01QualityAssuranceSection.

A.Installer Qualifications:Installershallhavea minimumof5 yearsexperiencewith compositewallpanelworksimilar in scopeandsize to thisproject.

SpecifierNote:Paragraphbelowshouldlistobligationsforcompliancewithspecificcoderequirementsparticulartothissection.GeneralstatementstocomplywithaparticularcodearetypicallyaddressedinConditions of theContractandDivision01RegulatoryRequirementsSection.Repetitivestatementsshouldbeavoided.

B.RegulatoryRequirementsandApprovals:[Specifyapplicable requirementsofregulatoryagencies.].

SpecifierNote:Retainparagraphbelowifmock-upisrequired.

C.Mock-Ups:[Specifyrequirementsfor mock-up.].

1.Subjectto acceptance byowner,mock-up may be retained aspartoffinishwork.

2.Ifmock-up isnotretained,removeandproperly disposeofmock-up.

SpecifierNote:Retainparagraphbelowifpreinstallationmeetingisrequired.

D.PreinstallationMeetings:[Specifyrequirementsfor meeting].

1.06Delivery,Storage &Handling

SpecifierNote:Articlebelowshouldincludespecialanduniquerequirements.CoordinatearticlebelowwithDivision01ProductRequirementsSection.

A.General:Complywith Division01ProductRequirementsSection.

B.Lead Time:Complywith manufacturer’sordering instructionsand lead time requirementsto avoid construction delays.

C.Delivery:Deliver materialsin manufacturer’soriginal,unopened,undamaged containerswith identification labelsintact.

D.Storageand Protection:Store materialsprotected fromexposure toharmfulenvironmentalconditionsandattemperature andhumidity conditionsrecommended bythe manufacturer.

1.Storepanelsindoors.

2.Laypanelsflat.Donotstandpanelsonedge.

3.Protectpanelsfrommoisture.

4.Do notstorepanelsin contactwiththe floororagainstan outsidewall.

5.Do notremove protective filmfrompanelsurface untilafterinstallation(ifapplicable).

6.Maintainoptimumstorage conditionsof60-75 degreesF(16-24 degreesC) at35- 55%relativehumidity.Avoidextremesin temperatureand humidity.

E.Handling:Remove foreign matterfromface ofpanelbyusing a softbristle brush,avoidingabrasiveaction.

1.07Project/SiteConditions

SpecifierNote:Inarticlebelow,statephysical orenvironmentallimitationsorcriteriaforinstallationsuch as weather,temperature,humidity,ventilationorilluminationrequiredforproperinstallationorapplication.

A.EnvironmentalRequirements:

1.Installation shallnotbegin untilbuilding isenclosed,permanentheatingand cooling equipmentisinoperation andresidualmoisture fromplaster,concreteor terrazzoworkhasdissipated.

2.Installpanelsbetween 60 degreesF- 75degreesF(15-24degreesC)and relative humiditybelow55%,ideally atthe same conditionsastheroom’snormaloperatingtemperaturesafterbuilding isoccupied.

3.Provideventilation todisperse fumesduringapplicationofadhesive asrecommendedbyadhesivemanufacturer.

4.Donotinstallwallsystemuntilnormallighting conditionsexist.Normallighting conditionsaredescribed asthose in placewhenthe projectisfinished.

B.Field Measurements:Verifyactualmeasurements/openingsbyfieldmeasurementsbefore fabrication;show recordedmeasurementson shopdrawings.Coordinate field measurementsand fabrication schedulewith construction progresstoavoidconstructiondelays.

1.Wall,ceilings,floorsandopeningsmustbe level,plumb,straight,in-line and square

1.08Warranty

SpecifierNote:CoordinatearticlebelowwithConditions oftheContractandwithDivision01CloseoutSubmittals (Warranty)Section.

A.ProjectWarranty:Refer to ConditionsoftheContractforprojectwarrantyprovisions.

B.Manufacturer’sWarranty:Submit,for Owner’sacceptance,manufacturer’sstandardwarrantydocumentexecuted byauthorized company official.Manufacturer’swarrantyisinadditionto,and nota limitationof,other rightsOwner mayhaveunder ContractDocuments.

SpecifierNote:Coordinateparagraphbelowwithmanufacturer’swarrantyrequirements.

C.WarrantyPeriod:[Specify term.]yearscommencingonDate ofSubstantialCompletion.

1.Warrantyextendsto productsassembled /installed andusedin the mannerintended and doesnotcoverdamageor failure causedby:misuse,abuse or accidents,exposureto extreme temperature,improperinstallation,improper maintenance andexposure towaterorexcessive humidityorexcessivemoisture.

1.09Maintenance

SpecifierNote:Retainarticlebelowforproprietarymethodspecification.Addproductattributes;performancecharacteristics,materialstandardsanddescriptions asapplicable.Use ofsuchphrasesas“or equal” or“orapprovedequal” or similarphrasesmaycause ambiguityin specifications.Suchphrasesrequireverification(procedural,legalandregulatory)andassignmentofresponsibilityfordetermining“orequal”products

A.ExtraMaterials:Provide [Arecommendedpercentageof][Specify percentage.]additionalmaterialforuse byowner inbuildingmaintenanceand repair.

PART2:PRODUCTS

2.01CompositeWall Panels

SpecifierNote:Retainarticlebelowfor proprietarymethodspecification.Addproductattributes;performancecharacteristics,materialstandardsanddescriptionsasapplicable.Useofsuchphrases as “orequal” or“orapprovedequal”orsimilarphrasesmaycauseambiguityinspecifications.Suchphrasesrequireverification(procedural,legalandregulatory)andassignmentofresponsibilityfordetermining“orequal”products.

A.Manufacturer:Nudo

1.Contact:1500 Taylor Avenue,Springfield,IL 62703;Telephone:(800) 826-4132,(217)528-5636;Fax:(217) 528-8722;E-mail:;website:

B.Proprietary Products/Systems:Composite wall ceilingpanels, includingthefollowing:

NūPoly™Wall Panels:

NūPoly:High-density polyethylene(HDPE)laminatedto plywoodorOSB substrateTexture:[Smooth, Pebbled, Quadripple,Moroccan,Haircell]

Substrate: [Plywood,OrientedStrandBoard(OSB)]Thickness: [0.375", 0.420",0.500", 0.625", 0.700" ]

Fire-RatingClass: C

Color:[Specifystandardand/orcustom colors as availableforproduct] [StandardFinish: Black(806), CharcoalGray (710),Beige(293), White (050)]

Size: [Specifysize, orasindicatedondrawings.] [4feet × 8feet (1.2× 2.4m)] [4feet × 10feet (1.2 ×3.0m)][4feet x12feet(1.2x3.6m).(largersizes availablethroughspecialorder.)

Physical Properties: / 1) / FlexuralStrength(ASTM D790):7,897lbf/in2.
2) / FlexuralModulus(ASTM D790):853,630psi.
3) / TensileStrength(ASTM D638):4,680 psi.
4) / BarcolHardness (ASTM D2583):--
5) / IzodImpact (ASTM D256):5.56ft-lb/in.
6) / SurfaceBurningCharacteristics (ASTM E84): ClassC.

2.02ProductSubstitutions

Substitutions:Nosubstitutionspermitted.

2.03Accessories

SpecifierNote:Specifysubordinateorsecondaryitemsthataidandassistprimaryproductsspecifiedaboveorarenecessaryforpreparationorinstallationofthoseitems.Specifymethodofjointseam treatmentbelowunderInstallation.

SpecifierNote:Paragraphsbelowlistproprietarydurable,decorativewall panelproductsofferedbyNudo.Selectandretainproductcharacteristicsrequired;deletecharacteristicsnotrequired.Refertomanufacturer’sproductdataorotherpublicationsformoreinformation.

Moldings:[SpecifycoordinatingPVC(polyvinylchloride)molding(s)] [Specify colorasavailableforproduct ][SpecifyAluminumcoordinatingmoldings ] [Specifycolor]

Rivets:[Specify optionalrivets incomplimentary colors (by colornameandnumber) inareaswheretherearelargefluctuationsintemperatureand/orhumidity, wherethesubstrateis unusually uneven,andin all lowtemperatureorcoldstorageapplications ]

PART3:EXECUTION

3.01Manufacturer'sInstructions

A.Adhesive: Providepaneladhesiveasrecommendedby panelmanufacturer.

B.TrimandSeam Treatment:

1.Manufacturer: Acceptabletopanel manufacturer.

2.ManufacturerDesignation: [Cornermolding] [Divisionbar] [Cap] [Specifymanufacturerdesignation.].

SpecifierNote:Retainoneofthreesubparagraphsbelowtosuitprojectrequirements.

3.MaterialandColor:Colormatchedacryliclatexcaulk.

4.MaterialandColor: [Aluminum moldings ] [Specifycolor]

5.MaterialandColor: [StandardPVCMoldings] [Specifycolor]

C.Fasteners: Provideappropriatefastenersandaccessories asrequired to properly complete installation.

3.03Preparation

A.Comply withtheinstructionsandrecommendations of thedurable,decorativewallpanel manufacturer.

SpecifierNote:Specifyactionstophysicallydeterminethatconditionsareacceptabletoreceiveprimaryproductsofthesection.

SiteVerificationofConditions: Verify substrateconditions, whichhavebeenpreviously installedunderothersections, are acceptableforproduct installationin accordancewithmanufacturer’s instructions. Verifythat siteconditionsareacceptableforinstallationofdurable, decorative wallpanels. Examineback-upsurfaces todeterminethat corners areplumbandstraight,surfacesaresmooth,uniform, cleanand freefromforeignmatter,nails arecountersunk andjoints andcracks arefilledflushandsmoothwiththeadjoiningsurface. Donot proceedwithinstallationofdurable,decorativewallpanelsuntil unacceptableconditions arecorrected.

3.04Installation

A.General:Priortoinstallingpanels,removepackagingandallowpanels to acclimate to roomtemperatureandhumidity forat least48hours.

Wallsubstratemustbedry and freefromdirt, dust, greaseandothercontaminants.Wallsmust beflat andeven.Removehighspotsandfill lowspotswithmaterialacceptableto panelmanufacturer.

Removewallpaper,solubleorloosepaintandotherforeignmatterthat might interferewithproperadhesivebond.Paintedwallsmust beprepared toadhesivemanufacturerspecificationsforproperadhesion.

SpecifierNote:Coordinatearticlebelowwithmanufacturer’srecommendedinstallationrequirements.Formoreinformationoninstallationrecommendations,visitmanufacturer’swebsiteat

B.General:

Inspect panelsforany defects immediately. Donot install panels ofunacceptablequality.Fieldcuttingofall wallsystemsshouldbeaccomplishedusing acircularsawwithfinetoothcarbideblade.

Positionpanel sothat thesawbladeenters thefinishedHPLsidefirst to avoidchippingordamage. Protect decorativelaminateface ofpanel by coveringworkarea,donotremoveprotectivewilluntilafterinstallation.

Followadhesivemanufacturer’s recommendations forappropriateheightof adhesivebeadleftbytrowelanddonotallowadhesive toskinover.When interiorpaneling is onanexteriorwallorwetarea,provide a barriersheetand/orfollowtheadhesivemanufacturer’sinstallationrecommendations forasecurebond.

C.Forinstallation tostuds orfurringstraps, fornon-composite wallsystemapplications, usemechanicalfastenersspaced

24inchesoncenter(O.C.)Furringstraps shallbenoless than18gauge3-1/2inches wide.Joint SeamTreatment: Installpanelsusingthefollowingmethod.

[Colormatchedacrylic latexcaulk].[Aluminum moldings].

[PVCmoldings].

D.InstallationUsing AluminumMoldingsorPVCTrims:

1.Start inthecorner.Markplumbline481/8inchesfromcorner.

2.Apply adhesivedirectlyto entireback of compositewallpanelusingcorrect trowelwith100%adhesivecoverageusingcrosshatchpattern.Applyadhesiveto within1/2inchofall edgesofpanel.

3.Slidepanelintomoldingandwithdraw[1/8 inchforPVCmoldings] [1/16inchforaluminum moldings] toprovideappropriategap.Alignwithplumbline.

4.Begin intopcornernearestmoldingwithlaminateroller, rollingdownandouttowardtheedgewithoutmolding.

5.Continuerollingdownandoutworkingacrosspanel away frompreviouslyinstalledpanelorinitialmolding.Removeall trappedair.

6.Installone-piecedivisionbarandcapsornext moldingby slidingontopanel.

7.Repeatprocess,working in onedirectionaroundroom.

8.Immediately removealladhesiveresidue. To remove, cleanwithnonabrasivecottonclothandwarmwater.Ifnecessary,use amildnonabrasivedetergent. Forcleanupwithsolventbasedadhesives, usemineral spiritsoracetonetoremoveresidue.

E.InstallationUsingCaulk:

1.Planpanel layout soseamsarenotdirectly overseamsof substrate.

2.Apply adhesivedirectlyto backof compositewallpanelwith100%adhesivecoverageusingcrosshatchpattern. Extendadhesive toall edgesof panel.

3.Installpanel.Placesix-penny finishingnails at 1/8inch(3.2mm)spacingagainst thepanel about2 feet(610mm)apart to holdpanels in placewhileadhesivesetsandprovideproperspacingforcolorcaulk.Continueinstallingpanels usingthis method, leavingnails in placeduringinstallation.

4.Removenails afteradhesivesets.

5.Placea narrowpieceofmaskingtapealongpaneledge fromtop tobottom,exactly at jointedge. Firmlyapply tape tobothpanels.

6.Fill1/8inch(3.2mm)gapbetweenthepanels withcaulk, makingsuregapis completelyfilled.

7.Tiltcaulkingtubeback fromverticalsothat tipof tubeadvances first in directionof travel.

8.Wet fingerandsmoothbeadifnecessary.

9.Removemaskingtapebeforebeadcures.Cleanoff excesscaulk withdampcloth.

10.Install cornermoldingsas described inmoldinginstructions.

3.05Cleaning

SpecifierNote:Specifythefinalactionsrequiredtocleaninstalledequipmentorothercompletedworktoproperlyfunctionorperform.CoordinatearticlebelowwithDivision01ExecutionRequirements(Cleaning)Section.

A.Cleanpanelsurfacesin compliancewithmanufacturer’s recommendations.

1.Use aclean, damp,nonabrasivecottonclothand amildliquiddetergentorhouseholdcleaner.

2.Rinsewithcleanwaterusingaclean,nonabrasivecottoncloth.

3.Dry panelswith asoft, cleannonabrasivecottoncloth.

4.Donotusecleaners containingacid,alkaliorsodiumhypochlorite.

3.06Protection

SpecifierNote:Specifyprovisionsforprotectingworkafterinstallationbutpriortoacceptancebytheowner.CoordinatearticlebelowwithDivision01ExecutionRequirementsSection.

A.Protectinstalledworkfromdamagedue tosubsequent constructionactivity onthesite.

—ENDOFSECTION—